Tender For supply of vrf or vrv air cooled outdoor units suitable for cooling or heating having 100 percent hermetically sealed inverter type twin rotary or scroll compressor capacity of machines 14 hp to 22 hp , following minimum capacity 4 way vrv or vrf cassette type indoor ceiling mounted unit equipped with synthetic washable media pre filter,3 point 2 tr , following minimum capacity 4 way vrv or vrf cassette type indoor ceiling mounted unit equipped with synthetic washable media pre filter,4 tr , vaccumiazation and nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for vrv or vrf system, thickness 1 point 2 mm , 9 point 5 mm dia od soft drawn with tube thickness 1 point 2 mm , 12point 7 mm dia od soft drawn with tube thickness 1point 2 mm , 15 point 86 mm dia od soft drawn with tube thickness 1point 2 mm , 19 mm dia od hard drawn with tube thickness 1 point 2 mm , 22 point 2 mm dia od hard drawn with tube thickness 1 point 2 mm , 25 point 4 mm dia od hard drawn with tube thickness 1 point 2 mm , 28 point 58 mm dia od hard drawn with tube thickness 1 point 2 mm , 34 point 9 mm dia od hard drawn with tube thickness 1 point 62 mm , 41 point 27 mm dia od hard drawn with tube thickness 1 point 62 mm , s i t c of y joints kit refrnet , drain piping rigid pvc piping complete with fittings supports as per specifications and insulated with 6mm thick closed cell elastometric nitrile rubber insulation 25mm dia and , 32 mm dia , 40mm dia , control and transmission wiring , testing and commissioning of vrf or vrv systems including topping of r410a gas as per site requirements , supply and installation of u or v protection of used copper pipe at outer site for odu connection site , 6way load bank double door enclosure confirming to is 8623 iec 60439 g frame panel boards , supplying and fixing of following sizes of medium class pvc conduit along with accessories 25mm , frlsh or hffr pvc insulated copper conductor single core cable in the existing surface or recessed steel or pvc conduit as required 3 x 1 point 5 sq mm , suitable size gi box with modular plate and cover in front on surface or in recess , one number xlpe insulated and pvc sheathed copper conductor armoured power cable of 1 point 1 kv grade 4 x 16 sqmm , 16 a rating 240 by 415 v 10 ka c curve miniature circuit breaker suitable for nductive load of following poles in the existing mcb db complete with connections single pole , single pole and neutral sheet steel mcb distribution board 240 v on surface by recess complete 12 way double door , supplying and fixing 25 a rating single pole and neutral , following size of perforated painted with powder coating m s cable trays 150 mm width x 50 mm depth x 1point 6 mm thickness , earthing with g i earth pipe 4 point 5 metre long 40 mm dia including accessories , providing and laying earth connection from earth electrode , providing and fixing 6 swg dia g i wire on surface or in recess for loop earthing , amc as per section c , installation of cassette ac 2 ton 5 star , copper pipe , 4 core copper wire , drain pipe with insulation , odu stand , cable tray , hanging rod , faster nut , wrapping tape , 3 core copper wire
Tender For corrigendum : supply of 477510560160 - power distribution panel for qr sam , 477339970140 - power distribution panelcommunication , 477338810117 - radar pdu- 360x325x105mm
Tender For purchase of non-consumables for ece department - purchase, dual output regulated dc variable power supply input voltage: 230v/50 hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., function generator frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display. output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range. power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v overload protection. dc offset: 0 to 10 v adjustable. attenuation: 0 to 60 db., dso (digital storage oscilloscope) bandwidth: 50 100 mhz. sampling rate: 1 gs/s. channels: 2 (minimum). power supply: 100 240 v ac, 50 60 hz. automatic measurements: vpp, vavg, vrms, frequency, period, vmax, vmin, rise time, fall time, +width, width, +duty, duty, etc. horizontal scale: 5 ns/div 50 s/div or equivalent. vertical resolution: 8 bits (2 channelssimultaneously). vertical sensitivity: 1 mv/div 10 v/div (at input). waveform math: +, , , , invert, fft, etc. waveform storage: 16 waveforms or equivalent. communication interface: usb host and usb interface. display: 7-inch color display or equivalent. input impedance: 1 m 2% || 20 pf. accessories: 2 passive probes (1x/10x)., digital ic trainer kit with breadboard +5 v dc, 1 a regulated power supply. 12 v dc / 15 v dc, 200 ma regulated power supply. solderless breadboard with minimum 840 tie points,power distribution buses. zif (zero insertion force) ic sockets to accommodate 8 or 16 pin ics. logic input and output leds for output monitoring. 16 buffered led outputs. 16 debounced switch inputs. variable clock generator: 0.5 hz to 50 hz. single pulse output: 100 ms (buffered, positive and negative outputs). one seven-segment display with 4 bcd inputs. built-in logic switches. manual clock: debounced push-button (one pulse per press)., lvdt trainer kit ac mains power supply: 230 v 10%, 50 hz. fixed regulated dc power supply: +5 v, 12 v / 500 ma. transducer: lvdt. lvdt displacement: 20 mm (40 mm total). displacement scale: linear 20 mm. displacement display: red color 3 digit led display. excitation frequency: 4 khz. excitation voltage: ac variable excitation voltage up to 5 v., strain guage trainer kit ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords and user manual.
