Tender For repair/maintenance of diesel generator set with central panel and other connected items at zone 5 and 1(a,b,c) zone 1, 3 (a and b), zone 2 and zone 4 under ge (s) tezpur - maint and servicing of dg set 320-400 kva conopy type with amf panel (if installed ), through authorise service agency of oem , including replacment of defective/wornout parts with new spares such as filters, gaskets, v belts, engine oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of pol tank and radiator etc complete all as specified and directed.note:- 1. spares required for above maint will be measured and paid separately under relevent items of schedule. 2. all breakdown calls should be attended., all as per item no-1 above but for dg set of capacity 180-250 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 125-160 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 40-100 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 10-35 kva complete all as specified and directed, supply only fuel filter for 300-400 kva dg set, complete all as specified and directed, supply only fuel filter for 125-250 kva dg set,complete all as specified and directed complete all as specified and directed, supply only fuel filter for 10-100 kva dg set,complete all as specified and directed, supply only lub oil filter for 300-400 kva dg set,complete all as specified and directed, supply only lub oil filter for 125-250 kva dg set,complete all as specified and directed, supply only lub oil filter for 10-100 kva dg set,complete all as specified and directed, supply only air cleaner filter ( inner and outer ) for 300-400 kva dg set, complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 125-250 kva dg set,complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 10-100 kva dg set,complete all as specified and directed, supply only bypass filter for 300-400 kva dg set, complete all as specified and directed, supply only bypass filter for 125-250 kva dg set,complete all as specified and directed, supply only bypass filter for 10-100 kva dg set,complete all as specified and directed, supply only v belt for 300-400 kva dg set, complete all as specified and directed, supply only v belt for 125-250 kva dg set, complete all as specified and directed, supply only v belt for 10-100 kva dg set, complete all as specified and directed, supply only coolant for radiators complete all as specified and directed., supply only engine oil multi grade 15w40 complete all as specified and directed., s & f in repair display control panel ( base card) for 10 to 100 kva dg set complete all as specified and directed ., s & f in repair display control panel (base card) for 125 to 250 kva dg set complete all as specified and directed., s & f in repair display control panel (base card) for 300 to 400 kva dg set complete all as specified and directed., s & f in repair fuel actuator with o ring for 300 to 400 kva dg set complete all as specified and directed., s & f in repair key switch for 10 to 400kva dg set complete all as specified and directed., s & f in repair coolant temperature sensor (coolent control safety) for 10 to 400kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 10 to 100 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 125 to 250 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 300 to 400kva dg set complete all as specified and directed., s & f in rep
Tender For procurement of cni spares for blue star chillers lcw2 at brbcl - si board,cdco-w040-01,bluestar, mcs control board,cdco-w039-01,bluestar, current transformer,elct-000001-00, smps,elcp-w011-01,bluestar, oil level switch,elot-t020-00,blue star, phase reversal unit,elsp-w001-00, magnum display,bluestar,mcs controller, exp vv seh-175,rcexv-she 175-00,bluestar, timer,3rp15761np30,bluestar, elct expansion valve,rcexv-000000 2-00, oil heater,3101-1052c,bluestar, motor protection dev,ach4405-81,bluestar, temperature sensor,mcs-t100-402, pressure sensor,spps-t004-00,blue star, pressure sensor,mcs-ti-200f-20,blue star, load solenoid valve,rcsl-evr25-00, coil,rcsc-0000001-00,blue star, solenoid valve,rcsl-10001-00,blue star, solenoid coil,rcsc-evr3-00,blue star, control transformer,eatdz0020,blue star
Tender For spare parts of scania - hose part no 283136, dust cover part no 190335, seal ring part no 214309, seal ring part no 164900, hose part no 811195, hose part no 188283, control part no 1104198, dash board lock part no nk, head light assy part no 389483, cover part no 310518, plate scania part no 352140, rear toe lock part no nk, lmg bracket part no nk, screw m8x16 part no 808293, oil dipstick (eng ) part no 271225, intermediate part part no 219516, filler tube part no 257754, drain cock (tap) part no 228491, hollow screw part no 17146, hollow screw part no 17384, fuel tank part no 292781, hollow union part no 377424, lock ring part no 804787, piston ring part no 244186, plug part no 244465, plug part no 129386, drive part no 389606/389672, piston part no 367124, disk, outer part no 194428, disc, inner part no 194429, lock ring part no 804793, switch part no 328655, cover part no 317203, intermediate piece part no 254757, regul. valve, front part no 390485, regul. valve, rear part no 390487, elbow connection part no 161901, temperature monitor part no 334383, shim 0, 5 mm part no 274416, drain tube part no 224266, solenoid valve part no 1115802(350127), elbow connector part no 208405, reducing nipple part no 244439, sensor(speed) part no 284154, oil cooler part no 391173, connector part no 275052, journal part no 264043, lubricator part no 806311, three-way nipple part no 248351
Tender For bid to ras supply of ceiling speakers , column array speakers , amplifier for ceiling speakers , amplifier for column array speakers , digital signal processor , boundary layer microphones , on off button for boundary layer microphones , switch box for boundary layer microphones , ceiling tile microphone array , main display , side display , annotation panel , cable manager for table , hdmi switcher , hdmi splitter , hdmi extender , usb tx multiformat switcher , usb rx multi format switcher , usb data matrix switch , ptz camera , speaker tracking camera , hdmi to usb capture card , voice tracking device , control system with touch controller , network switch , room scheduler , pdu with humidity and temperature sensor , ceiling mount document scanner , equipment rack , ups 10 kva ups with 60 min backup , ups 3 kva ups with 60 min back up , acoustic door with fitting laminate and door frame , chair , hot and cold ac 2 ton , room air purifier , bio metric door access control , auto fire suppression system for av rack , high quality wireless keyboard and mouse , led surface recessed mounted panel with luminous web , 12 channel signal dimmer controller , 12 channel controller , display keypad panel for workstations , network router for automation system , sitc supply installation testing and commissioning , acoustic wall paneling , acoustic false ceiling , wooden conference table , executive chair , acoustic carpet flooring , power supply for lighting control network , lighting control communicaiton gateway
