Get complete information related to latest Techno Economic Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Techno Economic Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Techno Economic Tenders.
Tender For augmentation of dda parks (as per inventory attached) with 4 mtr. poles ,45 watt led street light ,100 watt flood light alongwith allied accessories i/c supply, installation, testing and commissioning of pumpsets suitable for sewage water for horticulture purpose under hd-8.
Tender For supply, installation, testing and commissioning of electro-mechanical works to be executed at water supply facilities of hirpora banimulla for source sustainability under ut capex.
Tender For khajpur , gurukul , naya gaon , group of 3 no. of habitations annual mtc.works for water supply - na installation of shallow/medium/deep tubewells as per is 2800:1991 supplying, erection, testing and commissioning of submersible pumping sets as per bis specification no. 8034-1989 (as amended upto date for pumps) and is 9283-1979 (as amended upto date for motor) the pump motor sets should be capable of pumping clear fresh cold water having characteristics as specified in clause-4 of is 8034-1989 and clause 4.1 of is 9283-1979. 1. lpm 400 head 70 bhp 10.37 say round bhp 10.00
Tender For piped water supply scheme for on risk & cost piped water supply scheme for village- koti(imlidand,khaspara,korwapara) koti(panditpara) koti (daridih, pateratola, purankoti) block- wadrafnagar district – balrampur(c.g.)construction, testing and commissioning of r.c.c. elevated service reservoir of 00 kl capacities – 00 no. & staging 12 mtr& staging and steel structure 09 m height & 10 kl (5000l x 2no.)- 00 no.} pe tank & elevated service reservoirs of rcc staging and hdpe slim tank of capacity 5000 ltr of 00 no. 9 mtr staging (with switch room of size 1.8mx1.8mx3m) and 10000 ltr of 00 no. 12 mtr staging.including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber.providing, laying, jointing, interconnection, testing and commissioning of rising main upvc class 10 kg/sqcm 90 mm dia 00 m & hdpe 75mm dia 00 m & 63 mm dia 840 m., distribution upvc class 6kg/sqcm 90mm dia. 00 m., 110 mm dia. 00 m., 140 mm dia. 00 m. 160 mm dia. 00 m.& distribution hdpe class 6kg/sqcm 63 mm dia. 550 m., 75 mm dia. 1000 m.with suitable joints gi pipe, valve, specials and all fittings including all allied civil works, supplying & installation of energy taging n five star bee rating isi marked required capacity single phase / three phase, 50 hz, 220v,, deep well submersible pump stainless steel body, suitable for 4”/6” tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,ss/nylonwireropeandconnection cable including verification of tubewell yield& electric connection from cspdcl, construction of brick masonry switch room, construction of boundary wall around the over head tank, installation of electro chlorinator , construction of chlorinator room of providing functional household tap connection (f.h.t.c. 0 ) in individual households and government instiution etc. complete with trial run of 03 months after that o&m of 06 months under village-koti(imlidand,khaspara,korwapara)koti(panditpara) koti(daridih,pateratola,purankoti) block- wadrafnagar district – balrampur(c.g.)
Tender For piped water supply scheme for on risk & cost piped water supply scheme for village- darridih ( uraopara, purvtola ,khaspara ) block- balrampur district – balrampur(c.g.)construction, testing and commissioning of r.c.c. elevated service reservoir of 00 kl capacities – 00 no. & staging 12 mtr& staging and steel structure 09 m height & 10 kl (5000l x 2no.)- 00 no.} pe tank & elevated service reservoirs of rcc staging and hdpe slim tank of capacity 5000 ltr of 00 no. 9 mtr staging (with switch room of size 1.8mx1.8mx3m) and 10000 ltr of 00 no. 12 mtr staging.including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber.providing, laying, jointing, interconnection, testing and commissioning of rising main upvc class 10 kg/sqcm 90 mm dia 00 m & hdpe 75mm dia 00 m & 63 mm dia 00 m., distribution upvc class 6kg/sqcm 90mm dia. 00 m., 110 mm dia. 00 m., 140 mm dia. 00 m. 160 mm dia. 00 m.& distribution hdpe class 6kg/sqcm 63 mm dia. 1300 m., 75 mm dia. 127 m.with suitable joints gi pipe, valve, specials and all fittings including all allied civil works, supplying & installation of energy taging n five star bee rating isi marked required capacity single phase / three phase, 50 hz, 220v,, deep well submersible pump stainless steel body, suitable for 4”/6” tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,ss/nylonwireropeandconnection cable including verification of tubewell yield& electric connection from cspdcl, construction of brick masonry switch room, construction of boundary wall around the over head tank, installation of electro chlorinator , construction of chlorinator room of providing functional household tap connection (f.h.t.c. 46 ) in individual households and government instiution etc. complete with trial run of 03 months after that o&m of 06 months under village- darridih ( uraopara, purvtola ,khaspara ) block- balrampur district – balrampur(c.g.)
