Web Analytics Made Easy - StatCounter

Telecommunications Machine Tenders

Get complete information related to latest Telecommunications Machine Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Telecommunications Machine Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Telecommunications Machine Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45543528 Due date: 23 Jun, 202623 Jun, 2026 NA
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - fabrication of required furniture for science communication centre at nii, new delhi

CTN :45263256 Due date: 25 Jun, 202625 Jun, 2026 NA
Tender For corrigendum : supply and installation of telecom and scada equipments for extending data connectivity to upcoming cgd hookups and lmc connectivity in southern region on annual rate contract basis - supply items under arc for telecom system, supply of mpls tp equipment, supply of ip/mpls type switch, supply of converter, ac-dc (230 v ac to 48 v dc), ac-dc (230 v ac to 24 v dc), dc-dc (48 v dc to 24 v dc), dc-dc (24 v dc to 48 v dc), supply of battery charger with battery backup, supply of porta cabin, supply of lct, supply of equipment racks, supply of solar panel with battery back up 300 w, supply of solar panel with battery back up 200 w, supply of solar panel with battery back up 50 w, supply of explosion proof telephone, supply of weatherproof telephone, supply of acoustic half hood booth, supply of multi-paired armoured cable (10 pair), supply of 6 twisted pair, 1.5 sq. mm ( 12 core ), individual pair andoverall aluminium mylar tape shielded with drain wire, supply of 6 twisted pair, 0.50 sq. mm ( 12 core ) individual pair and overall aluminium mylar tape shielded with drain wire, supply of telemetry interface cabinet (tic), supply of analog phones, supply of fxo gateway, supply of fxs gateway, supply of ethernet switch, supply of rtu, supply of mini rtu, supply of ftc, supply of joint closures, supply of ip camera, supply of spares for telecom, supply of spares for rtu, supply of ethernet to serial converter, supply of optical to serial convereter, supply of rs 232 to rs 422/rs485 converter, supply of optical to ethernet converter, supply of out door equipment panel, supply of field mounted enclosure conforming ip-66, supply of gprs modem, supply of atex switch 8 port, supply of 24f ofc cable, supply of rtu management licenses for makes like husky, schneider, etc, telecom system (works), installation of mpls/tp equipment, integration of mpls/tp equipment with existing nms, installation and commissioning of solar system, installation of porta cabin, laying and termination of multi-paired armoured cable (10 pair), installation and configuration of converter/switch and interfacing of same with flow computer and integration with scada system, installation of tic panel, design, engineering and submission of documents, testing of ofc and submission of reports, earthing works, installation testing & commissioning of instrumentation cable, installation commissioning and integration of rtus in existing scada server, installation commissioning and integration of mini rtus in existing scada server, installation and integration of ip cameras in existing server for each cameras, installation of gprs modems if supplied as free issue, extending of leased lines for 1000 km distance including modems (one ethernet interface & one e1 interface for lan) at both ends, rectification of ofc including supply of joint pit with identification of fault and testing of of cable, installation of outdoor panel, transportation charges for free issue material (per km rate to be quoted), laying of ofc through hdd method, laying of ofc through direct trench method, point to point radio communication (2.4/5.8 ghz licence free ism band), laying of ofc cable ( if ofc supplied as free issue by gail), blowing of ofc in duct, manday charges [post-installation manday charges for rtu/telecom works on an on-call basis, including troubleshooting, system calibration, software updates, configuration adjustments, and performance optimization. ], total amount excluding gst, gst (cgst&sgst/utgst or igst) in percentage (%) on net total amount