Tender For supply, installation and testing of electronic equipments - supply -ece lab equipments, single output regulated dcvariable power supply- input voltage: 230v / 50hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., dual output regulated dc variable power supply- input voltage: 230v/50 hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., function generator - frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display. output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range. power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v, digital ic trainer kit with breadboard - +5 v dc, 1 a regulated power supply. 12 v dc / 15 v dc, 200 ma regulated power supply. solderless breadboard with minimum 840 tie- points,power distribution buses. zif (zero insertion force) ic sockets to accommodate 8 or 16 pin ics. logic input and output leds for output monitoring. 16 buffered led outputs. 16 debounced switch inputs. variable clock generator: 0.5 hz to 50 hz. single pulse output: 100 ms (buffered, positive and negative outputs). one seven-segment display with 4 bcd inputs. built-in logic switches. manual clock: debounced push-button (one pulseper press)., dc voltmeter(digital) - dc digital voltmeter - 3 digit led/lcd display, measurement range: 0 20 v dc,accuracy: class 0.5( 0.5 % full-scale), dc ammeter - dc ammeter digital - 3 digit led/lcd display, measurement range: 0 5 a dc,accuracy: class 0.5 ( 0.5 % full-scale), lvdttrainer kit - ac mains power supply: 230 v 10%, 50 hz. fixed regulated dc power supply: +5 v, 12 v / 500 ma. transducer: lvdt. lvdt displacement: 20 mm (40 mm total). displacement scale: linear 20 mm. displacement display: red color 3 digit led display. excitation frequency: 4 khz. excitation voltage: ac variable excitation voltage up to 5 v., strain gauge trainer kit - ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. instrumentation amplifiers with 3 digit display for strain / output voltage. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords and user manual., ask modulation and demodulation kit - message signal1:8-bit variable data,amplitude 5v. message signal 2:debounced data, amplitude low (0) and high (5 v). message signal 3:fixed data 25 khz, 12.5 khz, 6.25 khz, 3.12 khz,amplitude 5 v. carrier signal: sine wave, frequency 200 khz, amplitude 5 v. supply voltage (board): +12 v, +5 v dc. input voltage: 230 v ac, 50 hz. interface connectors: 2 mm banana socket., fpga trainer kit - must use industry-standard mid-range fpga device usb-jtag programmable, compatible with vivado ise (webpack). power supply: 5 v dc through usb or external adapter. on-board peripherals: leds, switches, push buttons, 7-segment display,clock source, gpio / pmod expansion ports, uart, vga / hdmi, usb- uart bridge, usb cable. user manual., measurement scale: a vertical steel meter scale, usually with (1mm) graduations, for precise deflection measurement., accessories: includes a set of slotted weights (e.g., (6times 50g) or similar sets) for incremental loading.
Tender For supply and installation of lt panel at ozone switchgear, relocation of power supply distribution panel and laying of power supply cables to office, colony, canteen, pump house at yccp plant, yelahanka
Tender For renovation work of electrical installation in admin block, workshop and washing plant at dtc seemapuri depot. - wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required., wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required., group c, wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required., wiring for light/ power plug with 4x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 2 nos. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required., wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required., 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire, 2 x 6 sq. mm + 1 x 6 sq. mm earth wire, 4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire, supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/recessed steel/ pvc conduit as required., 5 x 4 sq. mm, supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required., 32 mm, supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., 5/6 a switch, 15/16 a switch, 3 pin 5/6 a socket outlet, 6 pin 15/16 a socket outlet, supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required., 3 module (100 mmx75 mm), 6 module (200 mmx75 mm), 8 module (125 mmx125 mm), 12 module (200 mmx150 mm), supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 a & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required., supplying and fixing 3 pin, 5 a ceiling rose on the existing junction box/ wooden block including connections etc. as required., wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed pvc conduit, and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc. as required., group c, providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required., 150 a, 16 ka,tpmccb, 100 a, 30ka, fpmccb, supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator), 12 way, double door, supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copp