Get complete information related to latest Stirrer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Stirrer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Stirrer Tenders.
Tender For supply of small equipments and consumables to chemistry research center, gec ramanagara. - exhaust fume hood (fume hood), pin on disc wear testing machine, whatman filter paper (no.41), ups for laboratory, laboratory refrigerator (small fridge), water distillation unit (single distillation), hydrothermal bomb (teflon lined autoclave), laboratory centrifuge machine & tubes, digital ultrasonic bath (ultrasonicator)- rectangular, magnetic stirrer (and bits) with hot plate
Tender For rate contract for the procurement of consumables/non-consumables for the department of physiology - battery rechargeable 3000mah - aa 1.5v, battery rechargeable 900mah- aaa 1.5v, blotting paper - regular (filter paper) 60 x 60 cm, clamp electrodes for mortara eli 250 - one set should consist of 4 colors - black, red, yellow and green, corrugated tube antistatic :105 cm x 22 mm ( spares for student‘s spirometer), crocodile clip with plastic shield, ecg patient cable for mortara eli 250 - one piece cable with non replaceable banana end connectors and 15 pin d- sub connector, heparinized capillary tubes (100mm length, 0.5mm internal diameter) - pack size - 100 nos/pack, ishihara chart book for testing colour blindness with interpretation, jager‘s chart for near vision, "kymograph drum paper -measurements: length - 21 inches or more, width - 6 inches", lancets (sterile disposable) (pack of 200 nos), "micro capillary tube for clotting time 15cm in length& 0.1 mm in diameter without anti-coagulant - pack size - 100 nos/pack", microscopic oil (pack of 500 ml), mouthpiece disposable for vitellometer samples neded, near vision test type book sample needed, neubauer chamber with improved neubauer ruling (sample should be provided, if not will be subjected to rejection), pen torch light (runs with 2 aa batteries), perimetry charts, plastic dropper (diameter - 3 mm, total length - 8 cm, tube length - 6 cm), plastic tailor's measuring tape - 60 inches or 152 cms, power cord for monocular microscopes, pre gel electrods, "rbc pipette (german make)make: rohem'/riviera'/bioplus'/sunbeem (sample to be submitted, if not will be subjected to rejection)", sahli's heamoglobin pipette, sahli's heamoglobin stirrer, sahli's heamoglobin tube, silicon tubing - inner diameter - 10 mm, outer diameter - 6 mm for use in sthethography, snellen‘s chart for visual acuity with english alphabets, tissue paper roll - 100grm, wbc pipette (german make) make: rohem'/riviera'/bioplus'/sunbeem (sample to be submitted, if not will be subjected to rejection), whatman filter paper no. 1- pack size - 100 nos/pack, equipments / small instruments, "adjustable height scale (wall mountable: 30-200 cm, resolution: 0.1 cm, graduations in mm) (sample to be demonstrated. otherwise subject to rejection).warranty 1 year", "algometer1. cylindrical metal body with one end consisting of a sliding metal slab with graduations marked 0, 1, 2, 3, 4 kgs2. one end is hand held and other is pressed on the body3. sample to be demonstrated", aneroid sphygmomanometer, artery forceps 5 â½" curved, artery forceps 5 â½" straight, "automated blood pressure monitor with arm cuffs of 3 sizes:1. upper arm cuff - i) pediatric sizeii) adult sizeiii) extralarge adult sizeto be validated by world hypertension league.warranty 1 year", "centrifuge apparatus:1. maximum rotational speed: 6000 rpm or above,2. maximum relative centrifugal force: 5070 g or above,3. angle head'/swing out heads for holding test tubes4. max capacity: 24 x 15 ml, safety lid interlock to prevent coveropening during centrifuge. warranty 2 years", "centrifuge• digital speed indicator• number of slots 8• rotator capacity 8x15ml• speed 5000rpm• warranty 1 year• step less speed regulator.• safety lid interlock during centrifugation.• digital speed meter and digital countdown timer. (sample to be demonstrated). warranty 1 year", "compass aesthesiometer-1. metal body with length 8 – 12 cm2. two arms with adjustable screw to increase or decrease the distance between the two tips from 0 to 7cm.3. sample to be demonstrated.", "detachable ink writing apparatus with ink well for writing on kymograph paper (to be used with marey's tambour for stethography):1. writing ink – blue (4 nos)2. writing to be demonstrated.", digital chemical weighing balance scale ( 0.01gm- 500 gms) with wind shield and spatula. warranty 1 year, digital weighing scale ( measuring max weight of 180 kg), "ecg machine (brand: rms / bpl )1. sing
Tender For supply of lab eqipment : : -cro , signal generator , spin coater unit , digital balance , deioniser , centrifuge , hot air oven , spectrophotometer , muffle furnace , vacuum pump , sonicator , magnetic stirrer with hot plate , polarimeter , ph meter , potentiometer , bunsen burner
