Tender For corrigendum : - tender for aug. of existing 250kva, 11/0.4 kv s/stn. jibhi into 400kva, 11/0.4 kv s/stn. in (e ) section jibhi uesd, hpsebl, banjar. (t.s. 09/2025-26) - supply part dtr 400 kva, supply of lt distribution panel box suitable for 400 kva s/stn of size 1100x800x275mm +/- 5% made of steel sheet of 1.63 mm thickness having double door locking arrangement duly powder coated painted complete withlt distribution panel box with mccb 630 amp 3p 50ka-1 no. make l&t , schneider and abb only, mccb 250 amp 36ka 3p of l&t schneider and abb make only 3no. mccb rating 250amp, 3 poles having following specifications (1) minimum frame size 250 amp (2) type variable trip free, (3) breaking capacity- isu & lcs at 415, 50 hz (ka: not less than 50 ka) (4) , thermal release range: 320-440amp (5) mecanical life (operation) 20000 no. (6) electrical life (operation) 4000 no. (7) rated insulation voltage (v) 690v (8) tripping thermal releasing setting : thermal-o/l variable setting (9) tripping magnetic releasing setting : magnetic- s/c fixed setting (12) in (10) (operation) volatge 415v, ac (11) caliberation temperature: 40 degree c (12) high voltage withstand voltage : 3kv for 1 minute (13) confirming to is : 1993/60947-2, 1989 (14) make l&t/ havells/abb/ hpl/ schiender and approved vendor of hpsebl (15) ics : 100% icu reangular type aluminum alloy bus bar of 250 amp. having length 800 mm of phase 800 mm long for netural outgoing feeder 3 nos. outgoing feeders shall be made in the pannel u type single pole mccbs of 400 amp. shall be provided in all 3- phases. the panel shall be fully wired with insulated copper wire have adequate clearance . as per standard specification, supply of aluminium thimble, supply of aluminium thimble, supply of lt cable (3.5 core ) 400 mm2 (incomer), supply of lt cable (3.5 core ) 240 mm 2 (outgoing), erection of dtr, erection of 400 kva , 11/0.433kv dtr, erection of lt box, providing earthing connection including g.i.wire to g.o switch erection of jumper, laying of lt cable, complete in all respect., transportation charges inclusive of hydra crane charges and mannual carriage of dtr and its associate material., add dismantling charges of old dtr (250 kva dtr) and allied accessories @50% of erection of new dtr.
Tender For tender for supply of procurement of spare of lt vfd at hurl sindri on oem basis : : - dual temperature transmitter, filter capacitor for sine wave fitter, "current transformer ratio 100/1avfd control devicevfd power devicehrc fuse link bs typefuse holders & isolating linkhrc fuse 8s typefuse-link rating-80a, ac 690 v.", fuse base nh din type, output filter ral 7035 size 6 inc, fan failure and temp detection unit, top (intelligent operator panel), "power contactor rating-45a, 230v acsine wave fitter reactor rating-22kw", panel fan, multi-function meter (mfm), 32-50 a, thermal overload relay, circuit breaker with electronic trip, panel door mounted rotary op, handles, d series dc drm relay, d series drm relay socket, 4 contacts, d series ac drm relay, sa, d series ac dirm relay, 10a, d series drm relay socket, 2 contacts, digital indicator (rpm meter), transformer, 415vac/240vac, 500va, auto transformer, 22kva 3 pole, current transducer specs 4-20ma, motor restart timer, green push button & contact block., red push button & contact block, selector switch, 2-way, selector switch, 3-way, blue push button & contact block, yellow push button & contact block, black push button & contact block, fuse terminal, thermostate, high current connectors, 40mm insulator, 30mm insulator, indicating lamp, red, indicating lamp, yellow, indicating lamp, blue, indicating lamp, green, indicating lamp, amber
Tender For providing additional 02 nos of 11kv, mei make, 350mva, 20ka, out door type 800a feeder panel and annunciator panel (2f,1ap for feeder) scada compatible pcvcb required at 66/11kv bukkapatna s/s coming under sira nodal, madhugiri operation division. including supply of equipments/materials, erection (including civil works), under partial turnkey basis
Tender For providing additional 1 no of 11kv, mei make, 350mva, 20ka, out door type 800a feeder panel and annunciator panel (1f 1ap for feeder) scada compatible pcvcb required at 66/11kv brahmasandra s/s coming under sira nodal, madhugiri operation division. including supply of equipments/materials, erection (including civil works), under partial turnkey basis.
Tender For providing additional 1 no of 11kv, mei make, 350mva, 20ka, out door type 800a feeder panel and annunciator panel (1f 1ap for feeder) scada compatible pcvcb required at 66/11kv chikkabanagere s/s coming under sira nodal, madhugiri operation division. including supply of equipments/materials, erection (including civil works) under partial turnkey basis
Tender For carriage of light melting scrap(lms) items consisting of wagon body(in dismantled/cut conditions), wagon cbc components without rubber(for example couplers and draft gears without pads), wagon bogies(in dismantled condition), wagon end buffers, yoke, knuckles, springs(including springs used in casnub bogies), ms angles, tie bars, ms panel sheet & wagon door, ms sheet, scrap ms melting, ms adopter wide jaw and narrow jaw, ms cub spacer, ms shearing plate, bogie frame bolster, ms plate, ms ingot and others; from various railway units in india to rail wheel factory, yelahanka, bengaluru-560064; distance:0-500kms (with a minimum chargeable distance of 100kms), by road.special note: the consignor railway authorities shall ensure that cast iron and/or sulphur embedded items are not offered for loading.note: the work involves other intermediary and ancillary activities such as:(a)collection of lms (b)loading the lms into the vehicle. the contractor shall load only those lms items which are free from rubber components or any other attachments(c)unloading at destination, by railways at free of cost.quantity: 5500 mt. special note: (1) tenderers should quote the rates based on the diesel price of rs.90.99 per litre prevailing at bengaluru as on estimation date i.e., 03.10.2025 and the same shall be considered for the purpose of evaluation. (2)mandatory documents should be submitted in compliance of: bid security conditions including annexure vi(a), annexure-v, annexure-v(a), annexure-vi(b), power of attorney and iba certification. (3) non-submission of necessary documents in support of the above may result in rejection of bids.
Tender For bid to ras procurement of rodent thermostable container - ms pipe 40 into 40 into 3 mm , ms pipe 76 into 80 into 3 mm , puf panel 8 feet into 3 feet , puf panel 6 feet into 3 feet for roof , steel door with frame , nut and bolts , checker palete 3 mm size 8 into 4 , labour charges for fixing and installation