CTN :45535219 Due date: 20 Jun, 202620 Jun, 2026 NA
Tender For purchase of ece department lab electronics equipments - equipments for ece, dual output regulated dc variable power supplyinput voltage : 230v/50hz acoutput voltage :(0-30)v dcoutput current :(0-2)a dcprotection circuit : over voltage, over current, and short-circuit protectionhigh efficiency : greater than 85%low ripple and noise : less than 50 mvdigital display, function (signal) generatorspecs:frequency range : 0.1hz to 5mhzdisplay :4 to 6 digit led displayoutput waveforms : sine, triangle, square, pulse, rampamplitude :0-20 vpprise time :100 nsdistortion : 1% within specified frequency rangepower supply : 230v ac 10% , 50-60 hzoutput amplifier protection : short circuit and 15voverload protectiondc offset: 0 to 10 v adjustableattenuation: 0 to -60 db, decade resistance box range : 1 to 1m rotary switch selection with 6 dialssteps : 1 , 10 , 100 , 1k , 10 k , 1m accuracy : 1%, decade capacitance box range : 100 pf to 100 frotary switch selection with 6 dialsmaximum voltage : 350vaccuracy : 1%, decade inductance box range : 10 h to 10 hrotary switch selection with 6 dialslow-loss inductorsaccuracy : 1%, sim reader trainer kitpower supply :operates on 230v ac 10%, 50hz mains supplybuilt-in regulated smps power supplyoperating dc supply : 5v/12v with overload and short-circuit protectionsim card interface :supports gsm sim cards compatible with 2g / 3g / 4g / 5g networkssim card read/write interfacesupports sim card initialization, authentication and communication functionscompatible with standard 6-pin / 8-pin sim card socketscommunication interface :usb 2.0 interface for pc communicationrs-232 serial communication interfaceuart communication facility for embedded system interfacingsim operating parameters :selectable sim clock frequencies3.579 mhz7.159 mhz14.318 mhzsim supply voltage selection facilitysim reset and activation controlsupported protocols and standards :gsm etsi 07.07 and etsi 07.05 at command supportiso/iec 7816 smart card communication supportsim communication command monitoring facilityhardware features :on-board sim card socketled indication for :power statussim detectionreset activityuser manualutility software cd / downloadable software packagedata transmission/receptionbuilt-in keypad for standalone operation.lcd display module (128 64) for menu and status display.on-board microcontroller-based control section.software support:at command execution and monitoring software.sim manager utility software.data logging and communication terminal utility.pc-based gui software for sim data communication experiments.trainer features:fault simulation facility for troubleshooting experiments.simulation of faults such as:sim not detectedclock failurevcc failurereset failuremultiple on-board test points for signal observation.test points for:sim rstsim_clksim iovccuart tx/rxsuitable for cro/dso signal monitoring.glass epoxy pcb with educational block diagram layout.compact tabletop enclosed cabinet design.construction:front panel with printed block diagram.banana test points and patching facility.standard accessories:gsm sim trainer unit.usb communication cable.rs-232 communication cable.power cord., microwave test bench with reflex klystron oscillatormicrowave source :relex klystron tube with klystron mountoperating frequency in x-band (8.2ghz to 12.4ghz)electronic tuning through repeller voltage controlsuitable for cw microwave generationklystron powersupply:regulated klystron power supply unitbuilt-in modulation facilityoverload and short circuit protectionoperates on 230v ac 10%, 50hz mains supplywaveguide components:isolator variable attenuatorfrequency meterslotted line section with tunable probecrystal detector mountmatched loadmovable short / terminationwaveguide stands and accessoriesmeasurement unit:solid state vswr meter with high sensitivityswr measurement facilitysuitable for detector output monitoringtechnical specification :frequency range : 8.2 ghz to 12.4 ghzwaveguide types : wr-90detector type : crys

