Get complete information related to latest Terminal Block Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Terminal Block Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Terminal Block Tenders.
Tender For corrigendum : supply of set of cable disconnection tm-1 to tm-6 (terminalblock, tm-cables) specn: clw/es/3/0128/e [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of motor protection circuit breaker (mpcb) for water pump with auxiliary contact (1 no + 1nc)and terminalblock db, current rating: 1-1.6 amp,thermal release range :1.0 to 1.6 a, voltage rating 690 v, class 10, breaking capacity: 50 ka, 3 pole as per rdso spec no: rdso/pe/spec/0192-2018 (rev.1) or latest. suitable for use in switch board cabinet of lhb type ac coaches. make: abb/schneider/siemens/l&t. [ warranty period: 30 months after the date of delivery ] ]
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be
Tender For supply of de brg for nd160mb3r2 cg motor drive end and non-drive end bearings of each type , nde brg for nd160mb3r2 cg motor , cooling fan for nd160mb3r2 cg motor , motor terminalblocks assy nd160mb3r2 cg , de brg for ns132sb3r2 cg motor , nde brg for ns132sb3r2 cg motor , cooling fan for ns132sb3r2 cg motor , motor terminalblocks assy ns132sb3r2 cg , de brg for nd250mxb3r2 cg motor , nde brg for nd250mxb3r2 cg motor , cooling fan for nd250mxb3r2 cg motor , motor terminalblocks assy nd250mxb3r2 , de brg for ns112mb3r2 cg motor , nde brg for ns112mb3r2 cg motor , cooling fan for ns112mb3r2 cg motor , motor terminalblocks assy ns112mb3r2 cg , de brg for nd225m cg motor , nde brg for nd225m cg motor , cooling fan nd225m cg motor , motor terminalblocks assy nd225m
Tender For scope of work (sow) as mentioned in tender and schedule of work( 46 )items as given below ,[1] remvg 1hp,400v,3ph,50hz,1500rpm motor 4.000 ea,[2] remvg 3hp,400v,3ph,50hz,1500rpm motor 2.000 ea,[3] remvg 5hp,400v,3ph,50hz,1500rpm motor 4.000 ea,[4] remvg 7.5hp,400v,3ph,50hz,1500rpm motor 4.000 ea,[5] remvg 10hp,400v,3ph,50hz,1500rpm motor 2.000 ea,[6] remvg 15hp,400v,3ph,50hz,1500rpm motor 2.000 ea,[7] remvg 20hp,400v,3ph,50hz,1500rpm motor 2.000 ea,[8] remvg 30hp,400v,3ph,50hz,1500rpm motor 1.000 ea,[9] remvg 40hp,400v,3ph,50hz,1500rpm motor 2.000 ea,[10] remvg 60hp,400v,3ph,50hz,1500rpm motor 1.000 ea,[11] remvg 70hp,400v,3ph,50hz,1500rpm motor 1.000 ea,[12] remvg 1hp,400v motor,party to dispose 6.000 ea,[13] remvg 3hp,400v motor,party to dispose 2.000 ea,[14] remvg 5hp,400v motor,party to dispose 4.000 ea,[15] remvg 7.5hp,400v motor,party to dispose 4.000 ea,[16] remvg 10hp,400v motor,party to dispose 2.000 ea,[17] remvg 15hp,400v motor,party to dispose 3.000 ea,[18] remvg 20hp,400v motor,party to dispose 3.000 ea,[19] remvg 30hp,400v motor,party to dispose 1.000 ea,[20] remvg 40hp,400v motor,party to dispose 2.000 ea,[21] remvg 60hp,400v motor,party to dispose 2.000 ea,[22] remvg 70hp,400v motor,party to dispose 1.000 ea,[23] supply of motor bearing,1 hp motor 8.000 ea,[24] supply of motor bearing,3 hp motor 2.000 ea,[25] supply of motor bearing,5 hp motor 8.000 ea,[26] supply of motor bearing,7.5 hp motor 5.000 ea,[27] supply of motor bearing,10 hp motor 2.000 ea,[28] supply of motor bearing,15 hp motor 2.000 ea,[29] supply of motor bearing,20 hp motor 2.000 ea,[30] supply of motor bearing,30 hp motor 2.000 ea,[31] supply of motor bearing,40 hp motor 2.000 ea,[32] supply of motor bearing,60 hp motor 2.000 ea,[33] supply motor bearing,70hp/15hp vertical 3.000 ea,[34] supply&replcg of motor terminalblock 15.000 ea,[35] testg nonwrking motor,various capacity 15.000 ea,[36] disconnect&remvg defective motor starter 15.000 ea,[37] reprg burnt/damaged motor stator lead 25.000 ea,[38] remvg faulty portion of motor main cable 16.000 ea,[39] layg of cable on wall/surface as per eic 95.000 m,[40] layg cable thr'rcc/hume/gi/open trench 45.000 m,[41] layg cable thr'excav underground trench 45.000 m,[42] disconnection of cable 6mm2 to 16mm2 10.000 set,[43] disconnection of cable 25mm2 to 70mm2 10.000 set,[44] cleang & paintg of motor 1hp5hp 16.000 ea,[45] cleang & paintg of motor 7.5hp20hp 10.000 ea,[46] cleang & paintg of motor 30hp70hp 6.000 ea
Tender For tender for supply of outdoor full hd day and night ptz ip camera , camera mounting bracket heavy duty gi , camera junction box weatherproof , spike buster 4 port , camera pole gi 6 mtr with stair provision , pvc pipe heavy duty , pvc box 3x3 , led light 50w ip66 , solar panel , gi pole for light 6 mtr , pole foundation rcc , outdoor jb for light termination , ofc 6 fiber cable , ofc joint closure , ofc liu 12 port loaded , ofc patch cord lc-sc , network switch 8 port poe with sfp slot , sfp module pair , outdoor utp cable , power cable 2 core x 10 sqmm , nvr 32 channel ip , nvr 16 channel ip , nvr 08 channel ip , hdmi cable 10 mtr , surveillance hdd 10 tb , led tv 75 inch , wireless mouse , network rack 27 u , 24 port network switch sfp modules , installation system testing transportation
Tender For supply of vacuum filter spares & service-spare parts of & work for 10 x 20 vacuum filter ,brass zig-zag 2 long ,s.s binding strip ,s.s. perforated screen ss 304 13 x 10 salem ss 304 (weight 1.72 kg.) ,heavy duty railway hose pipe size: 2 bore x 18 long ,s.s. bolt x ,scrapper belt 5 width 8 ply ,lead wire 3/8 ,s.s. decking plate 1 x 10 (ss 304) ,s.s. capillary pipe with s.s. junction box six way & main connecting pipe junction box to vacuum distribution valve (complete set) ,s.s. divisional strip ,copper rivet size below:- ,size: 4mm x 12 mm ,size: 5mm x 15 mm ,pvc spray nozzle ,m.s. connector (hexagonal) both & thread ,reconditioning work ,repairing charges of dismantling, refitting of damaged capillary, nipple, junction box 6 way along with column pipe upto vacuum distribution valve all work should complete in all respect both portion of 10 x 20 rotary vacuum filter, damaged decking plates replacement & fitting work to be completed, all ss perforated screen dismantling & refitting after cleaning of decking plates & damaged decking plate replacement. hydraulic testing to be done capillary section inside drum as well as drum to made leak proof, insure the trouble free working throughout the season 2026-27 damaged ss perforated screen replacement work in 2 nos. other filters (approx = 20 nos.)