Get complete information related to latest Stanchion Fitting Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Stanchion Fitting Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Stanchion Fitting Tenders.
Tender For supply and installation of electrical and mechanical equipment of tubewell at k block edmc flat sunder nagri and d block mcd flat nand nagari. (re-invite) - supply and installation of electrical and mechanical equipment of tubewell at k block edmc flat sunder nagri & d block mcd flat nand nagari by carrying out following works:- dismantling/lifting of tubewells with the help of gas cutter and heavy manual labour., supply of pvc insulated sheathed copper conductor cable for submersible pump motor of size 6mmsqx3core make :- finolex/ havells/ grandlay/djb approved make, supply of 80 mm dia d/f g.i pipe in b class as per isi 3 mtr long complete with cutting flange for submersible cable and support welded. make :- jindal/ tata., supply of tail piece medium class 0.5 mtr long including one end flanged and other end threaded of 80 mm dia., supply of 80 mm dia g.i bend with both side flanged welded, s/o m.s. clamp of m.s. strip 8mm thick duly hole for holding the pipe of 80 mm dia with nut bolt and washer, s/o m.s bore cover made out of m.s. plate suitable for 12" dia bore complete with suitable hole for pssing the 80mm dia gi pipe., s/o ci, d/f swing type nrv of 80mm dia make:- kirloskar/ ivc, s/o electronic dozing pump (4lph,5.5 kg) electrically controlled operated 230v, 50 hz, supply chemical grade tank of 100 ltrs with pipe make- milton roy/clomax, s/o nut bolts with washer of good quality of 1/2"x2" size, s/o rubber packing sheet synthetic 50% make :- jyoti / national, lighting arrangement including providing fixing1 no. tube light fitting 40 watt , 1 no. bulb point, 1 no. flood light on wall of room and also control board.etc.i/c electrification of room., labour charges for lowering the submersible pump set with all allied e&m equipments and fixing delivery line, valves, electronic dozing pump i/c hardware items as nut, bolts & washer i/c cartage to & fro., lt panel work of tubewell in ram nagar sps :- dismantling of lt panel with allied equipment with the help of skilled labour.., s/o power contactor 32 a. triple pole. make l &t/ havells, s/o front mounting add on aux contact block. make : havells/l&t, s/o three pole power contractor -25a cap. make l&t/ havells, s/o ampare meter (0-30a) 4 size squ. type. make l&t/ae, s/o voltmeter (0-500v) 4 size squ. type. make ae/l&t, s/o indicating lamp set for ryb phase. make l &t/ havells, s/o single phase preventor. make l&t/ minilac, s/o timer switch digital/anolog type. make l&t / havells, s/o over load relay thermal type 14-23 a. make l &t/ havells, s/o star delta timer on delay. make l&t /havells, s/o sp mcb 6a. make : l&t/havells, s/o 3p mcb 63. make : l&t/havells, push button 22.5mm(red / green), s/o 4p 63 amp elcb make : l&t/havells, changeover switch 63 amp., s/o 100a 3p mccb 25ka. with spreader make : havells/l&t., s/o rubber mat for electrical purpose of size 1mx2m and 3mm thick. make:- jyoti/ national, labour charges for repairing of lt panel with installation of above components i/c electric connection , testing and commissioning on load.
