Web Analytics Made Easy - StatCounter

Stone Signage Tenders

Get complete information related to latest Stone Signage Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Stone Signage Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Stone Signage Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :41037856 Due date: 22 Jul, 202522 Jul, 2025 7.68 Crore
Tender For mgsy/25-26/jhajha/01 - construction of rcc hl bridge on kiyajori se maharaidih, foundation, earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.i) upto 3m depth, providing and laying of pcc m15 levelling course 100mm thick below the pile cap.ii. pcc grade m-15 (levelling course for pile cap), r.c.c. grade m 30 in pile foundation complete as per dwg & tech specification.pile cap in rcc m-30, bored cast-in-situ m35 grade r.c.c. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m.ii. 1200 mm dia, supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawings and technical specifications clauses 1000 and 1202, providing steel liner 10 mm thick for curbs and 6mm thick for steining of wells including fabricating and setting out as per detailed drawing, providing and constructing temporary earth island (assuming depth of water 1.0 m and height of island to be 1.25 m including royality for earth @ rs. 5526.00 for each island.), providing and constructing one span service road to reach island location from one pier location to another pier location including royality for earth @ rs. 225.00 per m for service road., carrying out load test on any pile as per standard procedure laid down in the is:2911 specification including construction of test cap, dismantling the cap after test and cleaning the site and maintaining complete records of load1.2 m dia pile, b) routine pile load test on pile for 1.5 times the design load specified in drawings1.2 m dia pile (2% of piles in total)., c) horizontal pile load test on pile for 1.5 times the design load specified in drawings1.2 m dia pile (2% of piles in total) ., substructure, r.c.c. grade m-30 in substructure complete as per dwg & tech specificationi) upto 5m height (using concrete mixer), ii) from 5m upto 10m height (using concrete mixer), r.c.c. grade m-35 in substructure complete as per dwg & tech specificationii) from 5m upto 10m height (using concrete mixer), supplying, fitting and placing hysd bar reinforcement (fe 415) in substructrue complete as per drawings and technical specification clauses 1002, 1005, 1010 & 1202, supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia ac pipe extending through the full width of the structures with slope of 1(v):20(h) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7, backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification clause 1204.3.8 i) sandy material, providing and laying filter media with granular crushed aggregates (jhama metal) as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification clause 1204.3.8, superstructure, providing and laying reinforced cement concrete in superstructure complete as per drawing and technical specifications clauses 800, 1205.4 and 1205.5ii. rcc m-30, supplying, fitting and placing hysd bar reinforcement (fe 415) in superstructrue complete as per drawings and technical specification clauses 1002, 1010 & 1202, providing and laying cement con

CTN :41037837 Due date: 22 Jul, 202522 Jul, 2025 15.13 Crore
Tender For mgsy/25-26/bhabhua/01 - name of work: construction of proposed hl rcc bridge on durgawati river at swar gadh of rampur block in the dist-kaimur(bhabhua), length- 111.60mfoundationexcavation for structuresearthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.i) upto 3m depth, providing and laying of pcc m15 levelling course 100mm thick below the pile cap.ii. pcc grade m-15 (levelling course for pile cap), r.c.c. grade m 35 in pile foundation complete as per dwg & tech specification.pile cap in rcc m-35 (using batching plant, transit mixer and concrete pump), bored cast-in-situ m35 grade r.c.c. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m.ii. 1200 mm dia (using batching plant, transit mixer and concrete pump), supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawings and technical specifications clauses 1000 and 1202, providing steel liner 10 mm thick for curbs and 6mm thick for steining of wells including fabricating and setting out as per detailed drawing, providing and constructing temporary earth island (assuming depth of water 1.0 m and height of island to be 1.25 m including royality for earth @ rs. 5526.00 for each island.), carrying out load test on any pile as per standard procedure laid down in the is:2911 specification including construction of test cap, dismantling the cap after test and cleaning the site and maintaining complete records of loada) initial load test on test pile for 2.5 times the design load specified in drawings1.2 m dia pile, b) routine pile load test on pile for 1.5 times the design load specified in drawings1.2 m dia pile (2% of piles in total)., c) horizontal pile load test on pile for 1.5 times the design load specified in drawings1.2 m dia pile (2% of piles in total) ., substructurer.c.c. grade m-30 in substructure complete as per dwg & tech specificationrcc m-30 (using batching plant, transit mixer and concrete pump)i) upto 5m height (using batching plant, transit mixer and concrete pump), ii) from 5m upto 10m height (using batching plant, transit mixer and concrete pump), supplying, fitting and placing hysd bar reinforcement (fe 415) in substructrue complete as per drawings and technical specification clauses 1002, 1005, 1010 & 1202, supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia ac pipe extending through the full width of the structures with slope of 1(v):20(h) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7, backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification clause 1204.3.8 i) sandy material, providing and laying filter media with granular crushed aggregates (jhama metal) as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification clause 1204.3.8, superstructureproviding and laying reinforced cement concrete in superstructure complete as per drawing and technical specifications clauses 800, 1205.4 and 1205.5ii. rcc m-30 (using batching plant, transit mixer and concrete pump), supplying, fitting and p