Tender For corrigendum : provision of electrical equipment against ber equipment held on charge of ge i cg goa - taking down existing industrial socket, indoor/outdoor unit of split type acs of any capacity and size with voltage stabiliser etc. contractor will carefully remove the aforesaid equipment from site and deposit to mes store under age e/m goa complete all as specified and directed., taking down old aluminium/copper sub main wiring of any type and capacity incl. all accessories and all as directed. note : (i) old dismantled wiring and accessories will be contractors property and credit will be charged against schedule of credit., supply and fix split air conditioner inverter type unit wall mounted, high wall split units indoor & outdoor complete with provision of cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with bee 5 star rated and capacity 1.5 tr, single phase 240 volts, 50 hz complete all as directed by engr-in-charge. make: voltas, lg, bluestar, hitachi., supply and fix split air conditioner inverter type unit wall mounted, high wall split units indoor & outdoor complete with provision of cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with bee 5 star rated and capacity 2.0 tr, single phase 240 volts, 50 hz complete all as directed by engr-in-charge. make : voltas, lg, bluestar, hitachi., supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 v with output voltage stabilized at 230 v with accuracy of 2.5% and of capacity 4 kva. make: v-guard, luminious, microtek., supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 v with output voltage stabilized at 230 v with accuracy of 2.5% and of capacity 5 kva. make: v-guard, luminious, microtek., m & l for sub main wiring with two runs of single core 4 sqmm frls copper conductor pvc insulated unsheathed cable as per is 694-1990 (third revision) drawn through & incl casing and caping of suitable size with all accessories such as tees, elbows,couplings, junction boxes etc, as required fixed on wall along with one run of 4 sqmm single core frls insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. note : (i) two runs of phase & neutral wire, one run of earth continuity conductor cable and one run of casing & capping will be measured as one unit for payment purpose.(ii) the wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads., s & f single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole c series mcb 20 amps complete all as specified., supply and fix refrigerators not less than 310 litres, electric driven (single phase), bee 5 star rate with the following features i.e frost free, double door, auto defrost to stop ice builtup, adjustable temperaturecontroller, double door with separate compartment for freezer inverter type compressor with energy efficiency of 5 star rating, tuffened glass shelf complete with an overall product warranty of one year & 10 year on compressor complete including all as specified and directed. note - old removed item shall be deposited in mes store., supply and fix electric water heater, storage type fibre body with copper heating element upto 2 kw capacity 25 litre, bee 5 star rated complete with all accessories such as safety valve, thermostate, nrv, pvc connection pipe and plug top 15 amps etc. including taking out unserviceable one complete all as specified and directed. note - old removed geyser shall be deposited in mes store. make orient cat
Tender For bench top pressure gauge calibrator with accessories- pressure calibration system, maximum no. of pressure module simultaneously, working medium, mode, sensor module range 1, accuracy of sensor module range 1, sensor module range 2, accuracy of sensor module range 2, precision, uncertainty of sensor module range 1, uncertainty of sensor module range 2, measurement modules, control mode, control precision, lowest controllable pressure limit, pressure indication & display system, over pressure protection, leak test & switch test, jog wheel, system mode, valve driver, vacuum pump, contamination prevention system, pressure display units, dc voltage range, dcv resolution, dcv uncertainty, dc current range, dci resolution, dci uncertainty, loop compliance voltage, hart mode, automatic hart detection, hart selectable resistor, write protection, hart commands, remote communication interface hardware, ac power supply, operating temperature range, relative humidity, ingress protection, plumbing lines, fittings and adaptors, warranty, calibration certificatte, test port max. pressure limit, reference port max. pressure limit, vent port max. pressure limit, test port, supply port max pressure limit, liquid or particle filter
Tender For bid to ras supply of self regulating heating tape cable e e - title1 , title2 , title3 , title4 , title5 , title6 providing self-regulating heat tape / resistance heating cable suitable for freeze protection of pipelines and utilities, having rated output of 35 w per meter at 220 v ac supply. the heating cable shall automatically adjust its heat output based on surrounding temperature conditions to prevent freezing and overheating. the cable shall be suitable for continuous operation in outdoor conditions, flexible for installation around pipelines, joints and valves, and compatible with temperaturecontroller systems., providing m20 3-pin connector suitable for making secure electrical joints between self-regulating heat cable terminals, designed for reliable power and signal continuity. the connector shall be rated for operation at 220 v ac supply and compatible with heating cables of specified capacity. it shall ensure safe and firm termination, with robust insulation to prevent moisture ingress, short circuits, and electrical leakage.the connector shall be constructed from high-quality, weather-resistant materials, suitable for continuous outdoor operation under varying environmental conditions. it shall provide ease of installation, with a compact and durable design for use at pipeline joints, terminations, and interconnections. the m20 connector shall be compatible with temperaturecontrol systems and associated accessories, ensuring long-term performance, safety, and protection against overheating, corrosion, and mechanical stress., providing temperature differential controller with auto and manual operation, housed in a robust ip65-rated enclosure, suitable for controlling heat tracing systems to prevent freezing of pipelines and utilities. the controller shall be designed to automatically switch the heat tape on/off based on preset temperature ) /bid number : gem/2026/b/7550906 * /dated: 18-05-2026 & & / bid document 1 / 13