Get complete information related to latest Tail Lamp Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tail Lamp Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tail Lamp Scrap Tenders.
Tender For supply of following items for setting up measurement and instrumentation lab for 4 year b.tech in electrical engineering curriculum and application for university of calcutta. - experimental set-up for calibration of a wattmeter using dc potentiometer with following features/items:regulated power supply 2 volts, 100 ma to operate the potentiometer.calibrated electronic standard cell voltage 1.0186 volts.regulated power supply 0-5 volts/0.5 amps with milliammeter 0- 500ma for current coil of wattmeter.regulated high voltage power supply 0-250 dc volts with voltmeter 0-250 volts for pressure coil of wattmeter.a panel mounting wattmeter 0-125 watt is required to perform the experimentgalvanometer for null balance.a volt ratio box for measurement of higher voltage.complete circuit diagram with wattmeter connections to be provided on the front panel of the instrument.with standard accessories, experimental set-up for low resistance measurement using kelvin s double bridge with following features:range: 0.2 micro ohm to 11 ohms, with an accuracy of 0.05 %required accessories:spot reflecting galvanometer. dc source 10 a with one analog current meter. attachment of 1 meter length.brass clamp with terminals for zero setting. with standard accessories, experimental set up for unknown capacitance measurement using de-sauty s bridge with following specifications:source: sine wave signal of 1khz. the amplitude of ac switch indicating lamp is provided on the bakelite board. two sockets are to be provided for the output of ac signals.detector: for detecting small ac signals in the output, null detector is required as in-built with digital display.circuit diagram:the circuit layout on the board is to be provided out to facilitate convenient working. 4 or 5 mm socket required for making connection. features:r2 --- three decade resistance dials having value 10 1000, 10 100 and 10 10 ohmsr1 ---- single decade resistance dial having value 10 100 ohmsc1 ---- unknown capacitor.c2 ---- two fixed standard capacitors having value 0.01mfd 0.1mfd (loss free)with standard accessories, experimental set-up for calibration of a 1-phase watt-hour meter with following scopes: to adjust & calibrate a single-phase energy meter by direct loading method to adjust & calibrate a single-phase energy meter by comparing with a sub-standard meterspecifications: static energy meter single phase: under test (local) duly mounted, wired and terminated static energy meter single phase: sub-standard meter (isi mark) duly mounted, wired and terminated voltmeter: moving iron ac portable of class 1.0 accuracy and range 0 - 300 v ac ammeter: moving iron ac portable of class 1.0 accuracy and range 0 - 10 a ac wattmeter: dynamometer type ac single phase, multi-range with current coil 5 / 10 amp and potential coil 75 / 150 / 300 v ac variac: variable voltage transformer (portable table / floor mounting type with enclosure) input: 230v ac and output: 0 270v / 8 amp ac variable load: made up of 3 load resistors of 70 ohms / 700 w each duly mounted and connected / terminated to form different loads (35 to 210 ohms) as per external connections digital stop clock: portable with start / stop & reset operation set of necessary 4 mm spring loaded patch cords for interconnections detailed instruction manual supply to be connected: 230v, 1phase, 50 hz, ac mains, experimental set-up for calibration of a 3-phase watt hour meter with following specifications: to adjust & calibrate a three-phase energy meter by direct loading method to adjust & calibrate a three-phase energy meter by comparing with a sub-standard meterspecifications:static energy meter three phase: under test (local) duly mounted, wired and terminatedstatic energy meter three phase: sub-standard meter (isi mark) duly mounted, wired and terminatedvoltmeter: moving iron ac portable of class 1.0 accuracy and range 0 - 300 v acammeter: moving iron ac portable of class 1.0 accuracy and range 0 - 10 a acwattmeter:
Tender For corrigendum : supply of spares f for alind make 33 kv oil circuit breaker - heavy duty numerical relay with 3 o-c an, part no. ald6656 , facia annunciator and hooter, part no.ald6670 , master trip relay, part no.ald6634 , power pack unit for emergency backup, part no.ald6644 , mimic diagram and semaphore indicator, part no.ald6612 , indicating lamp fitting complete set, part no.al10092 , oil tmprtr alrm-trip relay, part no.al80617 , spring charging motor, part no. al37021 , closing coil assembly, part no.al37024 , tripping coil assembly, part no.al37025 , breaker control switch-tnc switch, part no.ald6025
Tender For corrigendum : supply of spares of electrical panel accessories for csctpp, chhabra - led indication lamp sr. no. a1 to a6 , led indication lamp sr. no. a7 to a10 , led indication lamp sr. no. a11 to a15 , led indication lamp sr. no. a16 to a18 , flush type push button sr. no. c3 to c5 , push button with led indicating lamp sr. no. c6 & c7 , emergency stop push button sr. no. c8
Tender For corrigendum : tender for supply of suction gas strainer , star delta timer(3-60sec) 240v ac 50hz , high pressure switch kp-5 (reset type) , 4inch dial presure gauge , tube cleaning brush , gauge grid(wmo) , of aux switch , temperature indicator (0-100inch c) , contactors rated 10 a , 240v ac coil with 1no+1nc contact , oil filter for ac compressor , solenoid valve evr 20-1.5/8inch , thermostatic expansion valve model ten55 , globe valve 3.5/8 , angle valve 1/4inch , contactor with coil , mechanical seal , low pressure switch kp-1 , solenoid coil 230 v (unloader) , oil solenoid valve , bearing of 3 phase motor , bearing of 3 phase motor , motor protection relay , drier core (r134a) (48-dc) , oil thermostat , drier with core , return air thermostat (kp-69) , water pressure switch (kp-1) , set of gasket(both ends) , flexible hose , oil filter with o ring , coupling ks 720 , selector switch with 2 maintain position with 1 no contact , mechanical seal for ac seawater pump , butter fly valve 65 mm nb , oil filter with o rings , discharge/oil temperature safty , globe valve 2.1/8 , punkah louver , indicating lamp integral led red colour 230v , v belt , under voltage relay 415v , 50 hz , gasket set , triple pole miniature circuit breaker rated 32a , clip on type terminal 16 sq mm , bi metallic o/l relay range 37-50a , ac compressor oil level control , contactors rated 18 a , 240v ac coil with 1no+1nc contact , gauge grid , hp cut out , impeller for model naf/315/150/10 , ahu filter element 550x480x50 mm , contactors rated 9 a , 240v ac coil with 1no+1nc contact
Tender For supply of welding rod , brush electrical contact , rectifier 1400 piv 10 a bridge rectifier slip ring avr 380 vcd transformer repalcement , core assy transformer , board terminal bakelite 1900mm x 70mm x 6mm thick , strip terminal 12 ways , mounting antivibration resilient doble u shear , voltmeter mi type 0 to 300v ac 96sqmm 1 point 5 flush mtd , socket electrical 3 pole 30 amp 500v with cap and chain , socket electrical 3 pole 15 amp 250v with cap and chain , socket electrical 2 pole 5 amp 250v with cap and chain , switch rotary 2 pole 16 a 250vac , switch rotary 4 pole 40 a 250vac , ac ammeter moving iron type 0 to 40 amp 96 sqmm class 1 point 5 , meter electrical frequency reed type 47 to 50 to 53 hz 96 sqmm , switch push button green star push button no to nc green , switch push button red star push button no to nc red , time totalizer 50hz 5 digit with reset to recd hours , indicating lamp supply on 230 v ac and set running , indicating lamp for charging failure 12v ac , indicating lamp lop 12 vac , shourd panel lamp 12 vdc 3 point 5 w , cable control assy for eng stop stopper cable , fuse 32a 250 vac hrc , fuse 16a 250 vac hrc , fuse link electrical cartridge 440v 6a , relay armature plug in type miniature 2 co 12 vdc 8 pin relay with socket 12 vcd , transformer step down 0 to 220 to 230 to 240 to 250v primary and 0 to 15vac 5 amp supply secondary , semiconductor device diode type 20ussr6 6amp , disc flexible lf to 225 , wheel ball valve 1 oblique 4 inch bsp thread , fuel gauge elect float type , lead secondary battery positive 933 point 5mm long , lead secondary battery negative 933 point 5mm long , fuse link electrical cartridge 440vac 6a , pipe flexible 60 inch long , tape insulation 1 point 25mm and 10 m long , element lub oil filter spin on type , element fuell filter pre , element secondary fuel filter , pipe flexible 12 point 5 inch long , fuel pipe flexible 30 inch long , fuel pipe flexible 35 inch long , dc on oblique off switch 16 amp 2 pole , decompressor shaft and lever assy , eng oh gasket set complete , anti vibration mtg pad rubber ms plate , oil seal fwe , oil seal ge , silencer exhaust , nozzle fuel injector , pump fuel injection , plunger fuel pump tappet , joint fuel pump , 4 st relay , engine protection unit engine safety unit , engine stop solenoid 12 vdc , pvc chanels for cables caping and casing , din rail , screw for rail bid details/ 2 / 43