Get complete information related to latest Starter Box Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Starter Box Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Starter Box Tenders.
Tender For supply of filter , supply- ac and ventilation system- air intake louver , supply- ac and ventilation system- gravity damper , supply- ac and ventilation system- axial flow supply fans- 5500 cmh , supply- ac and ventilation system- axial flow exhaust fans with flp motor -7500 cmh , spares- ac and ventilation system -v-belt for ahu blower of each type , spares- ac and ventilation system -ahu blower bearings of each type , spares- ac and ventilation system -blower motor bearing for ahu , spares- ac and ventilation system -pre filter for ahu , spares- ac and ventilation system -fine filter for ahu , spares- ac and ventilation system -relative humidity sensors , spares- ac and ventilation system - geyserstat , spares-ac and ventilation system- local humidity temperature indicators , etc- ac and ventilation system- air cooled dx type condensing unit- minimum 33 tr actual capacity , etc- ac and ventilation system- air handling unit- ahu , etc- ac and ventilation system- fresh air fan assembly , etc- ac and ventilation system- split ac unit - 2 tr , etc- ac and ventilation system- strip heaters , etc- ac and ventilation system- pan humidifier , etc- ac and ventilation system- copper refrigerant piping- suction line , etc- ac and ventilation system- copper refrigerant piping-liquid line , etc- ac and ventilation system- refrigerant gas , etc- ac and ventilation system- gss duct sheet-24 g- air conditioning system , etc- ac and ventilation system- gss duct sheet-22 g- air conditioning system , etc- ac and ventilation system- gss duct sheet- 20 g- air conditioning system , etc- ac and ventilation system-gss duct sheet- 18 g- air conditioning system , etc- ac and ventilation system-non return damper , etc- ac and ventilation system-volume control damper , etc- ac and ventilation system- fire damper , etc- ac and ventilation system- motorised actuator for fire damper , etc- ac and ventilation system- grills diffusers , etc- ac and ventilation system- accoustic insulation , etc- ac and ventilation system- thermal insulation , etc- ac and ventilation system- dp switch , etc- ac and ventilation system- air flow switch , etc- ac and ventilation system- temperature cum rh sensor , etc- ac and ventilation system- fine filter , etc- ac and ventilation system- air intake louver , etc- ac and ventilation system-gravity damper , etc- ac and ventilation system- axial flow etc fans- 5500 cmh , etc- ac and ventilation system- axial flow exhaust fans with flp motor -7500 cmh , etc- ac and ventilation system-cable laying and termination alonwith lugs glands and any other accessories
Tender For supply, installation, commissioning and wiring for industrial hot air oven with replacement i- thermal digital temperature controller, 25a, output 24v to 480v ac and input 4-32/4-16 ma two way bidir ectional switch along with red and yellow indicator of size 15 mm, 24v capacity with compete rewiring of s ize 2.5 sqmm copper cable conforming to is: 1554 (part 1): 1988 or latest. [ warranty period: 30 months after the date of delivery ]
Tender For electric cabling service - 3 phase heavy duty electric wiring xlpe insulated working voltage form 415 v to 11 kv as per is 1554 along with associated items and civil work as per schedule of work attached; copper and aluminium coth conductor material as per schedule of work-1 supply, laying and testing cable xlpe insulated ,screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sq mm 3 1/2 core. rm 280 2 excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, or for shafts, wells, cesspits, manholes, pier holes, etc. and not exceeding 10 sqm on plan and getting out in soft /loose soil complete all as specified and as directed cum 60.75 3 returning filling including spreading leveling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and as directed. cum 60.22 4 removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. cum 0.53 5 supply and laying