Tender For tender for supply of fully automatic horizontal high pressure, high volume sterilizer, h25 field test kit (water testing) 1 test, supply of x-ray protection lead sheet of required thickness (minimum 2 mm or as per aerb norms), for only existing door size as required. door size with frame: approx. 7 feet (h) x 4 feet (w) with installation, ishihara colour vision chart test book original japan make latest edition with book 38 plates, wooden physiotherapy couch-specification attached
Tender For maintenance and payment of electrical consumption charges of street lighting on pwd north west roads under nwed (sh supply, installation, testing and commissioning of storm water pumps autostart management system with online monitoring at haiderpur drain and wazirpur drain
Tender For supply delivery and fixing of motor and accessories at ward-1 selliyampalayam oht in narasingapuram municipality - supply and delivery of kirloskar make 15hp/11kw/2900rpm three phase/415v/50hz/ac/tefc horizontal centrifugal monoblock pump impeller-mechanical seal (head-20mtr,flow rate-2154lpm) size:100x100mm (local quotation) 15hp horizontal centrifugal monoblock pump, labour charges for erection of horizontal shaft, centrifugal pumpset (coupled/monoblock) in bore well/open well including fixing of suction pipe and foot valve upto a maximum depth of 7 metres and delivery pipes to the required length with valves,pressure gauges upto the exterior wall of pump room and erection of panel board consisting of tpic switches starter, voltmeter, ammeter, capacitor single phasing preventor and laying and jointing the cables and twinearthing as per ie rules including providing bed blocks etc., complete and operating the pumps and trial run for 10 days including signing of completion of reports as required by eb authorities., three phase panel board star- delta with two level guard and auto start supply and delivery of star-delta starter confirming to is 13947, iec60947-1 and as amended thereafter with suitable kw rating for operation in ac/ three phase/50hz (+/- 5%) and 415v (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., ct operated ammeter (65 mm dia) with suppressed scale,voltmeter (65mm dia),voltmeter selector switch,miniature circuit breaker, thermal overload relay, air break contactors suitable for next standard higher kw rating, single phasing preventor, dry running preventor and on/off push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capa citor is to be taken separately). three phase panel board for 15hp, supply,delivery and fixing of the following materials are listed below etc..,as directed by the departmental ofiicers.for service4 core 16sq.mm pvc copper ug cable, for motor3 core 6sq.mm pvc insulated and sheathed flat type copper cable, 150mm di pipe, 100mm gi pipe , 100mm gi flange set, rubber sheet for flange set, ms bolt and nut20mm dia and above x 90mm to120mm length fully threaded bolts andwith nuts 2 nos. , manhole cover 60 x 60cm (heavy duty) with frame, supply, erection, testing and commissioning of cast iron body and bronze internal non-rising spindle sluice valve of sizes at required places to control the flow of water including necessary ms flange of table e , gaskets, bolts & nuts including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the departmental officers. 150mm sluice valve, 100amps 4pole mcb, 100amps porcelain fuse unit (500v), 32mm pipe
Tender For repair/maint of air cooled ac plants, chiller, condenser pump, hot water boiler, ahu, water colled ac plants, motor, hwg and ahu alongwith connected items at akash complex/tech area at dappar under age(i) dappar - material and labour for servicing / cleaning of air cooled ac plants of 50 tr capacity, chiller unit, cleaning and washing of cooling coil with fins using a chemical c-shine (alkaline coil cleaner and brightener) and testing the unit (once in a three months) complete all as specified and as directed by engineer-in-charge. location :- akash air cooled ac plants(once in a three months), material and labour for descaling of complete condenser units for central/ package type ac plants of condenser unit of water cooled ac plantac plant upt to 40 tr capacities by means of adding descaling chemical solution (hcl) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and refixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. to entire satisfaction of engineer-in-charge complete all as specified and as directed by engineer-in-charge. location :- old, 3ac igloo ac plant and new ac plant (once in a three months), material and labour for cleaning of cooling tower existing size, water basin and makeup tank with the help of chemical and nylon brush, removing and refixing of pvc finches after washing, cleaning of condenser pipe line ( inlet and outlet) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by