Get complete information related to latest Surge Monitor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Surge Monitor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Surge Monitor Tenders.
Tender For supply of 42 kv, 10ka metal oxide gapless la with insulating base, surgemonitor and all other access ories as per rdso specification no. ti/spc/psi/mogtla/0101(02/2015 or latest. [ warranty period: 30 mo nths after the date of delivery ]
Tender For e-tender (2nd call) for procurement of laboratory instruments, equipment, appliances for the college of veterinary sciences and ah, rk nagar under the nec funded project for the year 2025-2026 - biosafety cabinetclassii, a 2 with accessories and power back up (bacteriology)-- the biological safety cabinet should be of class ii, type a2 designed in compliance with international standards the biological safety cabinet quoted instrument model must have international standards test likensf, tuv nord, en 12469 certification. certificate copy must be provided along with the technical bid. working area should be around 4foot. it should have exterior dimension w x h x d of 1300x 1568 x 800 and interior dimension wxhxdof 1200x 780x 630 it should have 1 piece grade 304 stainless steel or thermos scientific smart coat interior itshouldhavefeatureforpersonalprotection,sample protection, cross contamination protection and environmental protection. it must utilize brushless dc motor technology which uses significantly less energy with less heat emission provision compared to traditional ac motor technology to ensure lower levels of energy consumption. it should have 10 sloped front for exceptional comfort and ergonomics thesystemshouldbedesignedwithdualmotor. the motor must automatically adjust or control fan speed in real time to maintain constant airflow during filter loading or temporary obstruction. air flow direction: vertical laminar flow & air intake across front opening and 70% recirculation. filter: high performance particle air filter h14(hepa en1822), filtering efficiency 99.995% mpps or better. energy saving mode when cabinet not in use with maintaining sterility. continuous airflow helps to maintaina sterile environment, evenwhen the cabinet is not in use. thesystemshouldhaveindependentsensorstodetect pressure changes across the exhaust and down flow plenum/ air velocity and should indicate alarm signal when a 20-30% change in inflow/ exhaust or down flow occurs. control panel and performance monitor displays inflow/ down flow velocities, hours of use etc. to verify proper cabinet operation. frontglasswindowshouldbeeasilyloweredfor thorough smart cleaning of inner surfaces and designed to protect users by maintaining inflow, even when the window is lowered. the uv light must be quoted which should be programmable from 30 min to 24 hrs. in minimum 30 minutes increment to shut off automatically. the settings must allow the user to program the timer. the cabinet noise level must be less than 63 db(a) as measured in a sound proof room to promote more comfortable and safer working habitsof the user a per nsf/ ansi 49. the controller must be located on a slanted frontpanel so it is easy to see from a seated working position in front of the cabinet. control panel should be a large digital color touch screen display with health monitoring system, valuable safety and performance data with constant read-out of downflow/ inflow velocities and hours of operation in real-time, number of hours of use on the hepa filters. the front window sash must be angled 10 sloped front for operator comfort. two pieces of removable and autoclavable stainless steel arm rest should be provided for operator s comfort without disturbing the air flow. the system must have audio visual alarms to indicate when inflow is restricted and as well as whether front window is in correct position or not. theworkareashouldbeilluminatedwithswitchable fluorescent lamp of lighting power >120 fc or higher. suitable height floor stand without casters should be provided. in built access ports, 2 nos. (1 on each side) shouldbe available. it has single piece stainless steel work tray for easy cleaning and decontamination. warranty:minimum3year. electrical supply available: 230v a.c, single phase, 50 hz. bidder should provide printed brochure of the quoted model and details specification should be available in the manufacture website. customized model would not be accepted wi
