Web Analytics Made Easy - StatCounter

Ss Bench Tenders

Get complete information related to latest Ss Bench Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ss Bench Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ss Bench Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Co-operative

CTN :45067683 Due date: 12 May, 202612 May, 2026 3.50 Lacs
Tender For supply of vault (strong room) door as per is 11188 (q2)

CTN :44477651 Due date: 18 May, 202618 May, 2026 NA
Tender For corrigendum : supply of establishment of cyber range g g - compute nodes , gpu_ai accelerator cluster , hot nvme storage tier , worm hsm forensic vault , core spine switch , leaf switches , tap_grid packet capture , soc fusion and analytics servers , data diode , soc command center , r3 rf_sdr kits , i3 hil racks , t3 ai_lm simulation mlops , range conductor , darkweb intel platform , faraday cage rf isolation , physical security , integration cabling , 1st year critical spares , documentation and training , siem appliance , airgapped , usb control over ip , devlab tools, attack research kit , layer 2 switches , desktop computer_ work station , wifi router , malware sandbox cluster , security and assessment testing tool , development lab tool , scada simulation system , ups 30 kva with batteries , ups 50 kva with batteries , raised platform , wooden panelling and glass partition works , air conditioner , smart rack , utp cable roll , structured cabling work , earthing , display unit , furniture , data wall with controller , interactive panel , installation, commissioning and training , provision of 05 _ resident engginers ) /bid number : gem/2026/b/7127150 * /dated: 16-03-2026 & & / bid document 1 / 44

Central Government And Public Sector

CTN :45034478 Due date: 20 May, 202620 May, 2026 NA
Tender For tender for supply of radiation resistant cctv camera : : - type-ii (color ccd/cmos , 100m rad) radiation resistant camera head along with radiation resistant pan & tilt unit and mounting brackets. as per attached annexure-1 , corrigendum annexure-2 and annexure-3. , cabling system to transmit signals form vault cameras to ccu system which includes camera to ccu radiation resistant composite cable of 300 meters with 6 sets of cable connectors and applicable power cables as per annexure-1 , corrigendum annexure-2 and annexure-3. , field camera control unit and its racking system which includes 2 no. of camera control unit sub rack & 6 sets of camera control unit (ccu) cards (3 to be installed in field and 3 to be kept as spare for future ) as per annexure-1 , corrigendum annexure-2 and annexure-3 or equivalent sub rack system as per annexure-1 , corrigendum annexure-2 and annexure-3. , setup to convert ccu signals to optical signals which should include 3 no. of fiber optic transmitter and receiver set (capable of 4 camera system) and 6 no. of fiber patch cords , single mode , simpex and 3 no. of light interface unit 12 port , as per annexure-1 , corrigendum annexure-2 and annexure-3. , type-vi (color ccd/cmos sensor , non rr auto dome camera) with mounting brackets as per annexure-1 , corrigendum annexure-2 and annexure-3. , mechanism to transmit signal from non radiation resistant camera including , poe power supply for non-rr ptz camera (6 no.) field jb /rack in ss material for non-rr ptz camera (2 no.) liu 6 port , din rail mountable for non radiation resistant ptz camera (3 no.) din rail 8 port un-managed network switches (3 no.). 4 no. of fiber patch cords , single mode , duplex for non-radiation resistant ptz camera or equivalent as per annexure-1 , corrigendum annexure-2 and annexure-3. , mechanism for receiving signal at control room including light interface unit 24 port , rack mount (2 no.) and network video encoder (minimum 16-channel) along with accessories for intra-panel connections (2 no.) and 24 port un-managed network switches or equivalent (2 no.) , 4 no. of fiber patch cords , single mode , duplex as per annexure-1 , corrigendum annexure-2 and annexure-3. , recording and monitoring pc as per annexure-1 , corrigendum annexure-2 and annexure-3. , joystick suitable for mounting on control room panel cutout as per panel drawing as per annexure-1 , corrigendum annexure-2 and annexure-3. , 21 inch led backlit led color monitor as per annexure-1 , corrigendum annexure-2 and annexure-3. , video monitoring software setup as per annexure-1 , corrigendum annexure-2 and annexure-3 for minimum 9 camera. , mobile dolly consisting of camera control unit (ccu) , encoder , switch , joystick , engineering laptop with 15-inch to 17-inch screen , video management software for one camera , connection cables etc and their cabling as per annexure-1 , corrigendum annexure-2 and annexure-3. , control panel/rack 42u/ 27u setup for racking all instruments of cctv at control room as per annexure-1 , corrigendum annexure-2 and annexure-3. , cabling network optical fiber cable (6 core armored cable)-2000 meters twisted pair cable , rs485 , signal cable -200 meters unarmored coaxial cable rg59 -200 meters ethernet cable , cat-6 utp cable -610 meters video connector set -10 meters ethernet connectors rj-45 100 pieces conduit for cables 800 meters and other separate cables/ power cables/accessories required during installation one set of tool tackles for assembly/ disassembly/ of radiation resistant camera head viz. allen keys , lubricants , cable ties , loctite , heat sink , blank caps etc. 2 no. of control panel/rack size 27u setup for racking all instruments of cctv at field as per annexure-1 , corrigendum annexure-2 and annexure-3. as per annexure-1 , corrigendum annexure-2 and annexure-3 . , site installation & commissioning as per annexure-1 , corrigendum annexure-2 and annexure-3. , spare radiation resistance camera head s

