Get complete information related to latest Straw Board Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Straw Board Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Straw Board Tenders.
Tender For supply of feeders-1&2 and bus coupler, power contactors, 3pole, 1000v ac, 50hz, suitable for 500 kva, 750v ac onload switching under ac-6a category at temperature of 70 degree c &coil voltage of 110v dc +25%-30% with surge suppressor, 2no+2nc, as per rdso spec no. rdso/pe/spec/d/tl/0195-2019 (rev.-0) suitable for switch board cabinet for hog compliant lslrd coaches. accepted makes & models as per s.no.1 of bom of rdso specification mentioned in the above description : (i) abb af1250, (ii)l&t mvo 820, (iii) 3rt12766nf368ka0 of siemens (vide jdse (tl-ac systemdesign) / rdso lr. no. el/7.1.108/sbc/lslrd dt.08.11.23 attached for this modified model number) only. [ warranty period: 30 months after the date of delivery ]
Tender For supplying and fixing of electrical fitments for newly constructed toilet of d coy barrack and new jamin toilet at stc bsf of north bengal electrical installation - wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc as required. group b, rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm. frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. group b, wiring for circuit/ submain wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire., wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required.2 x 4 sq. mm + 1 x 4 sq. mm earth wire. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire., supplying and fixing 3 pin 5 amps ceiling rose on the existing junction box/ wooden block including connection etc. as required. 3 pin 5 amp, supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. size : 180mm x 100mm x 60mm deep., supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator). 8 way , double door., supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, "c"curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole., supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, "c"curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.single pole and neutralsingle pole and neutral., earthing with g.i. earth pipe of following size including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 4.5 metre long, 40 mm dia ., supplying and laying following size g.i. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with gi thimble etc. as required.6 swg., supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted /welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. standard make., add applicable rate of gst @18% in place of 12% (0.0633mf) on dsr item. s no.(1 to 12), add 1% labour cess on s no. (1 to 12) + s no.13, modified estimate cost after using correction factor on account of gst @ 0.973 on dsr items s no. (1 to 12) + s no.13 + s no.14, supplying and fixing 3 mm thick phenolic laminated sheet cover in front of ms switch box including making hole and al. alloy/ cadmium plated iron screws, 20 mm, washers etc. as required.hylem/formica/anchor/as approved by engg incharge., supplying and fixing of 6 watt surface type trim cosmo panel square shape led light suitable for 240 volt, single phase, 50
Tender For supply and replacement of internal and external electrical installation at conference room, badminton room and other location in siri fort sports complex. - wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the pointwith 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. (i/c rebate of replaced item).a) group c (dsr-2022,1.10.3), wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed pvc conduit, and earthing the point with 1.5 sq. mm f copper conductor single core cable etc. as required. (i/c rebate of replaced items)a) group c (dsr2022, 1.55.3), wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed meduim class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing (i/c rebate of replaced items) as required. (dsr-2022,1.12), wiring for light/ power plug with 4x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 2 nos. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. (i/c rebate of replaced items)(dsr-2022,1.13), wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, singlecore cable in surface/ recessed medium class pvc conduit as required. (i/c rebate of replaced items)a) 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire (dsr-2022,1.14.1), b) 4 x 16 sq. mm + 2 x 6 sq. mm earth wire (dsr-2022,1.14.11), supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephonecable in the existing surface/ recessed steel/ pvc conduit as required. (i/c rebate of replaced item). 1 pair (dsr-2022,1.18), supplying and fixing following size. modules. gi box along with modular base cover plate for modualr switches in recess etc. as reqd.(i/c rebate of replaced items) (a) 1 or 2 module (75mm x 75mm) (dsr-2022,1.27), supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (i/c rebate of replaced items)a) telephone socket outlet (dsr-2022,1.24.6), supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (i/c rebate ofreplaced items) (dsr-2022,1.25), supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing andfixing 3 pin 5/6 a modular socket outlet and 5/6 a modular switch, connections etc. as required. (i/c rebate of replaced items) (dsr2022,1.31), supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required. (i/c rebate of replaceditems) (dsr-2022,1.32), supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) (i/c rebate of replaced items) (dsr_2022)a) 4 way (4 + 12), double door, b) 6 way (4 + 18), double door, c) 8 way (4 + 24), double door, supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, "c" curve, miniature circuit breaker suitable for inductive load of following poles in the ex