CTN :41037847 Due date: 22 Jul, 202522 Jul, 2025 12.35 Crore
Tender For mgsy/25-26/begusarai/01 - construction of h.l rcc bridge ( 6 x 21.750 m) in between mathar kasimpur kurmi tola road and gupta lakhminiya rcd road under matihani block in the district of begusarai ., excavation for structures , earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. up to 3.00 m depth ., providing and laying cutting edge of mild steel weighing 40 kg per metre for well foundation complete as per drawing and technical specification. as per morth clause no. - 1200&, plain cement concrete in open foundation complete as per drawing and technical specifications pcc grade m -15 below abutment well cap, providing cement concrete /reinforced cement concrete with batching plant, transit mixer and concrete pump as per drawing and technical specification rcc m-35 in well curb, providing plain cement concrete with batching plant, transit mixer and concrete pump as per drawing and technical specification , pcc m-25 in well bottom plug, providing cement concrete /reinforced cement concrete with batching plant, transit mixer and concrete pump as per drawing and technical specification , rcc m-25 in well steining, providing plain cement concrete with batching plant, transit mixer and concrete pump as per drawing and technical specification , pcc m-25 in well intermediate plug, well sinking as per technical specification, depth 0.00m to 3.00 m (clay soil), depth 3.00m to 10.00 m (sandy soil), depth 10.00m to 20.00 m (sandy soil), depth 20.00m to 30.00 m (sandy soil), for 7.00 m dia well :; pier, depth 0.00m to 3.00 m (clay soil), depth 3.00m to 10.00 m (sandy soil), depth 10.00m to 20.00 m (sandy soil), depth 20.00m to 30.00 m (sandy soil), sand filling in wells complete as per drawing and technical specifiction. as per morth clause no. - 1207, providing cement concrete /reinforced cement concrete with batching plant, transit mixer and concrete pump as per drawing and technical specification , rccm-35 in well cap, providing and constructing one span service road to reach island location from one pier location to another pier location including royality for earth @ rs. 225.00 per m for service road., providing and constructing temporary island 16 m diameter for construction of well foundation for 8m dia. well in one water, supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawing and technical specifications , tmt in foundation , refer bbs ,qty = 67.622+155.612 =223.234 t, confirmatory boring at abutment and pier location, back filling behind abutment, wing wall and return wall complete as per drawing and technical specification, providing and laying of filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of morth specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification., plain/reinforced cement concrete in sub-structure complete as per drawing and technical specificationsheight upto 5m , rcc grade m30, plain/reinforced cement concrete in sub-structure complete as per drawing and technical specifications ,rcc grade m30 , height 5m to 10m, supplying, fitting and placing hysd bar reinforcement in sub-structure complete as per drawing and technical , reinf , qty = 23.851+24.330+1.762+0.313+1.289+1.139 =, providing weep holes in brick masonry/plain/ reinforced concrete abutment, wing wall/ return wall with 100 mm dia ac pipe, extending through the full width of the structure with slope of 1v :20h towards drawing foce. co