Tender For corrigendum : procurement and supply of medical equipment for up gradation of pg seats in existing medical colleges in andhra pradesh (2 years rate contract) - coagulation and dissection electrode, instruments for laparoscopic, pyloromyotomy laparoscopic, instrument set metzenbaum, scissors micro mosquito, forceps palpation probes, telescope 5mm 30 degrees, telescope 10mm 30 degrees, trocars hd pediatric, colonoscopy system ebus-endo, bronchial ultra sound sleep lab level -ii, circumcision instruments- adult, circumcision instruments-, pediatric cystoscope , pediatric liithotripter, mono polar single stem turp, nephroscope - pediatric, oiu instruments (optical internal, urethrotomy) urethrotomes-, pediatric urethrotomes-adult, vac-machine with disposabled, vasectomy instruments, high speed drill in operation theatre, micro laryngoscopy, set rigid, esophagoscopy set rigid pediatric, bronchoscopy set simulators for ear,, nose surgeries sinus, endoscopy set oae, ent head light with led, stroboscope/ high speed camera, digital spectrophtometer(10, & 50 mm) digital flame, photometer pole climbing, apparatus mammalian heart, perfusion assambly autopsy examination, instruments autopsy examination, table bone cutting, oscillating saw tissue bath, 4 channel emg/ncv/ep, system polysomnography, video sleep study system (psg), carotid doppler, intra operative, doppler intra operative neuro, monitoring guided neuro, navigation system for cranial and spinal, applications cavitron ultrasonic, surgical aspirator (cusa), high speed electrical;, craniotomy/neuro drill system, operative microscope-neuro, stereotactic system spine endoscopy, neurosurgery instrument set, neuro-micro surgical instruments
Tender For repair of security equipment - repair of differential sound siren (a) replacement of circuit-01, repair of iron road barrier (a) replacement of wheel and welding-28, repair of bpgr (a) servicing of air conditioner -04 (b) repair of blower (pilibhit gate)-01 (c) filling of gas-04, repair of pre-fabricated guard cabin (a) re-wiring of pre-fabricated guard cabin -04, repair of mass alert system (a) replacement of battery-01, shifting of speed monitoring system (a) shifting of system with new pole-02
Tender For corrigendum : supply of surge arresters and accessories - supply 20ka nominal discharge, 25mm per kv creepage, 336kv 1ph, gapless zno sa complete with all acces corona ring, surgemonitor, ib, lugs, fixing and earthing hardware except tc and ic cable , supply 336kv tc suitable for twin acsr conductor , supply 10ka nominal discharge, 25mm per kv creepage, 216kv 1ph, gapless zno sa complete with all acces corona ring, surgemonitor, ib, lugs, fixing and earthing hardware except tc and ic cable , supply 216kv tc suitable for twin acsr conductor , supply 10ka nominal discharge, 25mm per kv creepage, 120kv 1ph, gapless zno sa complete with all acces cornona ring, surgemonitor, ib, lugs, fixing and earthing hardware except tc and ic cable , supply 120kv tc suitable for acsr moose , supply 10ka nominal discharge, 25mm per kv creepage, 30kv 1ph, gapless zno sa complete with all acces cornona ring, surgemonitor, ib, lugs, fixing and earthing hardware except tc and ic cable , supply 30kv tc suitable for acsr conductor , supply insulated copper rod strip or pvc insulated flexible copper cable connecting sa to surge counter , spares 20ka nominal discharge, 25mm per kv creepage, 336kv 1ph, gapless zno sa complete with all acces corona ring, surgemonitor, ib, lugs, fixing and earthing hardware except tc and ic cable , spares 336kv tc suitable for twin acsr conductor , spares 10ka nominal discharge, 25mm per kv creepage, 216kv 1ph, gapless zno sa complete with all acces corona ring, surgemonitor, ib, lugs, fixing and earthing hardware except tc and ic cable , spares 216kv tc suitable for twin acsr conductor , spares 10ka nominal discharge, 25mm per kv creepage, 120kv 1ph, gapless zno sa complete with all acces cornona ring, surgemonitor, ib, lugs, fixing and earthing hardware except tc and ic cable , spares 120kv tc suitable for acsr moose , spares surgemonitor