CTN :45516001 Due date: 20 Jun, 202620 Jun, 2026 NA
Tender For purchase of ece lab electronics equipments - equipments for ece, dual output regulated dc variable power supplyinput voltage : 230v/50hz acoutput voltage :(0-30)v dcoutput current :(0-2)a dcprotection circuit : over voltage, over current, and short-circuit protectionhigh efficiency : greater than 85%low ripple and noise : less than 50 mvdigital display, function (signal) generatorspecs:frequency range : 0.1hz to 5mhzdisplay :4 to 6 digit led displayoutput waveforms : sine, triangle, square, pulse, rampamplitude :0-20 vpprise time :100 nsdistortion : 1% within specified frequency rangepower supply : 230v ac 10% , 50-60 hzoutput amplifier protection : short circuit and 15voverload protectiondc offset: 0 to 10 v adjustableattenuation: 0 to -60 db, decade resistance box range : 1 to 1m rotary switch selection with 6 dialssteps : 1 , 10 , 100 , 1k , 10 k , 1m accuracy : 1%, decade capacitance box range : 100 pf to 100 frotary switch selection with 6 dialsmaximum voltage : 350vaccuracy : 1%, decade inductance box range : 10 h to 10 hrotary switch selection with 6 dialslow-loss inductorsaccuracy : 1%, sim reader trainer kitpower supply :operates on 230v ac 10%, 50hz mains supplybuilt-in regulated smps power supplyoperating dc supply : 5v/12v with overload and short-circuit protectionsim card interface :supports gsm sim cards compatible with 2g / 3g / 4g / 5g networkssim card read/write interfacesupports sim card initialization, authentication and communication functionscompatible with standard 6-pin / 8-pin sim card socketscommunication interface :usb 2.0 interface for pc communicationrs-232 serial communication interfaceuart communication facility for embedded system interfacingsim operating parameters :selectable sim clock frequencies3.579 mhz7.159 mhz14.318 mhzsim supply voltage selection facilitysim reset and activation controlsupported protocols and standards :gsm etsi 07.07 and etsi 07.05 at command supportiso/iec 7816 smart card communication supportsim communication command monitoring facilityhardware features :on-board sim card socketled indication for :power statussim detectionreset activityuser manualutility software cd / downloadable software packagedata transmission/receptionbuilt-in keypad for standalone operation.lcd display module (128 64) for menu and status display.on-board microcontroller-based control section.software support:at command execution and monitoring software.sim manager utility software.data logging and communication terminal utility.pc-based gui software for sim data communication experiments.trainer features:fault simulation facility for troubleshooting experiments.simulation of faults such as:sim not detectedclock failurevcc failurereset failuremultiple on-board test points for signal observation.test points for:sim rstsim_clksim iovccuart tx/rxsuitable for cro/dso signal monitoring.glass epoxy pcb with educational block diagram layout.compact tabletop enclosed cabinet design.construction:front panel with printed block diagram.banana test points and patching facility.standard accessories:gsm sim trainer unit.usb communication cable.rs-232 communication cable.power cord., microwave test bench with reflex klystron oscillatormicrowave source :relex klystron tube with klystron mountoperating frequency in x-band (8.2ghz to 12.4ghz)electronic tuning through repeller voltage controlsuitable for cw microwave generationklystron powersupply:regulated klystron power supply unitbuilt-in modulation facilityoverload and short circuit protectionoperates on 230v ac 10%, 50hz mains supplywaveguide components:isolator variable attenuatorfrequency meterslotted line section with tunable probecrystal detector mountmatched loadmovable short / terminationwaveguide stands and accessoriesmeasurement unit:solid state vswr meter with high sensitivityswr measurement facilitysuitable for detector output monitoringtechnical specification :frequency range : 8.2 ghz to 12.4 ghzwaveguide types : wr-90detector type : crystal detecto

CTN :45519346 Due date: 24 Jun, 202624 Jun, 2026 NA
Tender For supply of lab equipments for eee department - list of equipments, dso bandwidth: 50 - 100 mhz. sampling rate: 1gs/s. channels: 2 (minimum) power supply: 100v 240v ac, 50-60 hz automatic measurement: vpp, vavg,rms, frequency, period, vmax, vmin, rise time, fall time, + width, - width, +duty, - duty etc., horizontal scale: 5 ns/div 50 s/div or equivalent vertical resolution: 8 bits (2 channels simultaneously) vertical sensitivity: 1 mv/div 10 v/div (at input) waveform math: +, -, x , , invert, fft etc., waveform storage: 16 waveforms or equivalent communication interface: usb host, usb interface. 7-inch color display or equivalent input impedance - 1 m 2%, // 20 pf 2 passive probes (1x/10x)

