Get complete information related to latest Terminal Connector Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Terminal Connector Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Terminal Connector Tenders.
Tender For auction sale of depot non ferrous scrap - brass lump scrap - 98200045(15) cond.& u/s brass lump scrap consisting of flow lamp, oxygen regulators, 63a 5 pin plug components, spcc panel components, catenary ending cones, catenary splices, bushes, bolts, nuts, gas cutting torches, gm valves, float valves, tap bib cock, cp angle valves, dropper clips, contact wire swivel clips, marut hand compression sprayer, brush holders, terminalconnectors, pg clamps, bracket direct clamps, steel wire ending cones, briddle wire dopper clips, rods, key spindle, nozzle type, dv components, trunnion body for bmbc, etc. available in the bin with or without other attachments. total gross weight: 865.6 kgs. said to contain total brass content: 845.501 kgs approx., total ms content: 5.65 kgs approx, total aluminium content: 5.194 kgs approx, total stainless-steel content: 3.14 kgs approx, and plastic, rubber, etc: 6.115 kgs approx. hsn code:74040022; gst@18% on forward charge basis. note: 1) delivery on actual weighment basis only 2) segregation not permitted. 3) purchasers/firms are requested to physically inspect the lot before offering their bids. 4) post auction no representation shall be entertained.5) it is the responsibility of the purchaser/bidder to return excess material, if found during gross weighment, to the nominated premises of the custodian. 6) request for fixation of delivery point should be invariably raised in ireps online only. purchasers are requested to make use of this facility. 7) railways does not guarantee for quality, quantity description etc. location: non-ferrous ward bin no: 1.
Tender For tender for supply of supply of hardware fittings and conductor accessories -33kv isolator jaw made of copper (m/s rama make isolator) having 1250 amp. , supply of 33kv isolator jaw made of copper (m/s rama make isolator) having 2000 amp. , supply of 33kv ct bi-metalic terminalconnector duly made of lm-6 alluminium alloy. twin acsr panther conductor , supply of 33kv cb bi-metalic terminalconnector duly made of lm-6 alluminium alloy. twin acsr panther conductor. , supply of lm -6 all-alloy 33kv ct clamp threaded type suitable for twin panther conductor. , supply of lm -6 all-alloy 132kv ct clamp pipe type suitable for twin panther conductor. , supply of terminalconnector of 132kv isolator suitable for twin panther conductor.
Tender For stage contract for carrying out various electrical maintenance works including sitc, itc of various line materials and distribution substations and dismantling of existing deteriorated out lived electrical infrastructure for the year 2026-27 under th - supply, installation, testing and commissioning of 3-phase 25 kva distribution transformers with bimetallic terminalconnectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 63 kva distribution transformers with bimetallic terminalconnectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 100 kva distribution transformers with bimetallic terminalconnectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 200 kva distribution transformers with bimetallic terminalconnectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 250 kva distribution transformers with bimetallic terminalconnectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, sitc of 11 mtr long st poles 410, sp-56 including transportation, manual, mechanical carriage, delivery at site with pit excavation, refilling the pit with soil, boulders., sitc of 9 mtr long st poles 410, sp-33 including transportation, manual, mechanical carriage, delivery at site with pit excavation, refilling the pit with soil, boulders., sitc of 8 mtr long st poles 410, sp-15 including transportation, manual, mechanical carriage, delivery at site with pit excavation, refilling the pit with soil, boulders., sitc of 8 mtr long pcc poles including manual, mechanical carriage, excavation of pole pits with inscription of permenent marking on each pole "name of scheme-2019-20/xx" (xxx mean pole numbers say 01,02...) in white paint in backgound of green paint at conspicious place, providing & fixing of pole earthing as per rec standard as per j-1 (spiral earthing) drawing, supply,fixing of spike earthing rod 20mm 2,5 mtr long with gi strip (25x3)mm, supply and painting of each pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint), providing, errection, testing & commissioning