Web Analytics Made Easy - StatCounter

Static Energy Meter Tenders

Get complete information related to latest Static Energy Meter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Static Energy Meter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Static Energy Meter Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :39754309 Due date: 06 May, 202506 May, 2025 19.00 Crore
Tender For corrigendum : supply of single phase static energy meters with meter box

Corporations And Associations And Others

CTN :39841508 Due date: 01 May, 202501 May, 2025 58.40 Crore
Tender For corrigendum : whole current ac single phase two wire dlms compliant static energy meter (10-60a) of accuracy class 1.0 with communication facility with self locking type polycarbonate meter box

State Government

CTN :39984717 Due date: 18 Apr, 202518 Apr, 2025 NA
Tender For supply of following items for setting up measurement and instrumentation lab for 4 year b.tech in electrical engineering curriculum and application for university of calcutta. - experimental set-up for calibration of a wattmeter using dc potentiometer with following features/items:regulated power supply 2 volts, 100 ma to operate the potentiometer.calibrated electronic standard cell voltage 1.0186 volts.regulated power supply 0-5 volts/0.5 amps with milliammeter 0- 500ma for current coil of wattmeter.regulated high voltage power supply 0-250 dc volts with voltmeter 0-250 volts for pressure coil of wattmeter.a panel mounting wattmeter 0-125 watt is required to perform the experimentgalvanometer for null balance.a volt ratio box for measurement of higher voltage.complete circuit diagram with wattmeter connections to be provided on the front panel of the instrument.with standard accessories, experimental set-up for low resistance measurement using kelvin s double bridge with following features:range: 0.2 micro ohm to 11 ohms, with an accuracy of 0.05 %required accessories:spot reflecting galvanometer. dc source 10 a with one analog current meter. attachment of 1 meter length.brass clamp with terminals for zero setting. with standard accessories, experimental set up for unknown capacitance measurement using de-sauty s bridge with following specifications:source: sine wave signal of 1khz. the amplitude of ac switch indicating lamp is provided on the bakelite board. two sockets are to be provided for the output of ac signals.detector: for detecting small ac signals in the output, null detector is required as in-built with digital display.circuit diagram:the circuit layout on the board is to be provided out to facilitate convenient working. 4 or 5 mm socket required for making connection. features:r2 --- three decade resistance dials having value 10 1000, 10 100 and 10 10 ohmsr1 ---- single decade resistance dial having value 10 100 ohmsc1 ---- unknown capacitor.c2 ---- two fixed standard capacitors having value 0.01mfd 0.1mfd (loss free)with standard accessories, experimental set-up for calibration of a 1-phase watt-hour meter with following scopes: to adjust & calibrate a single-phase energy meter by direct loading method to adjust & calibrate a single-phase energy meter by comparing with a sub-standard meterspecifications: static energy meter single phase: under test (local) duly mounted, wired and terminated static energy meter single phase: sub-standard meter (isi mark) duly mounted, wired and terminated voltmeter: moving iron ac portable of class 1.0 accuracy and range 0 - 300 v ac ammeter: moving iron ac portable of class 1.0 accuracy and range 0 - 10 a ac wattmeter: dynamometer type ac single phase, multi-range with current coil 5 / 10 amp and potential coil 75 / 150 / 300 v ac variac: variable voltage transformer (portable table / floor mounting type with enclosure) input: 230v ac and output: 0 270v / 8 amp ac variable load: made up of 3 load resistors of 70 ohms / 700 w each duly mounted and connected / terminated to form different loads (35 to 210 ohms) as per external connections digital stop clock: portable with start / stop & reset operation set of necessary 4 mm spring loaded patch cords for interconnections detailed instruction manual supply to be connected: 230v, 1phase, 50 hz, ac mains, experimental set-up for calibration of a 3-phase watt hour meter with following specifications: to adjust & calibrate a three-phase energy meter by direct loading method to adjust & calibrate a three-phase energy meter by comparing with a sub-standard meterspecifications:static energy meter three phase: under test (local) duly mounted, wired and terminatedstatic energy meter three phase: sub-standard meter (isi mark) duly mounted, wired and terminatedvoltmeter: moving iron ac portable of class 1.0 accuracy and range 0 - 300 v acammeter: moving iron ac portable of class 1.0 accuracy and range 0 - 10 a acwattmeter:
 Loading, Please wait...

Connect us via What's Up