Web Analytics Made Easy - StatCounter

Temperature Control Tenders

Get complete information related to latest Temperature Control Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Temperature Control Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Temperature Control Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45227596 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For corrigendum : supply of welding electrode drying portable oven with digital indicator, 5kg capacity, empty weight 5 kg max, inner dimension 70x70x480 mm3, input 240+_ 10 volt, 50 hz, single phase, 300 watt mini, electrode length suitability 450 mm, thermostat controlled, auto-power cutoff ensures stability at set temperature, temperature range 50- 400 degree c, insulation type - glass wool, nabl/oem calibration certificate shouldbe provided along with material, digital display with temperature controlled . make- fhp, esab, ador, memco or equivalent [ warranty period: 30 months after the date of delivery ] ]

corporations/Associations/Others

CTN :45294905 Due date: 03 Jun, 202603 Jun, 2026 2.97 Lacs
Tender For supply and installation of various electrical equipments in place of burn out and damaged ones at different panels and allied works at shanagar burning ghat. - supply and delivery of mccbs with thermal magnetic release breaking capacity thermal release rang 125-160a, breaking capacity icu at 415v ac, 50hz, 50ka4pole , supply and delivery of thermal overload relays (make: l & t/abb/schneider/simence/ ge/minilec) of the following range: 24-40, mn2, , power contactors: supply and fixing the power contactor t.p 70a, l & t make (ml-4) having 240v, 50hz, coil incl. 2 no + 2 nc aux contact block., , power contactors: supply and fixing the power contactor t.p 16a, l & t make having 240v, 50hz, coil incl. 1no+1nc aux contact block., , supply & fixing of 415/440 volt, hrc fuse (make: l&t/havels/cgl/ge).for 250 amp supply and fixing of analog ammeter ranging 0-100amps having c.r ratio of 100/5a, 144 mm sq size (make: ae/kappa/mp)., , supply and fixing of analog voltmeter ranging from 0-500 v of 144 mm sq size (make: αε/καрралмр)., , supplying and fixing 415v, tpn sfu open execution in existing ss enclosure/cubical with nuts bolts etc incl. s & f 3 nos. din type hrc fuse as per rating. 125a siemens, , supplying and fixing 240/415 v mcb of breaking capacity 10ka & c characteristics on din rail of existing dbs and necessary connection legrand 63 a fp, , supplying of 1.1 kv. grade pvc insulated conductor of following cables (make: polycab/gloster/havells/):size in sq. mm, no & dia. of wire in mm, no of core - 4 1/2.24 3, , annexure - i basic rate of materials: (all rates of materials from k-1 to k-14 are excluding vat) 70.1.5 sq.mm 'fr' stranded copper wire, , compression glands.supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture(proof entry of xlpe/pvc armoured cables as below: for, , 3 core.(i)upto 4 sqmm, , finishing cable ends.(b)finishing the end of following xlpe/pvc, , armoured cables by crimping method incl. supplying and fixing solderless socket (dowels make), tapes, anticorrosive paste & jointing materials. (ii) 2 core 6 sqmm cable, , temperature controller: a) supply and fixing the digital type temperature controller of range (0-1200) deg. c of overall dimension 92 sq mm dia x 105mm depth having (cr-a1) heat sensor and 1 no + 1 n.c change over contact to be actuated at crossed of desired temperature in deg.c complete power supply unit of 230v 50 hz., , blue max make

CTN :45318277 Due date: 09 Jun, 202609 Jun, 2026 50.00 Lacs
Tender For supply of cooling pad 2 feet x 4 feet with fitting , cooling pad frame alluminium 2 feet x 4 feet , water circulation pipe for pad frame , repairing fogger system with fogger and material , green net , insect net , gi profile with installation , zigzag spring with installation 8 mm , fogger with lpd with installation , uv stabilized film , uv stabillized film greennet insect net installation labour , exhaust fan with installation , 15 w solar street ligh system set with installation , 15 w solar street light repering work , motor repairing 1.5hp , 2 hp three phase exhaust fan motor repairing , 2 hp three phase exhaust fan new motor with installation , gi pipe 1.5inch 2 mm thikness with fitting , gi pipe 2inch 2 mm thikness with fitting , repairing of panelboard , 2 core 4 sq cable with fitting , 3 core 4 sq cable with fitting , 4 core 4 sq cable with fitting , fiber or pvc gutter with fitting , temperature controller with fitting , humidity display with fitting , fogging auto controller with fitting , bedsheet 100 micron , fabrication work , electric work , plumbing work upvc pipe and fitting 50 mm , plumbing work pvc pipe and fitting 63 , micro irrigation facility for plantation , micro irrigation facility for hitech nursery , 16 mm lateral with installation , 16 mm inline with installation , 8 lph dripper with fitting , inverted modular sprinkler or fogger sytemt for nursery , installation of foundation pipe pole digging and civil material without pole , hp solar controllar , hp solar motor pump , 545 watt solar panel with fitting , 50 mm10 kg isi hdpe pipe , remove damage uvsheet greennet insecti net profile

