Get complete information related to latest Sprinkler Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Sprinkler Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Sprinkler Pump Tenders.
Tender For drilling of borewell and providing installation of power pump starter panelboard cable wire hdpe pipe hdpe tank stand sructure pvc pipeline valve standpost at ganesh mandir jewali ta lohara dist dharashiv
Tender For drilling of borewell and providing installation of power pump starter panelboard cable wire g i pipe hdpe tank stand sructure pvc pipeline valve standpost at chavan galli jewali ta lohara dist dharashiv
Tender For drilling of borewell and providing installation of power pump starter panelboard cable wire g i pipe hdpe tank stand sructure pvc pipeline valve standpost at maruti mandir jewali ta lohara dist dharashiv
Tender For supply, erection, testing and commissioning of pump 20 hp monoblock 30-45 mtrs. head, discharge 1100-2000 ltrs. per min, 80 mm non return valve, 80 mm sluice valve and 100 mm foot valve 1.6 pn, fully automatic star delta starter with wall mounting provision in ss sheet enclosure with digital volt and ammeter, single phasing preventer, protection features and heavy duty contactors of make l&t, abb or c&s or equivalent heavy gi bends 100 mm 1 nos., 80 mm - 1 no., heavy duty flanges, packing washers high tensile nut bolt make tvs/unbrako or equivalent b class gi pipe 100 mm control cable from pump to panel 4 core 16 sqmm cu cable foundation work, earthing, labor charge, commissioning charges, freight forwarding up to location. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of dol (direct on line ) starter power : 5 horsepower, 3 phase, 415v, 50 hz ac, relay range : 9-14a , mk1 type contactor rating, ac3 (a) : 15a, in built in contacts 1 no +1nc coil voltage : 360v, degree of protection : ip 54, in powder coated finish enclosure suitable use for submersible pump set 5/6 hp, 3 phase, 415v,50hz make : product similar to l&k mk1 ,crompton or similar . a certificate that material has been purchase from the oem/authorized dealer of oem along with the materials by the firm with guarantee/warranty certificate & test report. [ warranty period: 30 months after the date of delivery ]
Tender For repair and maint of overhead water tank, air compressor, irp, chemical dosing system, borewell, starter panel incl external pipeline network and connected items installed at various pump houses at af stn mohanbari
Tender For providing of custom bid for services - hiring of 06 nos of pump sets of minimum 250 mtr head and 2000gpm with 6600 v motor starter power cable suitable pontoon jetting hose of suitable size and pressure with flowmeter and other accessories for each pump set for d..
Tender For the detail of works includes:a. the tenderer shall carryout the following works during annual maintenance contract period along with the servicing of the diesel generator set.1. general checkup & preventive maintenance and to fill up preventive checkup schedule as follows:a) check lube oil level and conditioning of lube oil, top up/refill if required.b) the oil filters shall be replaced whenever oil is changed.c) the air filters shall be cleaned periodically with compressed air, check batteries and top up the distilled water if required.d) check functioning of changing alternator.e) engine safety viz. high water temperature gauge, oil temperature gauge and high speed gauge shall be checked for their functions and repaired/replaced if required.f) coolant level and conditioning of coolant shall be checked and refilled if required.g) check fan and alternator drive belts and tightened if required.h) the governor shall be checked and tuned for proper functioning.i) check for leaks if any and shall be rectified.j) check reports shall be submitted every month/every breakdown calls.2. checking and servicing of engine for smooth running, its unusual sound and color of smoke and exhaust and set it right in case of deviations.3. checking and repairing and leakage of fuel, lubricating oil and coolant.4. cleaning and changing of air filters as per requirement.5. setting of valves tappets whenever required.6. checking and repairing of accessories drive, turbo charger and crankshaft endplay whenever required.7. checking of alignment of engine & alternator as per requirement.8. checking of throttle control and its setting.9. checking of instrument panel including replacement as and when required.10. checking of rotating diodes assembly in brushless alternator including replacement as and when required.11. checking of wiring system and repairing/replacement as and when required.12. repair and maintenance of relays including contractors in control panel.13. checking of battery terminal and de-sulphating.14. diagnosis of faults in engine and alternator and its rectification.15. breakdown calls to be attended on priority within 6 hrs.16. providing spare avrs, self-starter and accessories, free of charge, if the repair/overhaul/replacement is expected to be taken in more than two days.17. checking/repair/adjustment/replacement/servicing shall be carried under annual maintenance contract except cost of component/parts to be replaced due to wear & tear.18. the firm should undertake to arrange genuine spares of the diesel engine, alternator and amf panel as and when required within two working days.19. the tenderer’s service engineer shall visit the site for attending the generator sets not less than twelve times during the contract period (minimum once in a month) and shall inspect the generator set thoroughly. each visit shall take place during 1st week of each month.20. the tenderer’s service engineer shall visit once in two month for checking of electrical side viz. alternator, amf control panel, if any.21. the engine shall be run on no load or at available load, and should be checked for any leakage and abnormal noise. if any such abnormality noticed shall be diagnosed and remedial action shall be taken.22. standard check list:a) replace minor parts (i.e hoses and filters etc) sub-assemblies as and when required.b) service engineers during the visit will report on the performance or any other abnormality and inform parts requirement. he shall also submit the report on work done and recommendations as well as spare parts required.c) attend emergency call on priority (usually same day). however, if the engineer is required or any particular date and time, it would be the responsibility of the customer to intimate the contractor in advance.d) major overhauling/ top overhauling / pt pump & injector calibration /replacement of major parts/ rewinding of alternator or repairs or breakdown of the diesel generator set are to be charge
Tender For . clear water pumping machinery at 10 mld wt a. two nos. centrifugal pump with motor discharge 342.6 m³/hr (95.16 lps) head 76 m b. including star delta starter 2 incomer 2 and 3 no outgoing (l&t,abb, simens) foundation, pipes, with specials, control panel, sluice valve(inlet & outlet) ,non return valves(outlet) 2 , aluminium armoured cable 240 sqmm 3.5 core, coper cable 70 sqmm single core, earthing (each pumps motor),pressure gauging ,tools, spares and lifting arrangement (10 to 32 no. and 24 inch pipe range, nose playar, player hd)