Get complete information related to latest Steel Tube Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Steel Tube Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Steel Tube Spares Tenders.
Tender For supply of t banner with zari regt crest , spur box , t stand metal steel , lancer penant with star and ashoka , lancer pipe col of regt with rings , lancer penant col of the regt , regt flag 6x4 with silken crest , national flagt 6ft by 4ft , name plate metal col of the regt , pagri complete , lancer pipe steel 10.5ft , brass table stand , zari table flag 10cm by 15cm , donga large , donga small , citation steel , citation golden
Tender For construction of tennis court with synthetic surface and accessories : : - constr of sub base of 4 inch thick pcc of size 120 ft x 60 ft with layer of 60 to 40 mm stone metal mixed with murum or rolling with 8 to 10 ton roller with bm 35 mm thick and seal coat 15 mm thick , providing 5 layer synthetic acrylic standard system consisting of one coat of acrylic primer followed with two layer of acrylic resurfacer and the final two coats are of acrylic colour , line marking as per itf standards alongwith white taxtured acrylic paint , 3 ft net posts made of ms pipe of 6 inch diameter set in concrete sleeves , standard 42 ft wide net doubles court made of braided polyethylene or polyester , 10 nos phiips led flood light 200 watt mounted on 10 nos pole and diameter of the pole 3 inch square ms pipe of height 13 ft and underground 3 ft and above ground 10 ft , wiring of led flood light on pole with 200 mtr and 2 core electric cable
Tender For corrigendum : supply of replacement and repair maint work of rpl no 12 c c - replacement of existing 04 x hinges of ramp as per sample inclusive all charges , replacement of existing ms iron beam and garder of ramp of front side of size 20 ft and thick 15 mm , repair and maint of ramp winch balancing problem and handle problem of pbs and sbs , replacement of existing 04 x ms iron air wind pipe of both side of size 2 ft 5 inch and 2 mm thick , replacement of existing 01 x fire hydrant valve and 1 x outlet valve as per sample , replacement of existing roof ms plate of sbs of master cabin of size 15 ft x 2 ft 4 inch and 3 mm thick and including ceiling remove and refixing , replacement of existing ms plate of port side near main engine of size 4 ft 4 inch x 3 ft 6 inch and thick 6 mm inclusive all charges. , replacement of existing ms plate of driver cabin bathroom of size 8 ft 4 inch x 3 ft and thick 6 mm and replacement of tile of driver cabin bathroom of size 5 ft 4 inch x 3 ft , supply and fixing of pvc pipe line connection from water tank to both side or bathroom and offr bathroom with kitchen of size l 185 ft, half dia and and , replacement of existing accelerator throttle of sbs and pbs as per existing specification with 20 mtr swr thick 4 mm , balancing, remetalling of existing sbs propeller fan with brass metal , replacement of rotary pump as per existing specification , replacement of existing 02 x transparent glasses of master cabin of size 24 inch x 18 inch and thick 3 mm inclusive all charges ) /bid number : gem/2025/b/6371738 * /dated: 22-06-2025 & & / bid document 1 / 13
Tender For state scheme (nabard)/25-26/barsoi/01 - construction of hl rcc bridge from ganjan to vibhor hat road at ch.-1.720km, earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. i) upto 3m depth, providing and constructing temporary island 8 m diameter for construction of pile foundation. assuming depth of water 4.0 m and height of island 4.5 m., dismantling of reinforced concrete pile head complete as per drqwing and technical specification, providing and laying of pcc m15 levelling course 150mm thick below the pile cap. ii. pcc grade m-15 (levelling course), r.c.c. grade m 35 in pile foundation complete as per dwg & tech specification. pile cap in rcc m-35, bored cast-in-situ m35 grade r.c.c. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. ii. 1200 mm dia, supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawings and technical specifications clauses 1000 and 1202, providing steel liner 6 mm thick as per detailed drawing., r.c.c. grade m-35 in substructure complete as per dwg & tech specification i) upto 5m height (using concrete mixer), r.c.c. grade m-35 in substructure complete as per dwg & tech specification ii) from 5m upto 10m height (using concrete mixer), r.c.c. grade m-40 in substructure complete as per dwg & tech specification ii) from 5m upto 10m height (using concrete mixer), supplying, fitting and placing hysd bar reinforcement (fe 500) in substructrue complete as per drawings and technical specification clauses 1002, 1005, 1010 & 1202, supplying, fitting and fixing in position true to line and level pot-ptfe bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, ptfe surface sliding against stainless steel mating surface, completre assembly to be of cast steel/fabricated structural steel, metal and elastomer elements to be as per irc: 83 part-i & ii respectively