Get complete information related to latest Temperature Detector Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Temperature Detector Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Temperature Detector Tenders.
Tender For corrigendum : supply of temperaturedetector fenwall 71 c, part no: 28021-5-160f-2305 oem: m/s fenwal controls , converter pt100 4-20ma, sucessuor part no: mini mcr-2- rtd-uipt old part no: 2864286 oem: m/s phoeni , clockwise operation limit switch type f45, fitted with fci 10m connector plug and simple lever, part
Tender For bid to ras supply of resistance temperaturedetector pt-100 (rtd) , k type thermocouple ( immersion length 650 mm) , k type thermocouple ( immersion length 400 mm)
Tender For corrigendum : tender for supply of bulb 24v 40w b15 , bulb 40w , glass globe joint , o ring joint , bulb 115 60w b22 , bulb 24 v 40 w b15 , bulb 24 v 40 w b15 , bulb quartz iode 120v 250w , optical class , optical glass joint , pressure switch sensing element for fplm34dtxnsn , pressure switch sensing element for fplm34dkxsn , pressure switch sensing element for fpm34dqxnsn , temperature switch sensing elements for fcm34dgnsn , temperature sensor type pt 100b with ss316ti heath , configurable electronic module with pcb for emi protections , programmable temperaturedetector with 110mm probe length , temperature sensor assembly without electotronic module lm 176 , temperature sensor assembly without electotronic module lm 196 , flowrate signal processing unit amesys internation , typr 14p limit switch with a 20 m cable , 24 v aquacel type l37 reserve battery , pressure transmitter 0 15 bar absolute g 1 4 female , proximity detector neb 12 18mg50 e2 , remote thermometer 100mm type form 0 to 100 deg g full , thermometer 0100mm type a 0 to 100 degree c fcapillary k 2 m , manual call point , smoke detector , input module , limit switch contact , 1 0 m maximum height fresh water tank 1 level gauge , absolute pressure switch , conduct electrode h20 detect device al threaded coupling , differential pressure switch sensing element , electronic for fmb52 , electronic insert fel54 relays dpdt , level transmitter fmb52 , level transmitter fmb52 , position detector end valve fresh air pipe cm e 14 g21 3 , posn detector end vv air pipe cm e 14 g21 3 , pressure switch sensing element , pressure switch sensing element , pressure switch sensing element , pressure switch sensing element , pressure swith sensing element , pressure 60l alimentary quality balloon horiz or vert , dc dc converter , relay 2rt10a 28vcc , relay 4rt10a 28vcc , relay tpr2 28vcc , relay 6rt10a 28vcc , relay 6rt10a 28vcc , fuse series psc type 6 6 urd 30 tt f 0200 , cartridge fuse ha22 type 6 3 32 6 3 a , cartridge fuse ha22 type 6 3 32 1 6 a , monostable relay 10a 28vdc type 4 i 10 b1 p 28 , berard acturator oa8 115b 60 hz 3ph marline ral7038 , 115v 24 vdc converter , relay2rt 10a 28vdc suppressed device saphir code rel005appar , relay4 rt 2a 28vdc dc p
Tender For supply and installation of linear heat detection (lhd) cable in luggage portion as per rdso spec no rdso/2013/cg-06 or latest make: sanrok. the scope of work for coach alteration (luggage compartment area):- a) provision of 20 meter. linear heat detector (lhd) cable (ul or en approved, 105110 c), junction box and connecting cable including required accessories. b) installation of latest software. c) configuration of the system to be made so that on receiving fire signal from luggage compartment the buzzer should sound and dg set should shutdown. d) configuration of the system to be made so suppression system should not take place automatically. [ warranty period: 30 months after the date of delivery ] ]
Tender For repair and comprehensive maintenance of swimming pool plant and equipments fire fighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of fire fighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit fire fighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all fire fighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressable manual call point / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and directed., supply
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperaturedetector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign
Tender For purchase of lab equipments for res dept - purchase of lab equipments for res dept, rc phase shift oscillator (iemcode:o001)specifications: oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram., strain guage characteristi cs kit(iemcode:o002)specifications: ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. no rs.10,000 2 table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristi cs kit(item code: o003)specifications:input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer(item code: o004)specifications: input supply: 230 v / 50 hz ac withregulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter(item code: o005)specifications: input supply: 230 v / 50 hz acwith regulated internal dcsupply unit. measurement principle:buoyancy(archimedesprinciple) using displacerelement tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement oftemperature using pt100(item code: o006a)specifications: input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperaturedetector (rtd) probe with stainless steel sheath measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to
Tender For supply and installation of linear heat detection (lhd) cable in luggage portion as per rdso spec no rdso/2013/cg-06 or latest make: sanrok. the scope of work for coach alteration (luggage compartment area):- a) provision of 20 meter. linear heat detector (lhd) cable (ul or en approved, 105110 c), junction box and connecting cable including required accessories. b) installation of latest software. c) configuration of the system to be made so that on receiving fire signal from luggage compartment the buzzer should sound and dg set should shutdown. d) configuration of the system to be made so suppression system should not take place automatically. [ warranty period: 30 months after the date of delivery ] ]