Get complete information related to latest Target System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Target System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Target System Tenders.
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be
Tender For repair / replacement of internal unserviceable point wiring / fitting / fixture and connected accessories work in karam singh enclave and bana singh enclave under age e&m-iv of ge (south) bathinda at bathinda mil stn - taking down carefully existing copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, bell pushes, ceiling roses, pendants, regulators, sockets, light fitting, call bells etc. removing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. to match existing colour complete all as specified and directed., material and labour for concealed one light / fan point controlled by one, one way modular switch 06 amp wiring with 1.5 sq mm nominal cross sectional area, single core, 1100 volt grade, multi-stranded, pvc insulated, unsheathed frls copper conductor cable with and including continuous earth wire of size 1.5 sq mm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, pvc insulated, unsheathed, frlsh copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic pvc conduit of 20 mm dia in medium grade complete with and including all pvc conduit accessories concealed into wall by cutting of chases in wall complete and including modular metal flush boxes not less than 1.6mm thick alongwith modular cover plate with frame of any size for mounting of any type modular switches/sockets/bell switch /fan regulator and brass screws, cup washers etc complete, making good the distributed surfaces completely matched and finished with existing surface including painting of walls etc complete all as specified and directed. , all as per srl item no. 2.00 (here-in-before) but one 3 pin socket outlet 6 amp on same board point, complete all as specified and directed, all as per srl item no. 2.00 (here-in-before) but one 3 pin socket outlet 6 amp on the independent board point with pvc fr-lsh cable size 2.5 sqmm complete all as specified and directed., all as per srl item no. 2.00 (here-in-before) but one bell point controlled by one bell push on independent board complete all as specified and directed., all as per srl item no. 2.00 (here-in-before) but one light point controlled by two way switch complete all as specified and directed., all as per srl item no. 2.00 (here-in-before) but for 15/16 amp socket out let/power point by using 2.5 sqmm pvc insulated unsheathed copper conductor cable fr-lsh multi strand on independent board including provn of 2.5 sqmm unsheathed, multi stranded copper conductor cable fr-lsh continues as earth wire connected to earth dolly etc complete all as specified and directed, all as per srl item no. 2.00 (here-in-before) but for 15/16 power point (ac & geysers) by using 4.0 sqmm pvc insulated unsheathed copper conductor cable fr-lsh multi strand on independent board including provn of 4.0 sqmm unsheathed, multi stranded copper conductor cable fr-lsh continues as earth wire connected to earth dolly etc complete all as specified and directed, material and labour for one light / fan point controlled by one, one way modular switch 06 amp wiring with 1.5 sq mm nominal cross sectional area, single core, 1100 volt grade, multi-stranded, pvc insulated, unsheathed frls copper conductor cable with and including continuous earth wire of size 1.5 sq mm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, pvc insulated, unsheathed, frlsh copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and in existing rigid non-metallic pvc conduit including modular metal flush boxes not less than 1.6mm thick alongwith modular cover plate with frame of any size for mounting of any type modular switches/sockets/bell switch /fan regulator
Tender For repair replacement of internal unserviceable point wiring fitting fixture and connected accessories work in tarapore enclave, khetrapal enclave and abdul hamid under age em iv of ge(s) bathinda at bathinda mil stn - taking down carefully existing copper/aluminum point wiring (light,fan, socket or power) complete including fixture and fittings such as switches, bellpushes, ceiling roses, pendents, regulators, sockets, light fitting, call bells etc removing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. to match existing complete all as specified and directed., m & l for point wiring with multi-stranded copper conductor, single core, pvc insulated and unsheathed cable, including pvc insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, gi terminal boxes, modular frame & cover plate (suitable for modular switch/sockets) comprising the following: -, one light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit all as specified., one socket outlet three pin, 6 amp, on the same board, with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, all as specified, one socket outlet three pin, 6 amp, independent, with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit all as specified., one bell/buzzer point controlled by one push button with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit all as specified, one light point controlled by two way switch. with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit all as specified., one socket outlet three pin, 5/15 amp, independent, with 2.5 sq. mm (nominal area) cable & 2.5 sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit all as specified., one light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic pvc medium duty concealed conduit all as specified., one socket outlet three pin, 6 amp, on the same board, with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, all as specified., one socket outlet three pin, 6 amp, independent, with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic pvc medium duty concealed conduit all as specified., one socket outlet three pin, 5/15 amp, independent, with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic pvc medium duty concealed conduit all as specified., one bell/buzzer point controlled by one push button with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic pvc heavy duty concealed conduit all as specified., m & l for inverter wiring with multi-stranded copper conductor, single core, pvc insulated and unsheathed cable,one light point /one 5 amp socket point only.including drawn though pvc conduct all as specified and as directed., s&f switch modular type single pole, one way, 6 amp, one module, complete all as specified., s&f switch modular type single pole one way, 16 amp, one module, complete all as spe
Tender For supply of sports shot auto manual targetsystem , point 177 precihole px 50 indian air pistol , point 177 precihole px 100 peep sight air rifle , point 177 sports shot indian pellets tin , r 10 pellets , rifle shooting kit jacket trouser gloves inner upper inner lower shoes size 6 7 8 and 8 cap timer , pistol kit shoes 6 7 8 and 9 cap and timer , sports shot air rifle targets , sports shot air pistol targets , 300 bar big cylinder , sports shot rifle stand , kneeling roll with cork sports shot , point 177 walther lg 400 alutec electronic air rifle , point 177 morini walther air pistol , electronic target machine sius with all accessories , acp fitted metal table size 13x1 25x3 shooting table as per issf specification 127 sq fr wooden furniture optional , back board area made of 2x2 eposy coated ms pipe structure covered with 18mm cement sheet and 1 pine wood strip size 13x10 as per issf specifications 130 sq ft , 18mm cement sheet partition including sliding door size 38x 8 as per issf specification 304 sq ft , window sheet fixture size 4x6 as per issf specification 10 set , non woven green color carpet with fitting as per issf specification 735sq ft , 24 led light with all required electric wiring as per issf specification , 1 point 5 ton split air conditiner with fitting as per issf specification , painting and finishing as per issf specification , tara flex 12 ft x 3 ft as per issf specification antiskid flooring