ldpe pipes 50 mm dia with all fitting ,laid in ground for crossing the cables across the road by cutting existing road , under floor ,wall by cutting existing floor and making good the road /floor and wall surface after laying of pipe . rm 270 6 cement concrete 1:3:6 type c-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete for making foundation for mounting flood light /bollard light fitting/finishing of roads/floors etc . cum 4.05 7 m &l for cutting of road /floor surface 30cm girth, up 45 cm width for croosing the pipe line /laying of cable acroos the road all as specified and directed. rm 30 8 s & f distribution boards epoxy powder coated tp & n (vtpn mccb db) 8 way ,415 volts ,fabricated from minimum 1.6 mm thick crca sheet and fixed/ flush to wall and suitable for universal mounting with 250 amps fully insulated copper bus bar for each phase and 02 neutral shrouded bar ,2 earth bar and cable tie for cable management with reversible door for ip-43 db,s protection, suitable for fixing fp mccb 100/125 amps as incomer complete all as specified and directed. note: suitable mccb and outgoing mcbs will be measured separately under relevant items of this schedule each 1 9 s & f mccb ,4 pole 100 a , 415 volts with rupturing capacity 16 ka with thermal-magnetic release and adjustable overload setting of following capacity complete all as directed. each 1 10 s & f bus bar chamber with 4 nos copper busbar 150 amps including mccb 100a 16ka 415 volts each 1 11 s & f sub main wiring with 4x16 sqmm +1 x 10 sqmm run pvc insulated unsheathed frlsh cable 1100 volt grade, with multi stranded copper conductor drawing in concealed pvc conduit not less than 25mm dia complete all as specified and directed. rm 50 12 s & f sub main wiring with 2x4 sqmm +1 x 4 sqmm run pvc insulated unsheathed frlsh cable 1100 volt grade, with multi stranded copper conductor drawing in concealed pvc conduit not less than 25mm dia complete all as specified and directed. rm 200 13 s & f modular rectangular block for mounting,modular switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175mm x 175 mm and 50 mm deep each 25 14 supply and fix modular switch 1 way 16a, 1 module with indicator lamp each 25 15 supply and fix modular socket 6a/16a, 2/3 pin combined 2 module each 25 16 material and labour for earthing with galvanised steel earth plate electrode 60cmx60cmx 6mm thick burried directly in ground (earth pit not less than2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 32 x 6 gi strip by means of nuts,bolts,check nuts & washers of galvanized iron or steel,protected by 15mm bore light grade galvanised iron pipe and connected to
Tender For tender for supply of 3000025013 emerson oxygen analyzer spares - o2 cell and heater assembly for ocx-8800 , part no 5r10190g02 , tag no ai417001 or 2 and ai424004 or 5 or 6 or 7 , heater insulator , mica for ocx-8800 , part no 6p00177h01 , tag no ai417001 or 2 and ai424004 or 5 or 6 or 7 , coe insulator for ocx-8800 , part no 1a99786h01 , tag no ai417001 or 2 and ai424004 or 5 or 6 or 7 , thermal switch insulator for ocx-8800 , part no 9886a15h01 , tag no ai417001 or 2 and ai424004 or 5 or 6 or 7 , blowback filter , 20micron , stainless steel for ocx-8800 , part no oldp or n 5r10246h02 , newp or n 5r10246h06 , tag no ai417001 or 2 and ai424004 or 5 or 6 or 7 , o-ring for ocx-8800 , part no 1a98448h02 , tag no ai417001 or 2 and ai424004 or 5 or 6 or 7 , adaptor for ocx-8800 , part no 5r10247h01 , tag no ai417001 or 2 and ai424004 or 5 or 6 or 7 , tube sample , 18in , 457 mm 316 stainless steel for ocx-8800 , part no 5r10183h02 , tag no ai417001 or 2 and ai424004 or 5 or 6 or 7 , signal cable assembly , remote electronics , 150 ft 45m for ocx-8800 , part no 6a00147g06 , tag no ai417001 or 2 and ai424004 or 5 or 6 or 7 , hasteloy in situ filter , 10 micron , high temperature for ocx-8800 , part no 1a99762h03 , tag no ai417001 or 2 and ai424004 or 5 or 6 or 7 , electronics stack , hart for ocx-8800 , part no 6a00132g01 , tag no ai417001 or 2 and ai424004 or 5 or 6 or 7 , filter emi for ocx-8800 , part no 1a98467h01 , tag no ai417001 or 2 and ai424004 