Get complete information related to latest Telephone Pole Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Telephone Pole Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Telephone Pole Tenders.
Tender For supply, termination installation, testing and commissioning of ventilation system on roof of paint shop of lower parel workshop along with complete installation, frame work of suitable size with ms 50mmx 50 mmx 5mm, cabling, cable try work, wiring and protection system with 4 pole 20a mcb for each and mcb board along with 2.5 sqmm cable 4 core and 10 sqmm cable from panel to distribution board for main supply and power full exhaust system of length and height minimum 1 meter with width minimum 400 mm, diameter blades 900 mm, blades rotational speed -620 r/min or more. air flow 30,000 m?/h, noise level shall be less than 70 db, power shall be minimum 750 watt with the flap system and motor starter of 1 hp or as per suitable and confirming to s/iec 60947-4-1 or latest. all electrical works shall be carried out in accordance with the provision of indian electricity act 2003 and indian electricity rules 1956 amended to date and all the safety codes and procedures outlined in the safety codes shall be complied with general and safety requirement shall be governed by is 13947 (pt i) 1993 and is:8623/1993, amended to date. termination of all cables shall be done with bimetallic terminal connector suitable for 2.5 dia aluminium tubular busbar for 20a copper palm copper cu etp cw 0041a and aluminium barrel aluminium al 99.5 cable connector temperature resilience, corrosion resistance size: 2.5 sqmm confirming to is: 5561-1970 with maximum temperature rise of 90 degree celsius. material shall be confirmed to designation a6 of is: 617-1959. breaking resistance for barrel 85 n/m sq m and for palm 225 n/m sq m with stretching a5% for barrel must be for palm 2.5. type test certificate from nabl or any other govt agency lab report shall be attached along with the offer without which offer will be rejected. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : for the work of a.b cable reconductoring and additional circuit, replacement of damage line and pole, pvc wrapping on pole, stay set and stay insulator and battery charger sanctioned under business plan 2026-27 in areas under electricity urban distri
Tender For corrigendum : replacement of damaged broken pcc and st pole, repairing and maintenance of line at area of sub-division-milkipur under jurisdiction of electricity distribution division- milkipur, ayodhya (running work)
Tender For corrigendum : replacement of damaged broken pcc and st pole, repairing and maintenance of line at area of sub-division-kumarganj under jurisdiction of electricity distribution division- milkipur, ayodhya (running work)
Tender For bid to ras corrigendum : providing of custom bid for services - construction of 11 kv/lt lines, establishment of double-pole lt substations, installation of metering systems, and the shifting of various ht/lt electricity lines in the area of edd, lalitpur under deposit scheme
Tender For corrigendum : work mention in boq - long span inserting pole of different places with construction of l&t jarjar line under the jurisdiction of electricity distribution division- maharajganj, raebareli. (bp 2026-27)
Tender For corrigendum : 15/edc(blp)/2026-27 - loading, unloading and safe cartage of the following materials from electricity store centre, balrampur to the work site/dump site (distance up to 50 km), st poles (11 mtr long), pcc poles (8.5 mtr long), acsr weasel conductor, lt abc 3x120+1x95+1x16sq.mm., 100 kva t/f, other line materials, erection of single st poles (11 mtr long) for 11 kv/l.t. line alongwith fitting of all accessories on pole including dragging of pole from dump site to pit site, erection of single pcc poles (8.5 mtr long) for 11 kv/l.t. line alongwith fitting of all accessories on pole including dragging of pole from dump site to pit site, erection of sectional double pole sectional pcc pole (8.5 mtr long pcc pole) alongwith fitting of all accessories on pole including dragging of pole from dump site to pit site., earthing of pole as per uppcl/resspo norms.., erection and grouting of stay sets alongwith complete fittings. cement, sand & brick ballast provided by the contractor at his own cost., grouting of poles with 1:4:8 cc ratio of cement, sand & brick ballast, backfilling of pits with mud completely.all required materials provided by the contractor at his own cost., laying, stringing, sagging & binding of conductors of 11 kv in 3 phase, 3 wire line with jumpering (where as required), laying, stringing & sagging of 3x120+1x95+1x16sq.mm. abc cable up to proper sag for the following size cable, construction of 11/0.4 kv s/s for 100 kva t/f with mounting and fitting of t/f on plinth/double pole with proper fitting of all acessories and connecting with all circuit including earthing of t/f fitting with all accessories., earthing of distribution t/fs for body & neutral upto water level with gi pipe of 1.5" dia. including gi strip size 35x6 mm. (all material will be supplied by contractor)., decentralized materials:-providing and fixing of following materials as per sanctioned estimate/package as per resspo u.p.p.c.l. drawing/ norms.(where is required)., suspension clamp with i hook, i hook, suspension clamp with i hook, i hook, lt fuse set., lt pvc cable al 1x120sq.mm., lt pvc cable al 1x400sq.mm., lug sutable for 250 kva, suspension clamp with i hook, i hook, lt fuse set., lt pvc cable al 1x120sq.mm., lt pvc cable al 1x400sq.mm., lug sutable for 250 kva
Tender For construction of 11kv line shaheed smarak feeder double circuit under ground with trenchless (hdd) with stp pole riser under the juridiction of electricity distribution division raebareli. (under bp 2026-27 scheme)