Get complete information related to latest Temperature Relay Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Temperature Relay Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Temperature Relay Tenders.
Tender For supply of lt miscellaneous items for lt switchgear lt system for the year 2024-25 unit 5 and 6 csctpp chhabra - air flow sensor sl0101, control supply -230v ac, with 1 no +1nc contact, make-ifm or equivalent, dynamic braking resistor 13 ohms/ 9600w, 10% ed, 10 sec. max, ambient 50 degree,make-iresco/equi or equivalent, fan: axial, dia: 250, 230vac, 50hz, 115w, air flow:1610 m3/h (specification attached at annexure-i), fan: axial, dia: 450, 415 vac, 50hz,480 w, air flow:4530 m3/h,speed-1360 rpm,(specification attached at annexure-ii), fan axial 08" ball bring 230v ac 1p-50hz (as per annexure-iii ), relay assly : 4 relay, 2 c/o, 5a/24v dc, with led indication, iron core reactor 3 phase, 0.359mh/45a, 3 ph iron core, 117 uh/240a, make: rishab/ transformer/epi/equi or equivalent, 3 ph iron core, 67 uh/240a, make:rishab/ transformer/epi/equi or equivalent, 3 phase line choke ,in-21 amp,inductance-4.2mh,class-f,freq-50hz,voltage-415v, 3 phase line choke ,in-21 amp,impedance-3%,class-f,freq-50hz,voltage-415v, ct: metering 250/5a, 15va, class 1, ct dim.: 180{w}, 100{d}, 70{h}, window size:20x35mm, front terminals, resin, cast, insulation class:e, type 2, colour:yellow, resin cast insulaed c.t 400/5a,class-1,va-10, resin cast insulaed c.t 400/1a,class-1,va-10, thermal overload relay range 95-120 a, 125hp three phase submersible pump star delta starter with 3-position selector switch (with auto switch), single phase preventer, current overload protection with short circuit protection., aluminium ring type terminal lugs conforming to is-8337/is-5082 ,iec-61238,for voltage rating 1.1 kv, 6 sq.mm, 10 sq.mm, 16 sq.mm, 25 sq.mm, 35 sq.mm, 50 sq.mm, 70 sq.mm, 95 sq.mm, 120 sq.mm, 150 sq.mm, 185 sq.mm, aluminium pin type terminal lugs conforming to is-8337/is-5082 ,iec-61238,for voltage rating 1.1 kv, 10 sq.mm, 16 sq.mm, 35 sq.mm, copper ring type terminal lugs conforming to is-8337/is-5082 ,iec-61238,for voltage rating 1.1 kv, 1.5 sq.mm, 2.5 sq.mm, 6 sq.mm, 10 sq.mm, 16 sq.mm, 25 sq.mm, power terminals mounting on din conforming iec 60947-7-1,voltage rating-1 kv,safe for fingers., current rating-140 a, 35 sq.mm,3 nm, current rating-192 a, 70 sq.mm,6 nm, current rating-232 a, 95 sq.mm,6 nm, copper pin type terminal lugs conforming to is-8337/is-5082 ,iec-61238,for voltage rating 1.1 kv, 1.5 sq.mm, 1.5 sq.mm(hollow type), 2.5 sq.mm, 2.5 sq.mm(hollow type), 6 sq.mm, 10 sq.mm, 16 sq.mm, 25 sq.mm, copper u type terminal lugs conforming to is-8337/is-5082 ,iec-61238,for voltage rating 1.1 kv, 1.5 sq.mm, 2.5 sq.mm, 6 sq.mm, terminals blocks (melamine housing) khaki color, 4 sq. mm, 32 amp., 600v, 10-20awg, screw type, din mounting, 6 sq. mm, 41 amp., 800v, 08-20awg, screw type, din mounting, 6-35 sq. mm, 125 amp., 750v, screw type, din mounting, 1.5-4sq. mm, 32 amp., 800v, 08-20awg, stud type, bolt connection, clip on din mounting, 35-50sq. mm, 125 amp., 1000v, clip on din mounting, wago make grey colour screwless , spring clamp, polyamide terminals for interpanel wiring , terminal:769-251, female plug:769-102 with add-on, modular timing relay,5a,2co,0.1s 100h,on-delay,230v ac, voltage-transducer, suitable for 24v dc power supply,i/p:0-500v ac,dual o/p(4-20ma), din rail mounted,, shunt resistor, 750a/60mv,0-60mv, shunt resistor, 175a/60mv,0-60mv, shunt resistor, 200a/60mv , 0-60mv, thermal overload relay,1.6a-2.5a, 3 pole, bi - metallic, 1 no + nc,, thermal overload relay,16a-25a, 3 pole, bi - metallic, 1 no + nc,, ac axial fan230 vac,50/60 hz 6"172x150x51 mm(model no rec-21725b2w) rexnord make or equivalent for 1:1 replacement, ac axial fan230 vac,50/60 hz 4"120x120x38 mm(model no rec-22038 a2t) rexnord make or equivalent for 1:1 replacement, transformer protection relay,i/p-4 nos of rtd sensors(pt-100),3 no of set points,0-300 temperature indication range,o/p-four relay contacts(01 c/o contacts),one analog 4-20 ma output contacts ,aux supply -90-270 v ac/dc,pecon make ,model no-tr-7570 or equivalent for 1:1 replacement, add-on auxiliary contact blo
Tender For supply of providing and fixing of lightning conductor finial. , jointing copper or g.i. tape with another copper or g i tape , providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall , providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess , repairing rewinding of 1 hp capacity centrifugal pump , repairing rewinding of 2 hp capacity centrifugal pump , repairing rewinding of 3 hp capacity centrifugal pump set , repairin rewinding of 5 hp capacity centrifugal pump set , repairing rewinding of 1.5 hp capacity submersible pumpset , repairing rewinding of 2 hp capacity submersible pumpset , repairing rewinding of 3 hp capacity submersible pumpset , repairing rewinding of 5 hp capacity submersible pumpset , sitc of submersible pumpset of 2 hp water filled , sitc of submersible pumpset of 4 hp water filled , lifting and lowing of submersible or borewell pump upto 5 hp alongwith gi pipe , lifting and lowing of submersible or borewell pump upto 5 hp alongwith hdpe pipe , repairing rewinding of 2 hp sump pump set , repairing rewinding of 3 hp sump pump set , repairing rewinding of 5 hp sump pump , replacement of faulty foot valve of size 40 mm dia , replacement of faulty foot valve of size 50 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 20 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 40 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 50 mm dia , replacement of nrv with new nrv made up of brass of size 40 mm dia , replacement of nrv with new nrv made up of brass of size 50 mm dia , supplying and fixing 20 mm dia b class medium g.i pipe , supplying and fixing 40 mm dia b class medium g.i pipe , supplying and fixing 50 mm dia b class medium g.i pipe , supplying and fixing 20 mm dia heavy duty upvc pipe , supplying and fixing 40 mm dia heavy duty upvc pipe , supplying and fixing 50 mm dia heavy duty upvc pipe , replacement 3 pole power contactors type mnx 12 , replacement 3 pole power contactors type mnx22 , replacement of mounting add on aux. contact block suitable for 9 a to 30 a , replacement of thermal overload relay suitable for mnx contactor range from 0.2 a to 23 a , supplying of 3 x 2.5 sq. mm aluminum conductor cable of 1.1kv grade , supplying of 4 x 16 sq. mm aluminum conductor cable of 1.1kv grade , supplying of 3.5 x 35 sq. mm aluminum conductor cable of 1.1kv grade , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size upto 35 sq.mm on cable tray , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm on cable tray , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm on cable tray , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size //bid details 3 / 138 upto 35 sq. mm on wall surface , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm on wall surface , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm on wall surface , s and m end termination with brass compression gland and aluminium lugs for 2 x 6 sq.mm al cable. , s and
Tender For supply of providing and fixing of lightning conductor finial. , jointing copper or g.i. tape with another copper or g i tape , providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall , providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess , repairing rewinding of 1 hp capacity centrifugal pump , repairing rewinding of 2 hp capacity centrifugal pump , repairing rewinding of 3 hp capacity centrifugal pump set , repairin rewinding of 5 hp capacity centrifugal pump set , repairing rewinding of 1.5 hp capacity submersible pumpset , repairing rewinding of 2 hp capacity submersible pumpset , repairing rewinding of 3 hp capacity submersible pumpset , repairing rewinding of 5 hp capacity submersible pumpset , sitc of submersible pumpset of 2 hp water filled , sitc of submersible pumpset of 4 hp water filled , lifting and lowing of submersible or borewell pump upto 5 hp alongwith gi pipe , lifting and lowing of submersible or borewell pump upto 5 hp alongwith hdpe pipe , repairing rewinding of 2 hp sump pump set , repairing rewinding of 3 hp sump pump set , repairing rewinding of 5 hp sump pump , replacement of faulty foot valve of size 40 mm dia , replacement of faulty foot valve of size 50 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 20 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 40 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 50 mm dia , replacement of nrv with new nrv made up of brass of size 40 mm dia , replacement of nrv with new nrv made up of brass of size 50 mm dia , supplying and fixing 20 mm dia b class medium g.i pipe , supplying and fixing 40 mm dia b class medium g.i pipe , supplying and fixing 50 mm dia b class medium g.i pipe , supplying and fixing 20 mm dia heavy duty upvc pipe , supplying and fixing 40 mm dia heavy duty upvc pipe , supplying and fixing 50 mm dia heavy duty upvc pipe , replacement 3 pole power contactors type mnx 12 , replacement 3 pole power contactors type mnx22 , replacement of mounting add on aux. contact block suitable for 9 a to 30 a , replacement of thermal overload relay suitable for mnx contactor range from 0.2 a to 23 a , supplying of 3 x 2.5 sq. mm aluminum conductor cable of 1.1kv grade , supplying of 4 x 16 sq. mm aluminum conductor cable of 1.1kv grade , supplying of 3.5 x 35 sq. mm aluminum conductor cable of 1.1kv grade , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size upto 35 sq.mm on cable tray , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm on cable tray , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm on cable tray , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size //bid details 3 / 138 upto 35 sq. mm on wall surface , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm on wall surface , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm on wall surface , s and m end termination with brass compression gland and aluminium lugs for 2 x 6 sq.mm al cable. , s and