CTN :41037854 Due date: 22 Jul, 202522 Jul, 2025 9.00 Crore
Tender For mgsy/25-26/teghra/01 - construction of h.l rcc bridge ( 6 x 21.750 m) in alapur to pasopur & l021 to pakthaul , ( khijir chak abm kirtoul ke bich balan nadi par pul ) under teghra block in the district of begusarai, excavation for structures , earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. up to 3.00 m depth ., levelling course for pile cap , providing and laying of pcc m15 levelling course 100mm thick below the pile cap., providing and laying reinforced cement concrete as per drawing and technical specifications clauses 800, 1205.4 and 1205.5 , rcc grade m -35 in pile cap, bored cast in situ piles r.c.c m-35 , pile excluding reinforcement complete as per drawing and technical specification and removal of excavated earth with all lift and lead up to 1200 m, supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawing and technical specifications , tmt in foundation , refer bbs ,qty = 54.273+16.411+74.929+ 29.651= 175.264, 6mm thick. steel liner as per drawing and technical specification ., providing and constructing temporary island 16 m diameter for construction of well foundation for 8m dia. well. assuming depth of water 1.0 m and height of island to be 1.25 m including royality for earth @ rs. 3768.00 for each island., pile load test on single vertical pile in accordance with is:2911(part-iv) 1985, a) initial load test @ 2.5 times load on 1 pile, b) routine load test @ 1.5 times load on 2% pile, c) lateral load test, confirmatory boring at abutment and pier location, back filling behind abutment, wing wall and return wall complete as per drawing and technical specification, providing and laying of filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of morth specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification., plain/reinforced cement concrete in sub-structure complete as per drawing and technical specificationsheight upto 5m , rcc grade m30, plain/reinforced cement concrete in sub-structure complete as per drawing and technical specifications ,rcc grade m30 , height 5m to 10m, supplying, fitting and placing hysd bar reinforcement in sub-structure complete as per drawing and technical , reinf qty = 20.810+28.454+1.762+0.313+1.289+1.139 =53.77, providing weep holes in brick masonry/plain/ reinforced concrete abutment, wing wall/ return wall with 100 mm dia ac pipe, extending through the full width of the structure with slope of 1v :20h towards drawing foce. complete as per drawing and technical specifications, supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., furnishing and placing reinforced/prestressed cement concrete in super-structure as per drawing and technical specificatio,rcc grade m 30, height 5m to 10m, reinforeced cement concrete m30 grade approach slab including reinforcement and formwork complete as per drawing and technical specification, pcc m15 grade leveling course below approach slab complete as per drawing and technical specification, construction of rcc railing of m30 grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical rcc post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space b

CTN :41037844 Due date: 22 Jul, 202522 Jul, 2025 13.03 Crore
Tender For mgsy/25-26/balia/01 - construction of h.l rcc bridge ( 8 x 21.750 m) in between t01 se sonwarsha path under shamho akha kurha block in the district of begusarai, excavation for structures , earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. up to 3.00 m depth ., providing and laying cutting edge of mild steel weighing 40 kg per metre for well foundation complete as per drawing and technical specification. as per morth clause no. - 1200&, plain cement concrete in open foundation complete as per drawing and technical specifications pcc grade m -15 below abutment well cap, providing cement concrete /reinforced cement concrete with batching plant, transit mixer and concrete pump as per drawing and technical specification rcc m-35 in well curb, providing plain cement concrete with batching plant, transit mixer and concrete pump as per drawing and technical specification , pcc m-25 in well bottom plug, providing cement concrete /reinforced cement concrete with batching plant, transit mixer and concrete pump as per drawing and technical specification , rcc m-25 in well steining, providing plain cement concrete with batching plant, transit mixer and concrete pump as per drawing and technical specification , pcc m-25 in well intermediate plug, well sinking as per technical specification, depth 0.00m to 3.00 m (clay soil), depth 3.00m to 10.00 m (sandy soil), depth 10.00m to 20.00 m (sandy soil), depth 20.00m to 30.00 m (sandy soil), for 7.00 m dia well :; pier, depth 0.00m to 3.00 m (clay soil), depth 3.00m to 10.00 m (sandy soil), depth 10.00m to 20.00 m (sandy soil), depth 20.00m to 30.00 m (sandy soil), sand filling in wells complete as per drawing and technical specifiction. as per morth clause no. - 1207, providing cement concrete /reinforced cement concrete with batching plant, transit mixer and concrete pump as per drawing and technical specification , rccm-35 in well cap, supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawing and technical specifications , tmt in foundation , refer bbs ,qty = 67.622+155.612 =223.234 t, confirmatory boring at abutment and pier location, back filling behind abutment, wing wall and return wall complete as per drawing and technical specification, providing and laying of filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of morth specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification., plain/reinforced cement concrete in sub-structure complete as per drawing and technical specificationsheight upto 5m , rcc grade m30, plain/reinforced cement concrete in sub-structure complete as per drawing and technical specifications ,rcc grade m30 , height 5m to 10m, supplying, fitting and placing hysd bar reinforcement in sub-structure complete as per drawing and technical , reinf , qty = 23.851+24.330+1.762+0.313+1.289+1.139 =, providing weep holes in brick masonry/plain/ reinforced concrete abutment, wing wall/ return wall with 100 mm dia ac pipe, extending through the full width of the structure with slope of 1v :20h towards drawing foce. complete as per drawing and technical specifications, supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., furnishing and placing reinforced/prestressed ceme

CTN :40939131 Due date: 21 Jul, 202521 Jul, 2025 NA
Tender For supply of ordinary portland cement grade 43,sand fine,stone aggregates graded 10-20mm,stone aggregates graded 20-40mm,stone aggregates graded 40-63mm,chloride free accelerating admixture,400 micro polyethine film sheet,water reducing admixture,primer for ceiling compound,polyethelene ceiling compound,wet hasseing cloth for curing high range,acrylic based pavement road marking paint