CTN :45384472 Due date: 17 Jun, 202617 Jun, 2026 NA
Tender For corrigendum : purchase of equipments for dmt department lab - purchase of equipments for dmt department lab, fanuc cnc simulation trainer kit system type: standalone cnc simulation trainer with integrated hardware panel functionality: switchable milling (3-axis) and turning (2-axis) simulation cnc control: original fanuc control system or officially licensed equivalent software: manual guide i (licensed version) for conversational programming and 3d simulation programming: supports g code (iso standard) and conversational programming storage: minimum 512 kb program storage with at least 400 programs tool offsets: minimum 32 pairs coordinate system: g52 g59 with minimum 48 additional work offsets (milling) display: minimum 10 color lcd input: full qwerty keyboard connectivity: usb, ethernet interfaces: rs232 / i/o link power supply: 100 240 v ac, 50 60 hz power consumption: 100 w construction: industrial grade trainer unit , robotic arm controllerdegrees of freedom: 6 dof payload: minimum 250 g at full reach reach: minimum 350 mm repeatability: 0.2 mm or better controller: industrial-grade controller (arm cortex-m4 or higher / equivalent architecture) programming: supports gui based and programming (python / c++ / equivalent) vision system: integrated camera with ai-based object detection capability communication: usb and serial communication software: licensed software compatible with windows os end effectors: minimum 3 (gripper, suction cup, pen holder) safety: emergency stop, limit protection power supply: 100 240 v ac, 50 60 hz, optical digital microscopemagnification: 40x to 400x digital camera: minimum 5 mp resolution display: pc/monitor via usb/hdmi or built-in display illumination: adjustable led illumination focus: coarse and fine focusing mechanism optics: coated lenses with wide field view stage: mechanical stage with slide holder software: image capture, measurement, and analysis software included connectivity: usb / hdmi /ethernet power supply: 110 240 v ac, 50 hz, portable surface roughness tester parameters: ra, rz, rq, rt measuring range: ra: 0.005 16 m rz: 0.02 200 m resolution: 0.01 m accuracy: 5% or better stylus: diamond tip ( 5 m radius) cut-off lengths: 0.25 mm, 0.8 mm, 2.5 mm display: digital lcd output: usb interface for pc connection standards: iso 4287 / din / ansi compliant power: rechargeable battery

Central Government/Public Sector

CTN :45493462 Due date: 12 Jun, 202612 Jun, 2026 NA
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - marine unit; l 301 cme water jet from remote control lever mcr bridge is not responding in ahead astern position suspect communication between rcs and pcmu modules in lo..

Central Government/Public Sector

CTN :45436807 Due date: 17 Jun, 202617 Jun, 2026 NA
Tender For supply, installation and commissioning of control office equipments (coe) for data retrieval and analytics system for 3 phase electric locomotives as per part 3 of clw spec.no. clw/c-d&d/es/3/0554 issued in april 2024 or latest and scope of work as per annexure- 1.sads comprising large led , daws comprise of high end , remote office communication and asset management , rack 19'' mass rack , power conditioning equipment , smart phone with sads apps with 5g connectivity , modular furniture , transportation, fitment, commissioning of all (sads, daws, furniture, wiring between all these items) including all materials required to connect i.e. electrical wiring, lan wiring, hdmi cables, switches, sockets etc

Central Government/Public Sector

CTN :45137545 Due date: 09 Jun, 202609 Jun, 2026 NA
Tender For corrigendum : providing of customized amc/cmc for pre-owned products - m19515 annual service and maintenance contract of all equipments and accessories related to plc system plc dcs and scada vfds simocode and communication network of paste plant at mcp; as per scope of work..

CTN :45374624 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For supply installation of plcc system associated communication and interface equipments etc at tapovan vishnugad hep end and for the data transmission to ptcul on deposited work basis
 Loading, Please wait...

Connect us via What's Up