Tender For installation of various instruments and monitoringsystem at vadi irrigation scheme - supplying, installing, testing, and commissioning of a v-notch weir mechanical flow measuring device) for measuring low flow seepage in dams. the device shall have a notch angle of 22.5°, 45°, 60°, or 90° depending on discharge range, a stainless steel ss-304 / ss-316 plate with thickness of 3–5 mm, and be suitable for measurement ranges of approximately 0–50 l/s depending on notch angle. the weir shall have ±1% full-scale reading accuracy, operate under 5–100% humidity, temperature −20°c to +60°c, and provide corrosion protection through anti-corrosion finish. complete in all respects as directed by the engineer-in-charge.with different sizes mentioned below: (1) 90° vnotch- 20 x 40 secticin 15 lit/sec, providing, installing and commissioning permanent ground control point (gcp) settlemnt marker comprising ms base plate (250×250×5 mm conforming to is 2062), gi riser pipe 25 mm dia (medium class as per is 1239), sand filling (clean river sand, loose), optional pvc/gi outer casing (min 100 mm dia), precast concrete cover (m20, 500×500×50 mm with central hole), ms/gi reference cap, and painting in black & white checkerboard pattern using weather-resistant enamel paint, complete with excavation, installation, alignment, and all materials, labour, tools, and accessories, suitable for survey works using total station / drone survey, complete as per specifications and direction of engineer-in-charge., providing & laying in position 'nominal mix' cement concrete using cement sand and crushed aggregate by machine mix incl. necessary formworks ,centering ,scaffolding compaction by mechanical vibrator curing as directed with all lead & lift etc (c) concrete grade 1:2:4 and msa-40mm(graded))
Tender For installation of various instruments and monitoringsystem at thebi irrigation scheme - supplying, installing, testing, and commissioning of a v-notch weir (mechanical flow measuring device) for measuring low flow seepage in dams. the device shall have a notch angle of 22.5°, 45°, 60°, or 90° depending on discharge range, a stainless steel ss-304 / ss-316 plate with thickness of 3–5 mm, and be suitable for measurement ranges of approximately 0–50 l/s depending on notch angle. the weir shall have ±1% full-scale reading accuracy, operate under 5–100% humidity, temperature −20°c to +60°c, and provide corrosion protection through anti-corrosion finish. complete in all respects as directed by the engineer-in-charge.with different sizes mentioned below: (1) 90° vnotch- 20 x 40 secticin 15 lit/sec, providing, installing and commissioning permanent ground control point (gcp) settlemnt marker comprising ms base plate (250×250×5 mm conforming to is 2062), gi riser pipe 25 mm dia (medium class as per is 1239), sand filling (clean river sand, loose), optional pvc/gi outer casing (min 100 mm dia), precast concrete cover (m20, 500×500×50 mm with central hole), ms/gi reference cap, and painting in black & white checkerboard pattern using weather-resistant enamel paint, complete with excavation, installation, alignment, and all materials, labour, tools, and accessories, suitable for survey works using total station / drone survey, complete as per specifications and direction of engineer-in-charge., providing & laying in position 'nominal mix' cement concrete using cement sand and crushed aggregate by machine mix incl. necessary formworks ,centering ,scaffolding compaction by mechanical vibrator curing as directed with all lead & lift etc (c) concrete grade 1:2:4 and msa-40mm(graded))
Tender For maintenance of electrical installation & fans in nscs at sardar patel bhawan, new delhi. (sh : providing wireless busbar temperaturemonitoringsystem for lt panels at sub station.)
Tender For supply, installation & commissioning of set of items for real time wireless self powered traction motor temperaturemonitoringsystem with generation of alerts suitable for bhel ac emu rakes as per specification attached. [ warranty period: 30 months after the date of delivery ] ]
Tender For upgradation of existing electrical and mechanical services at govt. of india press, minto road, new delhi. (sh: providing & fixing of wireless bus bar temperaturemonitoringsystem for hvac lt panel at govt. press of india)subwork/packages:providing & fixing of wireless bus bar temperaturemonitoringsystem for hvac lt panel at govt. press of india)
Tender For corrigendum : design, engineering, supply, installation and commissioning of online temperaturemonitoringsystem in 415v lt switchboards at prpc, panipat
Tender For providing of customized amc/cmc for pre-owned products - 1st year annual maintenance charges for existing hot box temperaturemonitoringsystem (4 field visits per year per hbd); iqnet; comprehensive maintenance contract (cmc); as mentioned in tender bid document..,customized amc/cmc for pre-owned products - 1st year annual subscription: tier iii level data centre based cloud application, intelligent field devices and communication charges with ultimate role based access from anywhere over internet browser for ..,customized amc/cmc for pre-owned products - 2nd year annual maintenance charges for existing hot box temperaturemonitoringsystem (4 field visits per year per hbd); iqnet; comprehensive maintenance contract (cmc); as mentioned in tender bid document..,customized amc/cmc for pre-owned products - 2nd year annual subscription: tier iii level data centre based cloud application, intelligent field devices and communication charges with ultimate role based access from anywhere over internet browser for ..,customized a
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - onboard ins sindhuratna at naval dockyard mumbai; installation, stw & commissioning of anadig make battery temperaturemonitoringsystem (cakt-06) including trials onboa..
Tender For providing of customized amc/cmc for pre-owned products - --; --;annual maintenance contract (amc) with calibration for temperaturemonitoringsystem (tms) – 05 nos. installed with scientific instruments (-80 degree, -20 degree, 4 degree, co2 incubators) in bsl-3 facility, bioassay lab and biorepository lab under thsti, ncr biotech science cluster, faridabad