Tender For set of 02 cab ac items components consisting of (1) blower motor with double extended sha ft with fan impeller for air conditioning unit, frame 63, frequency-50hz +/- 5%, volts 415 +/- 10%, rpm: 13 60 with test certificate, as per rdso specification no. rdso/pe/spec/ac/0089, rev-0/ amendment no.1 or i ts latest- 05 nos. (2) condenser motor 0.15kw, frequency-50hz, frame 63, supply 415v ac +/- 10%, 0.7 a mps rpm: 1350, star connection, reference is: 325- 05 nos. for roof mounted packaged ac unit electric lo cos. note: (1) test certificate should be provided by firm along with the material. (2) the firms with past pe rformance of the tendered/same items subject to submission of proof of documents such as pos/r note are only eligible [ warranty period: 30 months after the date of delivery ]
Tender For supply of mt store d d - condensor assy , intel line pipe , out line pipe , copressor assy , pressure control valve , fan belt , blower motor , clip , plug oil drain , belt alternator , cabin air filter , belt water pump , wiper blade assy
Tender For corrigendum : supply of ems service te railwaypura - pvdg reneted oump for use , replace 50mm gi b class pipe , sf 3inch half turn valve gi , sf 2inch half turn valve gi , modify 3inch water line by pvdg 3inch flange , modify 3inch water line by pvdg 3inch nipple , modify 3inch water line by pvdg 3 inch tee , modify 3inch water line by pvdg 2.5 inch nipple , modify 3inch water line by pvdg 3 and 2.5 inch socket , modify 3inch water line by pvdg 2.5inch coupler , modify 3inch water line by pvdg 2 inch nipple , modify 3inch water line by pvdg 2 inch tee , sf 50 mm nrv , plumbing work for priming assembly , arrangement of automationof extg water supply by pvdg 5 hp dol starter , arrangement of automationof extg water supply by pvdg 63a 4p changeover mcb , arrangement of automationof extg water supply by pvdg auto timer 24 hrs , arrangement of automationof extg water supply by pvdg wlc , arrangement of automationof extg water supply by pvdg 63a 4p mcb , arrangement of automationof extg water supply by pvdg 3.5c 50 sq mm et , arrangement of automationof extg water supply by pvdg 200 a terminal , sitc 10kvar app capacitor , rewind ex fan ped fan motor upto 200w , rewind ceiling fan motor upto 1400 mm , replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , replace 2 module electronic regulator , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , conduct fire drill for bldg g plus 3 flr , service 11kv substation with ht panels , repair of substation panel by repacing led ind lamps 220v , repair of substation panel by repacing 2 to 4 a hrc fuse , repair of substation panel by repacing lml1 contactor kit , repair of substation panel by repacing bimettalic ol for blower mn2 , repair of substation panel by repacing spp ol relay mpr1 , repair of substation panel by repacing 8 pin 220v pla relay , repair of substation panel by repacing 0 to 400a ammeter ac , repair of substation panel by repacing 0 to 30 a ammeter ac , repair of substation panel by repacing 0 to 500v voltmeter ac , repair of substation panel by repacing dc ammeter 96mm , repair of substation panel by repacingdc voltmeter 96mm , repair of substation panel by repacing selector switch , b check service of dg set 320 kva , supply smps battery charger 24v 10a , sf 12v 130ah mf battery for ea set , supply brass battery terminals , pvdg led ind lamps 220v ea set , sfixing bradided fuel pipe for ea
Tender For corrigendum : supply of replacing in 1.5or2tr ac unit blower fan motor , replacing in 1.5or2tr ac unit blower drum , replacing in 1.5or2tr ac unit condenser motor , replacing in 1.5or2tr ac unit condenser fan blade , replacing in 1.5or2tr ac unit pcb of indoor , replacing in 1.5or2tr ac unit pcb of outdoor , replacing in 1.5 ac unit rotary compressor 1.5tr , replacing in 2.0 ac unit rotary compressor 2.0tr , replacing in 1.5or2tr ac unit capacitor 25 35 5 mfd , replacing in 1.5or2tr ac unit 25a 2 pole contactor , replacing in 1.5or2tr ac unit terminal box 6w , water service of 1.5 or 2 tr ac units , blower service of 1.5 or 2 tr ac units , gas charging r22 r 134 of 1.5 or 2 tr ac units , replacing 50mm thick filter , s f of auto controller of 2 ac , replacing 25a spn mcb , site visit for ac repairing
Tender For supply of blower fan motor having double end extended shaft for sidwal/intec / fedders lloyd ma ke rmpu of lhb type ac coaches 1.1 kw, 415v, 3 phase, 50 hz, 1500 rpm as per rdsos specification no. rdso/pe/spec/ac/0089-2008 (rev. 0) with amendment no. 1 & 2 suitable for foot mounting. [ wa rranty period: 30 months after the date of delivery ]