Central Government And Public Sector

CTN :44802011 Due date: 07 May, 202607 May, 2026 NA
Tender For corrigendum : supply of cold end gasket for the fm service area viewing window as per the sketch kaps-1&2-21322 1 , hot end outer gasket for fm service rea viewing window as per the sketch-kaps-1&2- 21322 -2 , hot end inner gasket for fm service rea viewing window as per the sketch-kaps-1&2-21322-3 , spacer for fm vault and fm service rea viewing window as per the sketch- kaps-1&2-21322-sketch-4

Central Government/Public Sector

CTN :45003161 Due date: 05 May, 202605 May, 2026 NA
Tender For supply of vault (strong room) door as per is 11188 (q2)

Central Government/Public Sector

CTN :45014531 Due date: 07 May, 202607 May, 2026 NA
Tender For supply of vault (strong room) door as per is 11188 (q2)

Central Government / Public Sector

CTN :44960263 Due date: 01 May, 202601 May, 2026 NA
Tender For corrigendum : supply of vault (strong room) door as per is 11188 (q2)

Central Government/Public Sector

CTN :45026449 Due date: 07 May, 202607 May, 2026 NA
Tender For supply of vault (strong room) door as per is 11188 (q2)

Central Government/Public Sector

CTN :45026820 Due date: 07 May, 202607 May, 2026 NA
Tender For supply of vault (strong room) door as per is 11188 (q2)

Central Government And Public Sector

CTN :45023461 Due date: 19 May, 202619 May, 2026 72.25 Lacs
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - rawatbhata rajasthan site unit-3 and 4; assistance in cobalt element replacement for details refer boq; as per scope of work,repair, maintenance, and installation of plant/ systems/equipments (version 2) - rawatbhata rajasthan site unit-3 and 4; coolant channel in-service inspection assistance in fueling machine vault for details refer boq; as per scope of work,repair, maintenance, and installation of plant/ systems/equipments (version 2) - rawatbhata rajasthan site unit-3 and 4; assistance in barcis erection activity in fueling machine vault for details refer boq; as per scope of work,repair, maintenance, and installation of plant/ systems/equipments (version 2) - rawatbhata rajasthan site unit-3 and 4; zig saw panels removal and installation, installation is to be done as per satisfaction and checking b the fhu section for detail..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - rawatbhata rajas
 Loading, Please wait...

Connect us via What's Up