and other parts conforming to bs: 5400, section 9.1 & 9.2 and clause 2006 of morth specifications complete asper drawing and approved technical specifications., providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia ac pipe extending through the full width of the structures with slope of 1(v):20(h) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7, backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification clause 1204.3.8 i) sandy material, providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification clause 1204.3.8, providing and laying reinforced cement concrete in superstructure complete as per drawing and technical specifications clauses 800, 1205.4 and 1205.5 ii. rcc m-35, supplying, fitting and placing hysd bar reinforcement (fe 500) in superstructrue complete as per drawings and technical specification clauses 1002, 1010 & 1202, providing and laying cement concrete wearing course m30 grade including reinforcement complete as per drawing and technical specifications clauses 800 and 1206.3, provision of an reinforced cement concrete crash barrier at the bridge decks& approaches to bridge structures constructed with rein forced cement concrete with hysd r
Tender For (nabard)/25-26/samastipur/01 - construction of hl rcc bridge over shanti river in chakmahesshi panchayat near chakmaheshi dhala, earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.i) upto 3m depth, providing and laying of pcc m15 levelling course 100mm thick below the pile cap.ii. pcc grade m-15 (levelling course for pile cap), r.c.c. grade m 30 in pile foundation complete as per dwg & tech specification.pile cap in rcc m-30, bored cast-in-situ m35 grade r.c.c. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m.ii. 1200 mm dia, supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawings and technical specifications clauses 1000 and 1202, providing steel liner 10 mm thick for curbs and 6mm thick for steining of wells including fabricating and setting out as per detailed drawing, providing and constructing one span service road to reach island location from one pier location to another pier location including royality for earth @ rs. 225.00 per m for service road., carrying out load test on any pile as per standard procedure laid down in the is:2911 specification including construction of test cap, dismantling the cap after test and cleaning the site and maintaining complete records of load1.2 m dia pile, b) routine pile load test on pile for 1.5 times the design load specified in drawings1.2 m dia pile (2% of piles in total)., c) horizontal pile load test on pile for 1.5 times the design load specified in drawings1.2 m dia pile (2% of piles in total) ., substructure, r.c.c. grade m-30 in substructure complete as per dwg & tech specificationi) upto 5m height (using concrete mixer), ii) from 5m upto 10m height (using concrete mixer), r.c.c. grade m-35 in substructure complete as per dwg & tech specificationrcc m-35ii) from 5m upto 10m height (using concrete mixer), supplying, fitting and placing hysd bar reinforcement (fe 415) in substructrue complete as per drawings and technical specification clauses 1002, 1005, 1010 & 1202, supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia ac pipe extending through the full width of the structures with slope of 1(v):20(h) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7, backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification clause 1204.3.8 i) sandy material, providing and laying filter media with granular crushed aggregates (jhama metal) as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification clause 1204.3.8, superstructure, providing and laying reinforced cement concrete in superstructure complete as per drawing and technical specifications clauses 800, 1205.4 and 1205.5ii. rcc m-30, supplying, fitting and placing hysd bar reinforcement (fe 415) in superstructrue complete as per drawings and technical specification clauses 1002, 1010 & 1202, providing and laying cement concrete wearing course m 30 grade including reinforcement complete as per drawing and technical specifications clauses 800 and 1206.3,
Tender For mgsy/25-26/jhajha/01 - construction of rcc hl bridge on kiyajori se maharaidih, foundation, earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.i) upto 3m depth, providing and laying of pcc m15 levelling course 100mm thick below the pile cap.ii. pcc grade m-15 (levelling course for pile cap), r.c.c. grade m 30 in pile foundation complete as per dwg & tech specification.pile cap in rcc m-30, bored cast-in-situ m35 grade r.c.c. