Get complete information related to latest Spring Wire Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Spring Wire Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Spring Wire Tenders.
Tender For supply of "single lumen pressure injectable , taper free catheter: 4 fr. (1.81 mm od) x 50 cm , peel-away sheath: 5 fr. x 4" (10 cm) radiopaque over 5 fr. dilator spring-wire guide, nitinol, marked: .018" (0.46 mm) dia. x 17-3/4" (45 cm) (straight soft tip on one end - straight stiff tip on other) guidewire, marked: .018" (0.46 mm) dia. x 80 cm hydrophilic-coated nitinol with soft tip tungsten coil (ce 0120) introducer needle: echogenic 21 ga. x 2-3/4" (7 cm) tw syringe: 10 ml luer-lock skin protectant prep dust cap: non-vented second site adjustable hub: fastener second site adjustable hub: catheter clamp catheter trimmer safety scalpel: #11patient id card chart sticker patient information booklet checklist/clip sheet paper tape measure dressing: 1 catheter stabilization device, polyurethan catheter flowrate 5ml/sec [ warrantyperiod: 24 months after the date of delivery ]
Tender For tender for supply of sitc of air conditioner : : -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1391 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters auto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply. the indoor unit shall be suspended from the ceiling using threaded rods- including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required. , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealedscrollrotary compressor and eco friendly refrigerantinitial charge of refrigerantcondensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply. the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floorlaying and interconnection of standard-length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required. necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no. 1 2 , supply laying of 4c x 2.5 sqmm frls pvc insulated 1.1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1.2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required. , supply and fixing of 75mm dia minimum 1.8mm thickness pvc covering pipe using necessary bend collor clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25x25x5mm l angle frame including clamps bolts nuts vibrating dampers as required for mounting of outdoor unit. , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar to match for the surrounding as required after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling.
Tender For supply of compression spring for 4.5 kw alternator v belt tension device as per rdso old spring drg.no. skel 3940 sheet ii with springwire dia 14 mm and no. of coils 14 1/2 and en-47 material as per is-4454 and spring stiffness should be 2.8-3.2 kg/mm conforming to kel part no. a3225 (or) similar to drawing.