or 5 or 6 or 7 , heater strut asseembly for ocx-8800 , part no 5r10211g02 , tag no ai417001 or 2 and ai424004 or 5 or 6 or 7 , combustibales sensor replacement kit for ocx-8800 , part no 4851b46g03 , tag no ai417001 or 2 and ai424004 or 5 or 6 or 7 , cell replacement kit 18 inch ansi , oldp or n 4847b61g02 and 4847b61g26 new p or n 4847b61g27 , mdl oxt4c-2-0-0-0-1-4-3-1-0-0-0-2-0-0-0-0 , tag no at341004a or 2a , 3 heater strut assembly old p or n 3d39744g02 , new p or n 3d39645g02 , mdl oxt4c-2-0-0-0-1-4-3-1-0-0-0-2-0-0-0-0 , tag no at341004a or 2a , make emerson , loi module for oxymitter-4000 , p or n 6a00115g01 , mdl oxt4c-2-0-0-0-1-4-3-1-0-0-0-2-0-0-0-0 , tag at341004a or 2a , mott filter mott all inconel tube element seamless porous tube element with hex nipple connection porous od 1 or 2 inch open end connecti on 1 or 2inch npt male hex nipple porous lg 18 reference opposite end connection plain solid end cap media grade 0.5 , p or n , filter element mod. 7612-4-1 or 2-18-0.5-kbfd , c 20 inch
Tender For supply of spares for swas system - sample isolation valve ht , sample filter sepl make , safety relief valve make sepl , thermal shut off valve with contact make thermomega tech , main rotameter purge type sepl , rotameter purge type sepl , temperature gauge make mass , pressure gauge make mass , rtd sensor with 3m cable type duplex , back pressure regulator make sepl , grab sample valve 3 way ball valve make sepl , cation column duplex type make sepl , temperature controller , emerson make filter drier , expansion valve tjre 18 hw , rtd pt 100 type simplex , level controller , single phase failure for 3 phase model sm 301 make gic , smps 230 vac to 24 vdc 5a din rail mount make meanwell lutz , olr 10 16 a model number 3ua5500 2a , pressure switch hp lp cut out , pressure gauge mass psi dia 2 1 2 glycerine filled , pressure guage mass 30 to 260 psi dia 2 1 2 glycerine filled , baumer make temperature cb d 2 4nm zi 2c stem dial size 63 mm , honeywell make flow switch with contact power rating 230vac model no wfs 6000 , level indicator 1 2 bsp ss 304 , plc siemens make s7 200 series cpu st20 , simatic hmi ktp700 basic , part no 3ua50001e description olr around 2.5a to 4.0 a current make siemens , stream selector for 4 channel ss301 operating voltage 230 vac , pressure regulator diaphragm type make sepl , pressure reducer with built in valves vrts , sample cooler , 3 way ball valve , sample isolation valve lt valve , coolant flow indicator ss 316 1 2 npt f model no sepl cfi 12 ss , conductivity sensor model uv 6012 0.1 cond 34 make sepl bid number/ & ( * ) : gem/2025/b/6068085 dated/ + : 23-04-2025 bid document/ 3 3 1 / 45
Tender For bid to ras bid to ras repair and overhauling service - upgradation of gym interior of officers gym; interior design; yes; buyer premises: augmentation of interior designing for officers' gymanisum -ins vishw rma-1 false ceiling-providing and fixing suspended false ceiling of armstrong or equivalent (fine fissured micro look with silhouette grid) equivalent of size 600mm x 600mm at all levels fixed with channels & hanger rods & making cut outs for all led lights etc including all material, labour and transportation as per approved sample designs, drawings and specifications as directed by the officer in-charge. item includes dismantling of old ceiling and disposal of the malba. providing ducting after making necessary connections from the main duct . the work has to be executed in co-ordination with the air conditioning system agency and with the officers monitoring the ac system 2) wooden ceiling providing of faux beams in the ceiling as part of the design of the false ceiling. beam size shall be 8" x 8" as per texture and colour finalized . the installation has to be carried out maintaining the aesthetics of the area and as per design finalized including all material, labour, transportation as per approved sample designs, drawings and specifications as directed by the buyer 3) electrical wiring : providing & fixing of 25mm electrical conduits of make akg/polypack/setia or equivalent making chasing in walls & finishing it with