Get complete information related to latest Switch Tripping Unit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Switch Tripping Unit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Switch Tripping Unit Tenders.
Tender For supply, installation, testing and commissioning of 33/11 kv, 3 mva outdoor transformer set, 33 kv indoor vcb switchgear panel board (1 i/c plus 2 o/g), 11 kv vcb switchgear panel board (2 i/c plus 1 b/c plus 6 o/g) including construction of electrical room at gc, crpf, prayagraj.
Tender For repair / maint of external lt supply, lt panel board, mccb, lt switchgear, starter, overhead line, power factor correction system and allied works at ch (cc) in the area of age e/m (hosp) under ge e/m lucknow
Tender For corrigendum : aoh of electrical equipment and auxiliaries of sstpp unit-1 of 2x600mw, sstpp, mppgcl, khandwa. - generator, misc works in generator overhauling, h2 purging after unit shutdown & h2 refilling before of unit light up., transformers, general overhauling of ht transformers, generating transformer(work description as detailed intender schedule), station transformer (work description as detailed intender schedule), inter-connecting transformer (work description as detailed intender schedule), unit auxiliary transformer (work description as detailed intender schedule), neutral grounding panel ( gen., gt, st, uats) {(work description as detailed intender schedule)}, general overhauling of lt transformers, lt dry type transformers (work description as detailed intender schedule), lt oil filled transformers (work description as detailed intender schedule), switchyard, breaker, isolators ,earth switch, bay equipments (cleaning & terminal tightness), bus ducts (work description as detailed intender schedule), 21/ 15.75 kv gen bus duct, 11 kv uat/st bus duct, 6.6 kv uat/st bus duct, lt transformer bus duct, esp, ltmsb & acp buses , ec panels & heater work (as per scope of work), ltmsb & acp breakers (as per scope of work), ltmsb & acp modules(as per scope of work)eerm=80 , cerm=80, gdrm=8, fields= 80, vfd supply=4, lighting supply & etc. = 25(approx), ht switchgear (11 kv/ 6.6 kv), bus cleaning , tightness & complete inspection of all buses., breaker cleaning, tightness & operation checking, bop switchgears panel / local control panels / wall mounted panels and 415v lt swbd/ mcc/acdb/dcdb switchgear panel, bus cleaning , tightness & complete inspection of all buses. breaker cleaning, tightness & operation checking, power house lighting & power supply, cleaning , tightness & complete inspection of all lightning transformers & ldb, providing power supply as per site requirement & for other maintenance work of bmd,tmd etc., ht motors, servicing of ht motors, ht motor cooler (general inspection & cleaning), lt motors servicing, motors above 40 kw, motor 40 kw to 11 kw, motors 10 kw to 5.5 kw, motors 5 kw to 1.1 kw, motors 1 kw and below, esp lt motors 1 kw and below, lt motor overhauling, motors above 40 kw(machining), motor 40 kw to 11 kw, motors 10 kw to 5.5 kw, motors 5 kw to 1.1 kw, motors 1 kw and below, servicing of dc bus, cleaning/servicing of 220 v dcdb buses & modules, servicing of soot blowers, servicing of soot blower motor 1 kw & below, servicing of soot blower panel/modules
Tender For corrigendum : providing of customized amc/cmc for pre-owned products - 9070c25c94 servicing of 6 point 6 kv and 11 kv abb make vd4 ht switchgear breakers and ht panel verticals through the oem at iocl paradip refinery and paradip petrochemical block on single tender proprietar..
Tender For supply, installation, testing and commissioning of 145kv sf6, 2500a bus coupler switchgear including cnr panel and allied accessories in the outdoor yard of 105 mw (3x35) ushp-ii, kangan hep
Tender For ttps es circle em ii external cleaning and attending minor maintenance works in electrical equipments such as power transformers rectifier transformer electronic control panels lt switchgear panel cable trays etc in esp i ii iii for the period f
Tender For ttps es circle em ii weekly cleaning, terminal tightness checking of ht lt motors lt switchgear panel contactor panels and external cleaning of electrical equipments cable tray cleaning works of ahp stage ii foph 1 dm plant clwph and ash dyke area
Tender For providing and fixing of switchgear in existing feeder panel near cpc canteen of 194 bn and generator room and providing earthing to feeder panel near mt garrage of 59 bn at seemanagar campus under shq bsf krishnanagar
Tender For suppl, installation and rearrangement of power switchgear panel along with allied works at bhandarwada hill reservoir under ae maint ww city ii section
Tender For - arc of electrical material. - electrical work :, providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 10% humidity 10% to 90% rh working temp -5c to 45c . driver current 750ma. the luminaire shall be bis certified and trade mark certified. life expectancy equal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. (lm79/lm80) certificate/ report with liable warranty of product/accessories from oem shall be submitted. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . led street light fixture with minimum lumen output 5600 lm, supplying and drawing of xlpe insulated lt aerial bunched aluminium conductor cable confirming to is 14255/1995 and is 398 (pt-4)/ 1994 and as per discom specs. on existing cross arms through i hook with all necessary t&p required including binding and twisting etc. complete in all respect as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . 1 x 25 sq. mm. + 1x25 sq. mm. (insulated), supply and fixing of 11 kv pin insulator confirming to is:731:1971 with latest ammendment on existing bracket including all accessories like ms forged hot dipped gi pin confirming to is 2486(part-i)/1993 & is:2486 (part-ii)/1989 with latest amendment, and as per latest discom specs. etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure a attached with this bsr, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . c