Web Analytics Made Easy - StatCounter

Tandem Rig Tenders

Get complete information related to latest Tandem Rig Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tandem Rig Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tandem Rig Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :43188296 Due date: 31 Dec, 202531 Dec, 2025 13.65 Crore
Tender For providing of handling ,transport and other mining services - percentage quote based - ob removal, hiring of hemm for excavating rehandling ob not requiring drilling loading into tippers transportation and unloading the excavated material at kusmunda area

State Government

CTN :43182279 Due date: 02 Jan, 202602 Jan, 2026 NA
Tender For extension of exploratory drifts dl-2 and dl-8 of size 2.1 m x 2.1 m, total length 235m, in all kinds of rock including soft rock zones and shear zones by drilling and blasting, providing supports if required and arrangements for lighting and ventilation, where necessary, mucking out the excavated material and disposing it in regular layers complete with all lifts and leads at the identified dumping areas for renukaji dam project, hppcl, dadahu in distt. sirmaur, hp

State Government

CTN :43158199 Due date: 17 Dec, 202517 Dec, 2025 3.00 Crore
Tender For annual rate contract for the work of construction of 125 mm dia tube well by dth drilling rig, supply &amp instalation of india mark-ii hand pump set including other required material under jurisdiction of circle sirohi district sirohi

State Government

CTN :43117906 Due date: 15 Dec, 202515 Dec, 2025 NA
Tender For drilling and establishment of handpump with material for division office rewa and all ranges

State Government

CTN :43132463 Due date: 06 Jan, 202606 Jan, 2026 2.50 Crore
Tender For drilling of 125 mm dia meter bore holes for hand pumps and installation of india mark ii hand pumps complete with platform (material) under division karauli in all type of strata on annual parallel rate contract basis

State Government

CTN :43132481 Due date: 06 Jan, 202606 Jan, 2026 2.50 Crore
Tender For drilling of 125 mm dia meter bore holes for hand pumps and installation of india mark ii hand pumps complete with platform (material) under division hindaun city in all type of strata on annual parallel rate contract basis

Central Government/Public Sector

CTN :43111326 Due date: 30 Dec, 202530 Dec, 2025 NA
Tender For tender for supply of supply and installation commissiong d d -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1392 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply the indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1 2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required , supply and fixing of 75mm dia minimum 18mm thickness pvc covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25 x 25x5mm l angle frame including clamps bolts nuts vibrating dampers as required , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealed scroll rotary compressor and eco friendly refrigerant initial charge of refrigerant condensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor laying and interconnection of standard length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of beyond the standard length supplied by the oem copper refrigerant pipe of size suitable for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation for hi wall split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 75mm dia minim

State Government

CTN :42813292 Due date: 15 Dec, 202515 Dec, 2025 NA
Tender For corrigendum : tggenco-ytps(5x800mw)-supply of t and p items required for stage-i and chp of ytps. - ac/dc volts (40hz to 500hz):4.000v, 40.00v, 400.0v, 1000v; resistance (ohms): 400.0 ohm, 4.000 kohm, 40.00 kohm, 400.0 kohm, 4.000 mohm, 40.00 mohm; capacitance: 40.00nf, 400.0nf, 4.000 µf, 40.00 µf, 400.0 µf, 1000 µf; ac/dc current: 4.000a, 10.00aac/dc millivolts: 400.0mv; diodetest: 2.000v;ip rating: ip40safety: iec 61010-1, iec 61010-2-030 cat iii 600v, cat ii 1000v, pollution degree 2.temperature: 50-400°c, 0-50°c, -55 to 0°c.temperature: operating: 0°c to 40°c;storage: -30°c to 60°celectromagnetic environment: iec 61326-1:portableincluded accessories: test leads with caps, thermocouple, temperature probe, 2 aa batteries, user manual along with the required calibration certificates.gds 18v-400 cordless impact wrench;battery voltage: 18v; torque max: 400nm; no load speed: 0-3,400 rpm. make: boschfluke true rms ac/dc digital clamp meter with iflex probe and fluke connect modelno: 376digital multimeter, make: fluke, model: 17b+, specifications: ac/dc current 10 amps, ac/dc voltage 1000 voltsmegger, 1kvleakage current clampmeter ac, range (0-100a)portable hot air blowervacuum cleaner, dry, 1300w, 6.1kg, 230v, 50hzvibration meter, digital, model: ird 306analog phase sequence indicator, 100 to 500 v, 25 to 65 hzdigital earth resistance tester with resistivity test facility, earth resistance: 0.01 ohms-200 kohmsplier, nose, 6"/150 mmhammer, 4 lbcutting plier, 12"39 , gds 18v-400 cordless impact wrench; battery voltage: 18v; maximum torque: 400 nm; no load speed: 0-3,400 rpm. make: bosch. , fluke true rms ac/dc digital clamp meter with iflex probe and fluke connect, model no: 376, , digital multimeter, make: fluke, model: 17b+, specifications: ac/dc current 10 amps, ac/dc voltage 1000 volts, , megger, 1kv, , leakage current clamp meter ac, range (0-100a), , blower, portable hot air, , vacuum cleaner, dry, 1300w, 6.1kg, 230v, 50hz, , vibration meter, digital, model: ird 306, , analog phase sequence indicator, 100 to 500 v, 25 to 65 hz, , digital earth resistance tester with resistivity test facility, earth resistance: 0.01 ohms–200 kohms, , plier, nose, 6"/150 mm, , hammer, 4 lb, , cutting plier, 12", , tape, measuring; length: 3 m; material: steel, , tape, 5 meters measuring tape, , tape, 30 meters measuring tape, , hole punch set 22, 20, 18, 16, 14, 12, 10, 8, 6, 4 set of 10 nos (tiger make), , center punch, length: 125 mm, , drilling machine, rated power input: 800w, 240v, drilling diameter in concrete with hammer drill bits: 4-26 mm, , digital motor checker: emc-38, , transformer, auto; type: manual operated variable; input voltage: 240 vac; output voltage range: 0-270 v ac; special features: (dimmerstat) with continuously variable banana terminals, capacity: 20 amps; model: 20d-1p, , transformer, auto; type: manual operated variable; input voltage: 415 v ac; output voltage range: 0-470 v ac; phase: 3; special features: 50 hz; model: 15d-3p, , lux meter, digital, 0-50,000 lux with silicon photodiode sensor, lcd display, dc 9v battery, mandatory accessories, , tachometer, digital; speed range: 9999/99999 rpm; model: v, , digital micro ohm meter, model dmo-100d, , gun, laser, , specifications:, , laser convergence distance: 50" (127cm) ir range: -58 to 3992°f (-50 to 2200°c) emissivity: 0.10 to 1.00 adjustable, , max resolution: 0.1°f/°c, , field of view (distance to target): 50:1

State Government

CTN :42814845 Due date: 22 Dec, 202522 Dec, 2025 1.50 Crore
Tender For corrigendum : nit 12 rate contract for drilling of 125 mm diameter bore holes for hand pumps and installation of india mark ii/iii hand pumps complete with platform (with material) in all type of strata for phed district rural division-ii district jaipur

Central Government/Public Sector

CTN :43057383 Due date: 18 Dec, 202518 Dec, 2025 NA
Tender For supply of slack adjuster assembly (upper) to rdso drg. no.-skvl-189 alt.-1 &rdso drg. no.-skvl-190 alt-1 with bushes alone to material mn steel toirs-r65/78. i. item no.03 of rdso drg no.-skvl- 189 alt-1 is required as per clwdrg no.06/4/19/147 alt.-1. ii. two nos. of roll pins to ref. no.09 of drg. no. skvl-189 to be fixed by drilling on the block at both sides of the adjusting bolt tail end to createefficient locking mechanism.
 Loading, Please wait...

Connect us via What's Up