Tender For supply and installation of electrical and mechanical equipment of tubewell at tahirpur no.1 bps & nursery horticulture gtb enclave no.1. - supply and installation of electrical and mechanical equipment of tubewell at tahirpur no.1 bps & nursery horticulture gtb enclave no.1 by carrying out following works:- dismantling/lifting of tubewells with the help of gas cutter and heavy manual labour., supply of pvc insulated sheathed copper conductor cable for submersible pump motor of size 6mmsqx3core make :- finolex/ havells/ grandlay/djb approved make, supply of 80 mm dia d/f g.i pipe in b class as per isi 3 mtr long complete with cutting flange for submersible cable and support welded. make :- jindal/ tata., supply of tail piece medium class 0.5 mtr long including one end flanged and other end threaded of 80 mm dia., supply of 80 mm dia g.i bend with both side flanged welded, s/o m.s. clamp of m.s. strip 8mm thick duly hole for holding the pipe of 80 mm dia with nut bolt and washer, s/o m.s bore cover made out of m.s. plate suitable for 12" dia bore complete with suitable hole for pssing the 80mm dia gi pipe., s/o ci, d/f swing type nrv of 80mm dia make:- kirloskar/ ivc, s/o electronic dozing pump (4lph,5.5 kg) electrically controlled operated 230v, 50 hz, supply chemical grade tank of 100 ltrs with pipe make- milton roy/clomax, s/o nut bolts with washer of good quality of 1/2"x2" size, s/o rubber packing sheet synthetic 50% make :- jyoti / national, lighting arrangement including providing fixing1 no. tube light fitting 40 watt , 1 no. bulb point, 1 no. flood light on wall of room and also control board.etc.i/c electrification of room., labour charges for lowering the submersible pump set with all allied e&m equipments and fixing delivery line, valves, electronic dozing pump i/c hardware items as nut, bolts & washer i/c cartage to & fro., lt panel work of tubewell in ram nagar sps :-dismantling of lt panel with allied equipment with the help of skilled labour.., s/o power contactor 32 a. triple pole. make l &t/ havells, s/o front mounting add on aux contact block. make : havells/l&t, s/o three pole power contractor -25a cap. make l&t/ havells, s/o ampare meter (0-30a) 4 size squ. type. make l&t/ae, s/o voltmeter (0-500v) 4 size squ. type. make ae/l&t, s/o indicating lamp set for ryb phase. make l &t/ havells, s/o single phase preventor. make l&t/ minilac, s/o timer switch digital/anolog type. make l&t / havells, s/o over load relay thermal type 14-23 a. make l &t/ havells, s/o star delta timer on delay. make l&t /havells, s/o sp mcb 6a. make : l&t/havells, s/o 3p mcb 63. make : l&t/havells, push button 22.5mm(red / green), s/o 4p 63 amp elcb make : l&t/havells, changeover switch 63 amp., s/o 100a 3p mccb 25ka. with spreader make : havells/l&t., s/o rubber mat for electrical purpose of size 1mx2m and 3mm thick. make:- jyoti/ national, labour charges for repairing of lt panel with installation of above components i/c electric connection , testing and commissioning on load.
Tender For purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp frequency: 0.00001 t
Tender For bid to ras supply of augmentation of designated online exam centre at ins angre d d - wooden flush door of 35 mm block board with all necessary hardware fittings complete brand marine plywood century laminate royal crown , providing and fixing outdoor half wooden partition with aluminium framing and 12 mm prelame hdmr sheet on both the sides complete brand marine plywood century laminate royal crown , working desk made of marine ply finished in 1 point 5 mm thick laminate of royal crown with all hardware fittings included brand marine plywood , working desk refurbishment made of marine ply finished in 1 point 5 mm thick laminate of royal crown with all hardware fittings included brand marine plywood , chairs made of pu foam cushion sub body of plastic and finish material fabric , outside storage is made out of 19 mm marine plywood finished in 1 point 5 mm laminate with all hardware fitting necessary brand marine plywood , providing and fixing polyvinyl flooring of 1 point 5 mm thick flexible flooring of wooden texture fixed with adhesive in brick pattern of properties scratch proof water proof and durable material , 1 point 5 sq mm wiring , 2 point 5 sq mm wiring , 5 by 15 amp plug point each board consists 2 plug points , ac plug point , switch boards 66 desk x 2 boards each , 2 ft x 2 ft ceiling light , shifting of ups with wooden cabinet size 3 point 5 ft x 4 ft , network cabling of 60 plus 6 nodes
Tender For supply of non contact surface water velocity radar sensor and radar level sensor as per the technical specifications , data logger with all accessories as per technical specifications , dual sim based gsm and gprs upgraded modem with all accessories as per the technical specifications , solar panel with all connector cables and conduit as per the technical specifications , battery charger regulator with all interconnecting connectors cables for dcp as per the technical specifications , nema 4x or better enclosure box to suit master unit equipment with locking facility and other fitting and fixtures complete as per the technical specifications , other ancillary equipment fittings required for mounting earthling lightening arrestor with all connectors cables and conduit for cables sensor mount complete as per the technical specifications , installation testing and commissioning of discharge measurement system data logger data collection platform dcp with onsite data display system necessary software hardware, ancillaries equipment etc , transportation of the discharge measurement system along with all accessories at designated locations specified under this contract and as per the technical specifications