Tender For purchase of electrical and mechanical spares computer (control pc for afx2), part no. l0041056 , ups (afx usv, af1-1105g1), part no. l0041061/l0041088 , accumulator (afx usv, af1-1105g2), part no. l0041061/l0041089 , positioning module, type:l0048460 , circuit board (af1-1109u1), part no. l0048787 , circuit board (af1-111001 and 1111u1), part no. l0048788 , circuit board, afx, l0048790 , diode (h-95v1 and h-95v2), part no. l0052698 , power pack, 1l-834g3, part no. l0053048 , optocoupler, part no. l0054335 , frequency converter (acs380), part no. l0068735 , power pack, qt20.241, l0070178 , initiator (n-937b3 n-937b4), part no. l0070521 , input module part no. l0070657 , bus module, part no. l0070681 , mw computer, part no. l0070742 , time lag relay (af1-1133k1), part no. l0070826 , time lag relay (af1-1133k1), (monitoring relay), part no. l0070826 , overload cut-out, part no. l0071275 , overload cut-out, part no. l00712 , main switch (af1-112151), part no. l0041451 , power pack (pulse qt40.241), part no. l072236 , input/output module (plc), part no.l0072280 , module carrier (plc), part no. l0072290 , central processor unit (plc r-281a1-d1), part no. l007231 , adjusting drive (posmo-motor), part no. l0072514 , position control module (-436n1), part no. l0072857 , position control module (-436d1), part no. l0072881 , contactor (e-21k5), part no. l0072523 , power pack (h-93g1), part no. l0073289 , relay (-433k1), part no. l0073553 , control instrument (-463n1), part no. l0073531 , brake lining susi (l6547310) , roller chain susi (l6547321) , guide bush susi (l6938240) , torsion bar spring asbly susi (l7009350) , torsion bar spring asbly susi (l7009350) , ring susi(l7035900) , gripper pad susi(l7099900) , suction tape susi (m8256370) , brush roller susi(m8401684) , brush roller susi(m8402350) , disk susi(m8431010) , disk susi(m8431020) , disk susi(m8431030) , disk susi(m8431040) , nozzle susi (m8431050) , disk susi(m8431150) , disk susi(m8431160) , sucker susi(m8436961) , sucker susi(m8437071) , stripper susi (m8437634) , pressure spring susi(m8438040) , stripper spring susi(m8438410) , stripper spring susi(m8438411) , tension spring susi (p0009510) , gripper susi(p0734050)
Tender For corrigendum : repairs of community toilet at ward no 10 near danappa house and ward no 4 harijanakeri welcome board and old bus stand community toilet in tmc kampli
Tender For bid to ras supply of diesel for running of school bus for 10 months , engine oil 10w 30v , complete seat side panelling upto window , full body paint original in metallic 2k , complete seat cover with foam , window curtains , head and fog lights , brake lights , indicators front and rear and sides , new wiper machine with wipers , dash board meter , trupal budy cover 30 ft by 40 ft , tyre well cup , fire extinguisher 10ltrs type abc , floor wooden waterproof ply 19mm , labour charges for wiring of full bus
Tender For supply of supply of sitc of spd and conventional earthing system at lilabari airport d d - surge protection device as per rquirements , supply copper plate as per rquirements , supply of copper strip as per rquirements , supply of copper bus bar with 6 holes , supply of salt , supply of charcoal , supply of galvanized iron gi pipe , concrete cementing chamber , concrete cementing chambers metallic cover , supply of hdpe pipe , supply of funnel , supply of pvc insulated insulated copper wire , construction of earthing system earth pit , supply of earthing sign board , installation testing and commissioning of above alongwith items as described in item description
Tender For supply of provision of lighting arrangement for the watch tower along with solar system at kushinagar airport : : - design and sitc of off grid solar system of 1 kwp capacity along with suitable capacity inverter and 2 nos. of 150 ah solar tubular battery along with necessary module mounting structure & civil works like foundation etc. as required at site for upssf watch tower in operational area of airport., supply of 4c x 6 sq. mm xlpe insulated & pvc sheathed, armored aluminium conductor cable of 1.1kv grade as per is 7098 (part i) 1988 with up to date amendments etc. complete as required., laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required.upto 35 sq. mm (clamped with 1mm thick saddle), laying of hdpe pipe upto size 50 mm complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required., laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/hume/metal pipe as required.upto 35 sq. mm, supplying and fixing of following way single pole and neutral, sheet steel, mcb distribution board 240 v, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 6 way, double door, supplying and fixing 6 amps to 32 amps rating, single pole, 240 volts, 10 ka, c curve, miniature circuit breaker suitable for inductive loads in the existing mcb db complete with connections, testing and commissioning etc. as required., supplying and fixing dp mcb 32 amps, double pole, rating, 240 volts, 10 ka, c curve, miniature circuit breaker in the existing mcb db complete with connections, testing and commissioning etc. as required., wiring for light point/fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit, with modulat switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper stranded conductor single core cable etc. as required.(group c), wiring for circuit/ sub-main wiring along with earth wire with 2x2.5 sq.mm+ 1x 2.5 sq.mm earth wire.sizes of frls pvc insulated copper conductor, single core stranded cable in surface/ recessed steel conduit as required., supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required., supply of 20 watt led batten surface mounted suitable for operation on 230 volt,50hz ac supply, complete etc as required., supply of 400 mm, 2100 rpm wall mounting swinging fan suitable for single phase 230 volt, 50 hz ac supply complete with motor, capacitor, mounting clamps etc. with all accessories as required complete., installation, testing and commissioning of pre-wired led fitting luminaries etc. of all types (surface/recessed) & street lights complete with all accessories. directly on ceiling/ wall , including connection with 1.5 sq.mm frls pvc insulated, stranded, copper conductor single core cable with flexible conduits and coupler and earthing etc. as required., installation of wall mount fan in the existing opening including making good the damage, connections, testing and commissioning etc. as required.upto 450mm sweep., supply of led street light of minimum lumen output of 3600 lumen made up of pressure die cast aluminum housing with membrane filter and have ip66 optical as well as electrical compartment with wide operating voltage range of 230+/- 10 percentage complete with all accessories as required., providing & fixing 32/40 mm dia b class gi