Web Analytics Made Easy - StatCounter

Support Braces Tenders

Get complete information related to latest Support Braces Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Support Braces Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Support Braces Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :40997909 Due date: 29 Jul, 202529 Jul, 2025 29.00 Lacs
Tender For special repairs replacement to e/m equipments and infrastructure at af stn jamnagar under ge (af) jamnagar no 1 - supply, installation and testing air cooled inverter based split ac unit with cooling functions and suitable to operate at ambient conditions of (22 deg c + 3 in cooling mode) air conditoner will have following conditons :- (a) refrigerant - r-410 a/r-32 (b) eer- 5 star rating (c) tonnage - 1.5 tr (d) indoor noise level - not more than 40 db (e) filter - as recommended by oem (f) remote - as recommended by oem including 02 nos remote bty (g) temp display, turbo mode and auto swing facility all specification will be as per is-1391 (part 2) and latest amendments as specified as directed by engineer-in-charge., supply, installation and testing air cooled inverter based split ac unit with cooling functions and suitable to operate at ambient conditions of (22 deg c + 3 in cooling mode) air conditoner will have following conditons :- (a) refrigerant - r-410a/r-32 (b) eer- 5 star rating (c) tonnage - 2 tr (d) indoor noise level - not more than 40 db (e) filter - as recommended by oem (f) remote - as recommended by oem including 02 nos remote bty (g) temp display, turbo mode and auto swing facility all specification will be as per is-1391 (part 2) and latest amendments as specified as directed by engineer-in-charge., note for item no 1 & 2 :- the cost of following items deemded to be included in quoted rate.(a) copper pipe duly insulated between indoor/outdoor unit upto lenght 10mtr for each unit (b) ms bracket for outdoor unit duly power coated with fixing arrangement.(c) making of hole in walls including civil work , sleeves and making good to the disturbed surface/wall.(d) testing and commissioning of the air conditioner to the entire satisfaction of engineer in charge(e) pvc round sheathed copper cable of suitable size for connecting indoor and outdoor unit upto supply point as per site requirement (f) taking down of existing ac and deposited to e/m store yard without any damage., supply and installation of voltage stabilzer for automatic operation single phase naturally air cooled indoor type and designed for input varioution between 180v to 250v without voltage stabilzed at 230v with accuracy of (+) 2.5% and capacity 4 kva as specified as directed by engineer-in-charge., supply and installed voltage stabilzer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 180v to 250v without voltage stabilzed at 230v with accuracy of (+) 2.5% and capacity 5 kva as specified as directed by engineer-in-charge., material & labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4.0 sqmm each, pvc insulated, unsheathed, fire retardant, low smoke (frls) drawn through and including pvc casing capping with all necessary fitting and including one run of single core multistranded copper conductor cable, of size 4.00 sqmm, pvc insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified and as directed by engr-in-charge.note: 2 runs of main copper conductor, one run earth wire and pvc casing capping will be measured as one running meter for payment., s&f sheet metal enclosure , 20a single pole and neutral with a two pin and earth plug and socket complete in metal clad board (industrial type) with one single pole mcb 32 amp fixed properly on in concealed position all as specified as directed by engineer-in-charge., supply, installation, commissioning and testing in replacement of loop card having 254 devices of both detectors and modules in a single line circuit, slc supports both class a and class b wiring complete as specified and as directed by engineer-in-charge. make: ravel/honeywell/ceasefire industries pvt ltd, supply, installation, commissioning and testing in replacement of addressable smoke detector with base with binary coded address setting. dual leds for 360 visibil

CTN :40900062 Due date: 02 Sep, 202502 Sep, 2025 NA
Tender For procurement of spares for mi-17 helicopter - hose, tip, gear, spline shaft, strap pedal, spring, pulley, anchores, unit, ring adjt, spring, dial, rod, inner cylinder with rest assy, spring, support (bracket), mounting, spring, support needle, shaft with blank, label, gasket, gasket, case, filter element, selector switch, air filter, funnel, flange, flange, flange, adopter, breaker, step, valve (unit), imidoflex space block (laying), lever, pilot seat/ co-pilot seat horizontal bowden cable, device, block, nozzle, potentiometer (from air conditioner set) v , casing front, sliding blister, emergency float system, receiver driver of yadro-1i, casing rotor, external fuel tank r , temperature control device cover

Central Government/Public Sector

CTN :40855454 Due date: 17 Jul, 202517 Jul, 2025 NA
Tender For supply of air conditioner , copper pipe , installtion of ac , voltage stabilizer , wall mount bracket
 Loading, Please wait...

Connect us via What's Up