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m.ii. 1200 mm dia, supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawings and technical specifications clauses 1000 and 1202, providing steel liner 10 mm thick for curbs and 6mm thick for steining of wells including fabricating and setting out as per detailed drawing, providing and constructing temporary earth island (assuming depth of water 1.0 m and height of island to be 1.25 m including royality for earth @ rs. 5526.00 for each island.), providing and constructing one span service road to reach island location from one pier location to another pier location including royality for earth @ rs. 225.00 per m for service road., carrying out load test on any pile as per standard procedure laid down in the is:2911 specification including construction of test cap, dismantling the cap after test and cleaning the site and maintaining complete records of load1.2 m dia pile, b) routine pile load test on pile for 1.5 times the design load specified in drawings1.2 m dia pile (2% of piles in total)., c) horizontal pile load test on pile for 1.5 times the design load specified in drawings1.2 m dia pile (2% of piles in total) ., substructure, r.c.c. grade m-30 in substructure complete as per dwg & tech specificationi) upto 5m height (using concrete mixer), ii) from 5m upto 10m height (using concrete mixer), r.c.c. grade m-35 in substructure complete as per dwg & tech specificationii) from 5m upto 10m height (using concrete mixer), supplying, fitting and placing hysd bar reinforcement (fe 415) in substructrue complete as per drawings and technical specification clauses 1002, 1005, 1010 & 1202, supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia ac pipe extending through the full width of the structures with slope of 1(v):20(h) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7, backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification clause 1204.3.8 i) sandy material, providing and laying filter media with granular crushed aggregates (jhama metal) as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification clause 1204.3.8, superstructure, providing and laying reinforced cement concrete in superstructure complete as per drawing and technical specifications clauses 800, 1205.4 and 1205.5ii. rcc m-30, supplying, fitting and placing hysd bar reinforcement (fe 415) in superstructrue complete as per drawings and technical specification clauses 1002, 1010 & 1202, providing and laying cement con
Tender For mgsy/25-26/bhabhua/01 - name of work: construction of proposed hl rcc bridge on durgawati river at swar gadh of rampur block in the dist-kaimur(bhabhua), length- 111.60mfoundationexcavation for structuresearthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.i) upto 3m depth, providing and laying of pcc m15 levelling course 100mm thick below the pile cap.ii. pcc grade m-15 (levelling course for pile cap), r.c.c. grade m 35 in pile foundation complete as per dwg & tech specification.pile cap in rcc m-35 (using batching plant, transit mixer and concrete pump), bored cast-in-situ m35 grade r.c.c. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m.ii. 1200 mm dia (using batching plant, transit mixer and concrete pump), supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawings and technical specifications clauses 1000 and 1202, providing steel liner 10 mm thick for curbs and 6mm thick for steining of wells including fabricating and setting out as per detailed drawing, providing and constructing temporary earth island (assuming depth of water 1.0 m and height of island to be 1.25 m including royality for earth @ rs. 5526.00 for each island.), carrying out load test on any pile as per standard procedure laid down in the is:2911 specification including construction of test cap, dismantling the cap after test and cleaning the site and maintaining complete records of loada) initial load test on test pile for 2.5 times the design load specified in drawings1.2 m dia pile, b) routine pile load test on pile for 1.5 times the design load specified in drawings1.2 m dia pile (2% of piles in total)., c) horizontal pile load test on pile for 1.5 times the design load specified in drawings1.2 m dia pile (2% of piles in total) ., substructurer.c.c. grade m-30 in substructure complete as per dwg & tech specificationrcc m-30 (using batching plant, transit mixer and concrete pump)i) upto 5m height (using batching plant, transit mixer and concrete pump), ii) from 5m upto 10m height (using batching plant, transit mixer and concrete pump), supplying, fitting and placing hysd bar reinforcement (fe 415) in substructrue complete as per drawings and technical specification clauses 1002, 1005, 1010 & 1202, supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia ac pipe extending through the full width of the structures with slope of 1(v):20(h) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7, backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification clause 1204.3.8 i) sandy material, providing and laying filter media with granular crushed aggregates (jhama metal) as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification clause 1204.3.8, superstructureproviding and laying reinforced cement concrete in superstructure complete as per drawing and technical specifications clauses 800, 1205.4 and 1205.5ii. rcc m-30 (using batching plant, transit mixer and concrete pump), supplying, fitting and p