Get complete information related to latest Surgery Kit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Surgery Kit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Surgery Kit Tenders.
Tender For corrigendum : rate contract of ctvs items - rate contract of ctvs items :-, eptfe pericardial membrane 6.0 cm x 12.0 cms x 0.1mm, extra corpeal true membrane all size (complete set), eptfe pericardial membrane 12.0 cm x 12.0 cms x 0.1mm, expanded ptfe cardio vascular patch 0.5 mm size: 1.0 cms x 9.0 cm, expanded ptfe cardio vascular patch 0.5 mm size: 5.0 cms x 7.5 cm, expanded ptfe cardio vascular patch 0.5 mm size : 3.0 cms x 6.0 cm, expanded ptfe cardio vascular patch 0.4 mm size : 3.0 cms x 6.0 cm, expanded ptfe cardio vascular patch 0.6 mm size : 2.5 cms x 3.8 cm, expanded ptfe cardio vascular patch 0.6 mm size : 5.0 cms x 7.5 cm, ptfe ringed tubes it should be entirely made of ptfe it should not have an external wrap,it should have open pore. structure averaging 20 microns intermodal distance encouraging tissue ingrowth and making it soft and easy to suture.75cm long all sizes, bifurcated dacron tubes the prosthesis should used directly, without preparation before implantation the prosthesis should be strong, elastic, easy to pierce, and it should not fraythe wall should be provided with a colour guiding linewhen the prostheses are bent they should retain a lumen of circular shapethe water permeability should be 0-5 ml.cm-2.min-1should supplied in unit packagingit should sterilized by irradiation 50 cm long all size, dacron tubes the prosthesis should used directly, without preparation before implantation the prosthesis should be strong, elastic, easy to pierce, and it should not fraythe wall should be provided with a colour guiding linewhen the prostheses are bent they should retain a lumen of circular shapethe water permeability should be 0-5 ml.cm-2.min-1should supplied in unit packagingit should sterilized by irradiationall sizes 60 cm long, dacron tubes the prosthesis should used directly, without preparation before implantation the prosthesis should be strong, elastic, easy to pierce, and it should not fraythe wall should be provided with a colour guiding linewhen the prostheses are bent they should retain a lumen of circular shapethe water permeability should be 0-5 ml.cm-2.min-1should supplied in unit packagingit should sterilized by irradiationall sizes ,70 cm long, dacron patches (a) 1mm thickness implantable reinforcing felt for surgical applicationit should avoid possible incision of the stitchesit should be sterlized by radiationsize - 60 40mm, dacron patches (b) 1mm thickness implantable reinforcing felt for surgical applicationit should avoid possible incision of the stitchesit should be sterlized by radiationsize- 120 80 mm, knitted vascular patch with collagen (a) it should be easily cut to any shapeit should be strong elastic easy to pierce and it should not have frayit should be sterlized by irradiation sizes 100 100, knitted vascular patch with collagen (b) it should be easily cut to any shapeit should be strong elastic easy to pierce and it should not have frayit should be sterlized by irradiation sizes 13 80, knitted vascular patch with collagen (c) it should be easily cut to any shapeit should be strong elastic easy to pierce and it should not have frayit should be sterlized by irradiation sizes 13 100, knitted vascular patch with collagen (d) it should be easily cut to any shapeit should be strong elastic easy to pierce and it should not have frayit should be sterlized by irradiation sizes 35 100, valve implantation kit 1 kit, coronary surgery assistant kit 1 kit, complex congenital surgerykit 1 kit, venablock it should have 3cc of glue available in separate vials -it should have a catheter with a light source at the tip to assist in locating catheter tip position -it should have all accessories for injection of glue into applicator included - it should have ce and cdsco approval, atherectomy system -it should have infusion and aspiration port -it should be ready to use without any additional equipment -it should have adjustable rotational speed -it should have a 100cms catheter length, glow n te
Tender For corrigendum : supply of schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.) - schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.), polyster base round corner x-ray films (8" x 10") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (10" x 12") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (12" x 15") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, dental x-ray films intraoral periapcal the density values should blue base with base fog less than or equal to 0.20 & dmax not less than 3.10 the density values should be met at developer temperature 32 c to 35 c, liquid developer replenisher for automatic processor (starter solution, if recommended by the manufacturer, should also be supplied), ( price of item no. 5 and item no. 6 will be considered as a unit), liquid fixer hardner for automatic processor ( price of item no. 5 and item no. 6 will be considered as a unit), inj. meglumine diatrizoate sodium diatrizoate iodine content 365-375 mg/ml in 20 ml. ampoule/vial, pigtail angiography catheter with multiple side holes length 65 to 75 cm 5f, inj. gadolinium based contrast for mri for liver/liver specific (should provide details of compound being hepatobiliary specific), inj. gadolinium based contrast for mri for general use, inj. gadolinium based contrast for mri for angiography, disp lure lock syringes 3 ml. for glue injection, disp lure lock syringes 1 ml. for glue injection, x-ray folders laminated 250 gsm 14 1/2" x 17 ", dual pack 200 ml syringe with aspirator, "y" shaped coiled tube y-tube sterile, non-pyrogenic (minimum 300 psi & above) compatible with dual head pressure injector ( lf/medrad/ sea crown / spectra / apollo), extension "y" shaped coiled tubing for injector 150 cms. (-5 or +15cm) low pressure (minimum 300 psi & above), dual disposable syringes (60 to 65 ml each) with "y" or "t"shaped coiled tube connecting tubes small spike for contrast and large spike for saline compatible with mri injector (lf or medrad)., one way stopcock (high pressure), low pressure extension "y" or "t" shaped coiled tubing min. 150cms (-5 or +15 cms) with coiled connecting tubes & small spike for contrast & large spike for saline for medical mri injector., flavoured, ionic, water soluble, oral contrast iodine content 240-250 mg/ ml. in 30 ml, bernstein catheter 4 f 100 cm, bernstein catheter 5 f 100 cm, chiba needle 21 g 15 cms length, chiba needle 22 g 15 cms length, disposable c t scan pressure injector syringes (190 ml syringe + quick fill tube) for bayer medrad salient injector (toshiba / canon), extension "y" shaped coild tube adapter dual check valves (minimum psi 300 & above), nonionic iodixanol isoosmolar, 320 mg 50 ml, disposable mri syringes kit for 65/115 mr injector system 65 ml contrast syringes and 115 ml ns syringes with connecting tubing combo pack for spectris solaris medrad pressure injector, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 14 g & 10 cm in length, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 16 g & 10 cm in length, coil shape breast tissue marker with both front trigger & an alternate rear trigger, should be visible in ultrasound, mammography and mri, extension coiled tube with integr
Tender For supply of cavitron ultrasonic surgical aspirator (cusa) - supply of cavitron ultrasonic surgical aspirator (cusa), cavitron ultrasonic surgical aspirator (cusa) including:1) one angled/straight handpiece in the frequency range of 30-40khz for neuro application with tumor operating tips2) trolley should be supplied from same principal company3) torque wrench for handpieces- 1 no.4) infusion bottle holder- 1 no5) foot switch- 1 no6) instrument connection cables - 1 nos7) suction / irrigation tubing, -5 nos8) autoclavable compatible instrument tray 1 nos9) power cables 1, accessories (if required), one angled/straight handpiece in the frequency range of 30-40khz for neuro application with tumor operating tips, trolley, torque wrench for handpieces, infusion bottle holder, foot switch, suction / irrigation tubing, autoclavable compatible instrument tray, cmc charges for :, 6th year, 7th year, 8th year, 9th year, 10th year