CTN :45319421 Due date: 06 Jun, 202606 Jun, 2026 1.80 Lacs
Tender For supply of humidity & temperature control device 02 tons (including instalation)

CTN :45291859 Due date: 01 Jun, 202601 Jun, 2026 NA
Tender For supply of humidity temperature control system 2 ton , humidity temperature control system 1 point 5 ton , power alternator 5 kva , power alternator 4 kva , ac stand, wire and mcb box , instl charges

CTN :45281561 Due date: 11 Jun, 202611 Jun, 2026 59.46 Lacs
Tender For tender for supply of fixing self regulating heat tape cable insulation and accessories in ppr pipe - providing and fixing self regulating heat tape resistance heating cable suitable to protect freezing of water in pipelines having rated output of 35 w per meter at 220 v ac supply the heating cable shall have capabibility to automatically adjust its heat output based on surrounding temperature conditions to prevent freezing and overheating the cable should be suitable for continuous operation in outdoor in adverse climatic conditions flexible for installation around pipelines joints and valves and compatible with temperature controller systems , providing m20 3 pin connector suitable for making secure electrical joints between self regulating heat cable terminals designed for reliable power and signal continuity the connector should be operable for operation at rated 220 v ac supply and compatible with heating cables of specified capacity must l ensure safe and firm termination with robust insulation to prevent moisture ingress short circuits and electrical leakage the connector shall be made up from high-quality weather resistant materials suitable for continuous outdoor operation under adverse environmental conditions it should be ease in installation with a compact and durable design for use in pipeline joints terminations and interconnections the connector should be compatible with temperature control systems and associated accessories ensuring long term performance safety and protection against overheating corrosion and mechanical stress , providing temperature differential controller with auto and manual operation housed in a robust ip65 rated enclosure suitable for controlling heat tracing systems to prevent freezing of water in pipelines and utilities the controller should be capable to automatically switch the heat tape on off based on preset temperature differentials ensuring optimal performance and energy efficiency the controller should have in built safety features such as overrun protection and burn out protection to safeguard the heating cable and associated equipment from damage the enclosure shall be weatherproof and suitable for outdoor installation offering protection against dust and water ingress and ensuring reliable long term operation under harsh environmental conditions , providing pt100 temperature sensors with 10 metre cable suitable for accurate temperature measurement and control in heat tracing and pipeline monitoring applications the sensors should be made up of platinum resistance type pt100 ensuring high precision stability and reliability over a wide temperature range the wire with sensor should have high quality insulation suitable for reliable signal transmission and compatible with temperature controllers and monitoring systems the cable shall be durable flexible and suitable for installation in outdoor under extreame weather conditions in high altitude area , providing 3 core 1.5 sq mm pvc insulated and pvc round sheathed multicore flexible cable comprising bright annealed bare copper conductors suitable for heavy duty industrial applications rated for voltage grade up to 1100 volts the cable shall confirm to requirements of is 694 2010 the conductors shall be made of high-conductivity annealed copper ensuring efficient current carrying capacity and minimal losses each core shall be uniformly insulated with high-quality pvc compound and the overall cable shall be protected with a durable pvc outer sheath providing resistance against moisture abrasion and mechanical stresses the cable shall be flexible in nature allowing ease of installation in confined and complex routing conditions it should be suitable for continuous operation in indoor and outdoor adverse environments offering reliable performance electrical safety and long service life

Central Government/Public Sector

CTN :45050054 Due date: 25 May, 202625 May, 2026 NA
Tender For instant water heater (geyser) in capacity of 1 liter horizontal wall mounting. abs outer body,inner tank stainless steels power supply 230 volts ac, 50 hz, power consumption 3.0-4.5 kw. length of flexible cable two meter with 3 pin plugs of 16 amps. safety features heating element insulation incoloy glass coated safety device/thermostat/auto temperature control, safety value pressure value flow switch, temperature indication/display test report along with an offer from central govt. accredited labs nabl/ilac. conforming to is: 8978 latest and is: 302-2-35 (specification for safety of house hold and similar electrical appliance, part-2, section-35). make:- bajaj, recold, havells or similar. [ warranty period: 30 months after thedate of delivery ]

Central Government And Public Sector

CTN :45297429 Due date: 02 Jun, 202602 Jun, 2026 NA
Tender For supply of temperature controller (q3)

Central Government/Public Sector

CTN :45002129 Due date: 28 May, 202628 May, 2026 NA
Tender For corrigendum : supply of temperature control valve

State Government

CTN :45287660 Due date: 06 Jun, 202606 Jun, 2026 18.00 Lacs
Tender For temperature-controlled logistics system for transportation of biological samples for hiv-1 viral load testing under the national aids control programme
 Loading, Please wait...

Connect us via What's Up