plaster making it good for painting & pvc insulated copper wires of finolex/havells or equivalent as per approved samples, design, drawings, specifications & as directed by the buyer, item includes removal of the old wiring and disposal of the malba 4) light fixtures downlighters : providing & installation of led downlighters of 5000k of reputed brand jaguar/philips/legero/syska as per approved samples, design, drawings, specification and as directed by the buyer with testing and commissioning. item includes dismantling of old lights and buy back of old lights with fittings and disposal of all malba 5) track lights & spot lights spot lights : providing & installation of 9w cob lights of reputed brand jaguar/philips/legero/syska as per approved samples, design, drawings, specifications and as directed by the buyer 6) magnetic track lights : providing of suspended magnectic tracks of reputed brand philips/jaguar/ legero/syska or equivalent including 200w integrated power supply, trimless wall corner l jointer for magnetic track channel and hanging kit set. providing of 20w linear laser tiltable spotlight with a combination of cone pendant light as per approved samples, design, drawings, specifications and as directed by the buyer 7) switches/sockets & switch boards providing of switches sockets and all the switch boards of reputed brand i.e. schneider/norisys as per approved samples, design, specifications and as directed by the buyer 8) ceiling and wall painting cleaning and sanding of the surface of the ceiling and wall and application of 1st coat of oil base primer. upon drying of primer, application of 2 coats of birla wall putty. upon drying, sanding the surface to a smooth seamless finish and application of 2nd coat of oil base primer. upon dring of the primer application of 3 coats of emulsion of royale teflon finish as per approved samples, specifications and as directed by the buyer 9) wall panelling providing and fixing in position wall panelling at all heights with pvc wall panel/sheets (5-9mm thickness) of approved texture, design and patterns having nrc (noise reduction co-efficient) of 0.50 (minimum), light reflectance of 85% (minimum). non combustible fire performance as per bs:476 , humidity resistance of 100% , thermal conductivity <0.043 w/m k comprising of frame made in the wall from specially fabricated galvanized mild sheet 0.50mmthk pressed section (galvanizing @120grams per sqm including both sides) i.e. vertical studs of size 48 x 34 x 36 fixe
Tender For supply of spares for mine line make get end box geb pac bid - power plate chassis assly complete wit part no gebpwr , control plate chasis assy suitable for part no gebconrl , cover fixing bolt part no 000110a , current transformer 15va part no 120029 , ammeter part no am , on off rev isolator part no k4r , push button actuator part no 120022 , terminal bushing assy with brass termin part no t5 , copper stud with dmc insulator part no tic , test switch part no ts2c , thermal overload relay part no 120021 , glass fuse with holder part no bogf , split type terminal box part no tb13 , sealing box complete part no s1 , indicating lamp with pcb mounting part no lab9geb , aux contactor 220v ac part no boca2dn1229 , push button actuator for el test part no boes2 , potential transformer type d part no ds , hrc fuse part no bohrc160 , search and lockout relay part no lsk2000 , restrained type plug and socket complete part no 010000 , resistance part no 139geb , earth leakage relay 50 750 ma 750ma with part no elm7la , earth leakage relay 50 750ma 2a dual part no elm7dlas , core balance transformer part no cbt90m , core balance transformer part no cbt150m , pilot relay part no pru3 , single phasing preventor with module part no spp5cmsp , shunt trip assy 11 point 03 point 00 9 mine line part no 110300 , no volt coil assy under voltage coil as part no 110400a , no volt coilunder voltage coil part no 110402 , isolator assly k3 on off part no 050000 , dashpot cup part no 110106 , complete control wiring including pla r part no wr2a , micro switch part no 50502 , push button with spindle part no pbs