CTN :41025898 Due date: 24 Jul, 202524 Jul, 2025 NA
Tender For supply of 8 x security light solar - solar module 80wp 40w panel , 6mtr long 80mm dia hot dip galvanised med grade pipe , 6 sqmm twincore 1100 volt hvy dty , 1 sqmm cable copper , insulated tape , ordinary cement portland , coarse sand , 20mm stone aggregates , 32 amp main switch , 32 amp change over switch

CTN :40404659 Due date: 17 Jul, 202517 Jul, 2025 NA
Tender For bid to ras supply of aggregate - m sand confirming to is 383-2016 specification for coarse and fine aggregates free fromadherent as per tech att , aggregate 20mm stone aggregate to be crushed rock or gravel 20mm graded confirming to relevant is and as per tech spec , aggregate 40mm stone aggregate to be crushed rock or gravel 40mm graded confirming to relevant is and as per tech spec , ms binding wire 0.9mm as per tech spec , rapidite quick setting liquid as per tech spec

corporations/Associations/Others

CTN :41052702 Due date: 05 Aug, 202505 Aug, 2025 50.00 Lacs
Tender For annual maintenance work for pwd branch with material & labours work year 2025-26 - box cutting the road surface to proper slope and camber for making a base for road work including removing the excavated stuff and depositing on the road side slope as directed upto 50 m., demolition of brick work and stone masonry including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.ii in cement mortar., dismentaling tiled of stone floors laid in mortar including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift., demolition including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift. i r.c.c. work, excavation for foundation up to 1.5 meter depth including sorting out and stacking of useful materials and disposing of excavated stuff up to 50 meter lead a for loose or soft soil, filling available excavated earth excluding rock in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each deposited layer by ramming and watering, filling in foundation and plinth with murrum or selected soil in layers of 20 cm thickness including watering, ramming and consolidating etc. complete., providing and laying compacted w.b.m. 100 mm. thick of grading i b.t. metal of size 45 mm to 90 mm in two layers including using 22 percentage stone screening 13.2 mm size and 7 percentage stone dust as filler including spreading, watering and consolidation by vibratory roller etc. complete., providing and laying compacted w.b.m. 150 mm. thick of grading ii b.t. metal of size 45 mm to 63 mm in two layers including using 13 percentage stone screening 13.2 mm size and 7 percentage stone dust as filler including spreading, watering and consolidation by vibratory roller etc. complete., providing and laying cement concrete 1gem3gem6 1 cement gem 3- coarse sand gem6- hand broken stone aggregate 40 mm. nominal size and curing complete excluding cost of form work in gema foundation and plinth, providing and casting in situ controlled cement concrete m-200 for average 100 mm thick wearing coat laid as directed dincluding tamping, vibrating, finishing, curing and fillingin joints with bitumen complete, providing and laying cement concrete 1gem3gem6 1- cement gem 3- coarse sand gem 6- crushed stone aggregates 20 mm nominal size and curing complete including cost of formwork in a wall caps per coping, providing laying controlled cement concrete m-200 and curing complete including the cost of form work and excluding cost of reinforcement for reinforced concrete work in gem rcc lintels, providing laying controlled cement concrete m-250 and curing complete including the cost of form work and excluding cost of reinforcement for reinforced concrete work in gem rcc slabs and landings, providing and casting in situ ordinary cement concrete m-200 forkerbsperkerb blocks including formwork, curing and finishing complete., providing tmt bar fe 415 reinforcement for r.c.c. work including bending, binding and placing in position complete upto floor two level, white stone bela masonry block in course in foundation, plinth and super structure with stone of approved quality in cement mortar 1gem5 1cement gem 5 course sand including racking the joints etc. complete., white stone bela masonry work in partition walls up to 15 cm thickness in cement mortar 1 gem 4 course sand, providing 10 mm thick cement plaster in single coat on ceiling and soffit of stair for interior plastering up to floor two level and finished even and smooth including finishing with a floating coat of neat cement slurry for plastering on ceiling and soffits of stairs up to floor two level instead of plastering on walls. ii cement mortar 1gem4 1 cement gem 4 sand, providing 15 mm thick cement plaster in single coat on fair side brickperconcrete walls for interior plastering up to floor two level and finished even and smooth including fini

CTN :40402680 Due date: 14 Jul, 202514 Jul, 2025 NA
Tender For bid to ras supply of sand and crused stone - m sand confirming to is 383-2016 specification for coarse and fine aggregates free fromadherent as per tech att , aggregate 20mm stone aggregate to be crushed rock or gravel 20mm graded confirming to relevant is and as per tech spec , aggregate 40mm stone aggregate to be crushed rock or gravel 40mm graded confirming to relevant is and as per tech spec , ms binding wire 0.9mm as per tech spec , rapidite quick setting liquid as per tech spec
 Loading, Please wait...

Connect us via What's Up