Get complete information related to latest Stage Lighting Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Stage Lighting Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Stage Lighting Tenders.
Tender For repairs to existing street lights & feeder pillar boxes and supply & replacing of existing 56nos 150w sv lamps with 90w led on existing single arm street light poles by deducting 20% cost of existing 150w sv luminaires at vakalapudi, kakinada district under iala for the year 2025-26
Tender For estimate no.112149 of 2025-26 prov. electrical installtion system supply arrangment, fire fighting, cctv survellience system, stagelighting, sound system, air condtioning system, for chhatrapati shahu maharaj smarak auditorium building at kolhapur.
Tender For corrigendum : tender for supply of led wall , led wall controller , wall mount fabrication & installation , encoder , decoder , windowing processor , ptz camera for audience , ptz presenter tracking camera , joystick camera controller , streaming/recording device. , av bridge , digital podium with screen , active line array speakers , active subwoofer speakers , active front fill speakers , active stage monitor speakers , laptop for podium , analog mixer , audio dsp with aec , usb audio interface , audio transreceiver , wired handheld mic , wireless handheld mic , wireless lapel mic , wireless head worn mic , uhf lpda antennas (pair) , uhf antenna distribution , gooseneck condenser mic , automation controller , wireless user interface touch panel , wired touch panel , network switch , pc with dual monitors , light automation system , cables & connectors , 42u av rack , stagelighting & integration , curtain & carpet , wireless presenter with dongle , installation & commissioning
Tender For supply of details description of specification for 100 watt led flood light - led rating in warm)/system wattage/rated power, led luminaire conformity to 15:10322/part 5/section 5/2012 latest and 15: 16107, (part 2/sec 1):2012, photo biological safety of leds used shall be as per 15:16108/2012 (exempt grou, types of led luminave as per the 15: 161070part-2/sec-11/2012, types of led modules as per the 25: 16103(part 2)/2012, led rating/system wattage/rated power, luminaire system efficacy bumen/watt), ingress protection (ip rating) as per 1 10322 (part 1): 1982 latest, mounting brackets fincluded, warranty for free replacement (in year), input operating voltage range and frequency, automatic higher cut off voltage above 300 volt, rated voltage, ac power factor at hill load, driver efficiency lin sage), total harmonics distortion (in lage), the total circut power shall not be more than 110 percent of the valve declared, by the manufacturer, led chip efficacy, colour temperature (+500), working life for led (minimum 50,000 buming hours as per lm-80 report), coltur rendering index(cri), optic lenise materal (uv stabilued) (write na or without optic lense supply), heat sink should be die-cast aluminum along with sufficient heat sink fins to desipate heat effectively, capacitor shall be ratail for a temperature of 105 deg. ceblus or better, junction temperature, operating temperature range, operating humidity range, short circuit protection, overload protection, over voltage geutection, reverse polarity, high voltage test (1.5 kv for ane minute between napply terminats and body of the, unit), insulation resistance between earth and current carrying part, the luminaire shad be protected against surges and transients (internal), the luminaire shall be protected against surges and transients of >/1kv, (external, the luminaires casing/housing (single piece housing) shall be pressure de catted, aluminum alloy with higher thermal.conductivity, the lummaire body must be corrosion resistant epoxy powder couted, all fasteners must be of stainless steel, the entire housing (both led section and driver section) shall be dust and water proof having ip 66 protection as per 15:10322 (part 11:1987 latest, luminaries light transparency should be of toughened glass, toughened transparent glass cover thickness, toughened glass shall not get discolored shall not suffer degration due to heat and agning within warranty period, number of electronic control gest (power sanoles), driver components shall be industrial grade or above, pci shall be fre grade minimum 0.8 to 1.0 mm thick or mom, the luminaires works on single phase three wires system (phase, neutral and, earth, suitable connector shall be provided for led connection between driver output, and led, length of st marked three cors wire (shall be provided along with supply of, materiall, ught source, manufactures name and and brand on the aluminium die cast body, manufacturer's name, model number, serial number, date of manufactiare (month-year), and int number as identification mark inside each unit and the outside of each packaging box, the operation characteristics voltage and power be marked inside of each led, system must have emi/emc compliance as applicable (test reports shall be furnish on demand by buyer/consignee)
Tender For repair maintenance of stagelighting and stage furnishing equipments in auditorium at rbcc president estate rashtrapati bhavan new delhisubwork/packages:replacement of existing halogen stage light fitting and accessories