Tender For corrigendum : supply of laboratory testing instruments d d - vortex mixture , mixture grinder , refrigerated circulating baths , capillary electrophoresis ce instrument , digital balance up to one , volatile oil determination apparatus , humidity meter , digital thermocouple , digital thermo couple , digital tachometer , hot air oven , milk gerber centrifuge machine for milk , gcms ms cost of equipment man power seven years cmc five years excluding gst eighteen percentage , lcms ms cost of equipment man power seven years cmc five years excluding gst eighteen percentage , icpmsms cost of equipment man power seven years cmc fiveyears excluding gst eighteen percentage , gc fid , nitrogen gas generator , nitrogen gas evaporator , digital butyro refractometer , karl fischer coulometer , turbidity meter , ph meter , micro pippette mechanical , micro pipettte electronic , sulphur dioxide apparatus , temprature controlled waterbath , high processor water bath , bottle top dispensers , weighing balance upto ten kg , high processor water bath chiller , solvent purification system , muffle furnace , magnetic stirrer , melting point apparatus , boiling point , deep freezer , double door refrigerator , hplc with uv detector , ftir , gas liquid chromatograph , polarimeter
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - stirrer- the stirrer should be made up of ceramic coated aluminium alloy top with digital speed and temperature control. the stirring speed should be 50-1500 rpm or better. the stirrer should be operational up to a temperature range of 300oc with an accuracy of 1.0oc and ip 42 protection class. the input power should be 600 w or above. the stirrer should be supplied with hemispheric bowl (100 ml= 1 no; 250 ml= 1 no) to replace oil baths and mantles in order to perform clean and safe analysis with round bottom flasks.warranty must be one year., electronic balance- the electronic balance should have a maximum weighing capacity of 200 g or more with a resolution and repeatability of 0.1 mg, and a response time of 5 sec or better. the system should have automatic internal calibration with touch screen display. the system should have internal database capacity of 2500 or more with multiuser password protection feature. warranty must be one year., vaccum pump - the pump should be operational at a maximum power of 65 w or more with a max. vaccum of 99 mbar or more. the pump should be fitted withvacuum and filter cartridge., hot air oven- the inner chamber should be made of stainlesssteel and the outer chamber should be m.s powdercoated. the maximum capacity of the oven shouldbe 100 ml or more. the operational temperatureshould be between ambient to 250oc or more witha temperature accuracy of 1o c. pid based digitaltemperature control., double distillation unit- the unit should be pyrogen free with a distillation water output capacity of 1.5 l/h. the minimum cooling water requirement should be 1lt/min. auto-power cut facility in case of halted supply of water., circulating oil bath- the oil bath should be made up of stainless steel with 4 digit 7 segment led display for temperature and time. the bath should have s.s perforated tray for holding flasks. the bath should have a capacity to accommodate flask of 1l. the working temperature range should be +5 to 240oc (0.1oc increment) with a temperature stability of 1oc, water bath- the water bath should have a capacity of 20 l within built water level sensor. the bath should be made up of stainless steel and supplied with 8 concentric rings. the bath should have digital temperature control with pt100 sensor. the system should have stirring capability with ptfe magnetic bars., ph/ condutivity meter - operational between a ph range of -2 to 16.00 with a resolution of 0.01 ph and an accuracy of 0.02 ph. 5 points calibration. the ec range shouldbe in between 0.00 to 29.99 s/cm, uv cabinet- operational at two uv wavelengths (254 and 365 nm). the cabinet should also be equipped with one visible light. the external body should be coated with ms powder/epoxy., flame photometer- application: the flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flametemperature. these metals include na+, k+, ca2+, ba2+ and li2+.specification requirementmeasuring range na+: 0 to 99.9 ppm k+:0 to 99.9 ppm ca 2+ :0-99.9 ppmli 2+: 0 to 99.99 ppmsensitivity na+= 0.1 ppmk+ = 0.1 ppmspecificity less than 0.5% interference when concentrations are equal to test sample concentrationsgas control-adjustable with knobsignition system-auto ignition systemflame failure-auto detectiongas cut off-automaticreproducibility-less than 1% coefficient of variation for 20 consecutive samplesusing 10 ppm na set as maximum standardlinearity-less than 1%display led, 12.5 mm (1/2")fuel supply-high-grade propane/butane mixture regulated at approximately30 psiair supply-6 l/min at 12 psi; oil and moisture freerecorder-output 0.05 to 5 v (switchable)operating manuals, service manuals, other manuals should provide user, technical and maintenance manuals in english language list of equipment and procedures required
Tender For supply of pesticide residue analysis laboratory equipments : : -electronic analytical balance , electronic open top loading balance , analytical balance micro , hot air oven for both 130 and 80 litres , table top cooling centrifuge mutlispeed centrifuge for quechers , refrigerated centrifuge , laboratory refrigerator temp range 2 to 8 degree c 3 16 degree c of 1000 l and 360 l capacity , micro pipettes one channel fixed micro pipettes , micro pipettes one channel variable electronic micro pipettes , adjustable volume digital multichannel micro pipettes , soxhlet extraction assembly fully automatic , solid phase extraction manifold , laboratory grinder , horizontal deep freezer of 300 500 litres , bath sonicator , vortex mixer shaker , digital ph meter , magnetic stirrer with hot plate , rotatory evaporator with recirculating chiller , microwave digestion system , shakers homogenizer incubator high volume , shakers homogenizer incubator low volume