engineer in charge and inside painting of water tank of cooling tower using water proof black japan paint one coat including changing of unserviceable pvc guard, water distibutor, pvc pipe, and all connected minor items of up to 100 tr capacity of the ac plants at different locations complete all as specified and as directed. location :- old and new ac plant, material and labour for servicing of cooling coils and air filters of ahus intalled at air conditioning plant by removing air filters and fixing after cleaning with air blower and water and cleaning agent , cleaning of cooling coilwith wire brush and air blower and water spray pump after spraying scale gun or equivalant chemical suitable for aluminium fins and straighting the fins of cooling coil by using suitable brush for any capacity of ahu complete all as specified and as directed by engineer-in-charge. locaton :- new ac plant, old ac plant , 3 ac igloo ac and akash ac plants akash, material and labour for servicing / cleaning and testing of electrically operated pan type humidifier capacity 9 kw alongwith all necessary items fitting and all suitable / all necessary electrical wiring from electrical panle to humidifier complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in cold water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in hot water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing , cleaning , and greasing , chiller , hwg pumps , ahu and ct motors alongwith all necessary minor items/ fitting i.e bearing , star coupling , screws , nuts and bolts etc complete all as specified and as directed by engineer-in-charge. location :- new ac plant , old ac plant and air coole
Tender For repair / maint of split acs 2/1.5 ton , windows acs 2 / 1.5 ton , voltage stablizers and connected items installed at command hospital (wc) and other various location in aor of age e/m ch - servicing of split type ac of capacity 2/ 1.5 tr after disconnecting all incoming and outgoing electric connection, water drain pipe line connection etc. and wash with approved chemical mixed water with the pressure pump, after servicing cleaned all the disturbed area and reassembling the water/electric connection and testing for entire satisfaction of engr-in-charge., all as per item no. 1 here-in-above but window type ac 2/1.5 tr capacity., supplying and charging of refrigerant gas r-22 only after vacuuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by engr-in-charge for room split/window type ac of capacity 2/1.5 tr., all as per item no: 3 above but gas r-32, all as per item no: 3 above but gas r-410a., all as per item no: 3 above but gas r-134a., taking out defective capacitor of capacity 50+6 mfd after disconnecting all incoming and outgoing electric connection including supply & fix new capacitor on same place and testing complete all as specified and as directed by engr-in-charge, all as per item no:7 here in above but of capacity 45+4 mfd ., all as per item no:7 here in above but of capacity 45 mfd ., all as per item no: 7 here in above but of capacity 6 mfd ., all as per item no: 7 here in above but of capacity 4 mfd ., supply & fixing as in replacement copper pipe 1/2" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 1/4" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 5/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 3/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply and fixing of insulation foam for copper pipe of size 1/2" after removing old one., supply and fixing of insulation foam for copper pipe of size 1/4" after removing old one., supply and fixing of insulation foam for copper pipe of size 5/8" after removing old one., supply and fixing of insulation foam for copper pipe of size 3/8" after removing old one., supply and fixing as in replacement of pvc flexible pipe 15 mm dia including any fittings as required complete inclusive of any type of leakage testing., all as per item no: 20 above but pipe of 20 mm dia., supply and fixing as in replacement of pvc water drain pipe 25 mm dia complete inclusive all fittings and any type of leakage testing., material and labour for sub main wiring with 2 x 2.5 sqmm +1 x 2.5 sqmm single core flame retardant pvc insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade frlsh pvc concealed conduit isi marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps guittes etc for earth dbs and boxes with proper thimbles all as directed by engr-in-charge. note :02 run of 2.5 sqmm , 01 run of 2.5 sqmm cable and 01 run of conduit shall be measured as one unit and paid accordingly., all as per item no: 23 here in above but of size 2x 4 sqmm +1x 4 sqmm., m&l cutting chases, pinning in stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cutting exc. 10 cm girth., supply and fix as in replacement of rigid non-metallic pvc conduit of size 20