of channel cross arms, v-cross arms, sub-station channels & angle iron braces, transformer beltings, including back clamps for fixing cross arms etc fabricated out of galvanized iron of different sizes (rec standard) & to be fixed with gi nuts & bolts and washers., providing, errection, testing & commissioning of channel cross arms, v-cross arms, sub-station channels & angle iron braces, transformer beltings, including back clamps for fixing cross arms etc fabricated out of mild steel of different sizes (rec standard) & to be fixed with gi nuts & bolts and washers., providing & and fixing of 11 kv pin insulators (polymer) with pins ( 5 kn), providing & fixing of 11 kv, g.o ab switch , 3-phase, 200a (09 insulator post type) with arragement for pad locks & operating rod . the operating rod should be g.i pipe (b-class) of 25 mm dia of requisite length., providing & fixing of 11 kv horn, gap fuse 3-phase 100a, providing & fixing of 11kv link set 3-phase, 200 a (station type), sitc of 11kv isolator double break, 3-pole, 630 amps, horizontal mounting type , with earth switch, providing & fixing supply and installation of gapless surge arrestor,9 kv,10 ka, la with (polymer) housing, station type, providing & fixing of lt fuse set of suitable capacity for 63kva,100kva,200kva (as per tender drawing attached), providing & fixing of 11 kv disc insulators (polymer) complete with fitting( 45 kn), providi
Tender For supply of bi-metallic terminalconnector for (h. t) as per our drawings no. tg-a3-13330 rev. 0 , bi-metallic terminalconnector for (l. t) as per our drawings no. tg-a3- 13363 rev. 0
Tender For supply of pvc insulated armoured unscreened underground railway signalling power cable(aluminium conductor) size 2 core x 25 sq mm to rdso specification no irs:s:63/2014(rev.4.0) & is:1554(part-i) or latest, if any [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 2 %age , item category : special (signaling cables) , total po value variation permitted: not applicable ] ]
Tender For supply of pvc insulated armoured unscreened underground railway signalling power cable aluminium conductor as per rdso specification no irs:s63/2014 rev 4.0 and is:1554 part-i. size:-2 core x 70 sq mm. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 2 %age , item category : special (signaling cables) , total po value variation permitted: not applicable ] ]
Tender For supply and execution items for reliability improvement of signalling inst. section of sr. dste/1/lko of lucknow div. nr. - excavating and refilling of trench to the level of ground with rammed earth asper drg. no.(nr/s&t/con/1.1/97a) so as not to form a drain 0.3 mtrs wide & 1mtr deep on both side of the station along side the track. it shall confirm to the safe distance as per signalling and cable plan in all type of soil, it also includes clearence of roots of trees and bushes., excavating and refilling of trench 0.3 mtrs wide & 0.8 mtr deep on pitced/stone/bricks paved surface, road/crossing/platform etc. and restoration of surafce to original condition., laying of signalling/telecom/power cables of different sizes as per attached guidelines (drg. no.(nr/s&t/con/1.1/97a) or latest on signalling cable laying and as per cable route plan approved by railways through trenches, rcc pipe, dwc pipe, gi pipe etc and meggering of cable before and after its laying of all type of outdoor cables. contractor have to transport cable from any store of lko division to site carefully. meggering to be done for each drum separately. meggering sheets to be supplied and filled up by contractor and submitted to railways, as per instructions by consignee., supply and laying of 2nd class bricks in the trench and laying as per drg. no. (nr/s&t/con./1.1/97a) or latest and as per instruction of the site engineer., boring and trenchless cabling along with supply and insertion of hdpe/dwc self lubricated pipes as per rdso spec no. rdso/spn/204/2011 ver 1.1 or latest of 120mm nominal dia in the bore at the depth of 1.4 meter to 2.1 meter from formation level (level of earth below ballast) as per drawing and as directed by engineer incharge by trenchless technology for laying of signalling /telecom/power cable under track /culvert etc. cable laying covered separately. inspection-consignee for supply of dwc/hdpe pipe. the following required coupling arrangement should also be supplied: 1. suitable snap fit couplers withrubber o ring, 2. spacers, 3. tees. 4. bend. 5. end cap(1 no. =6mtr ,straigh tpipe). (a) the cost shall include horizontal boring through any intermediate obstruction, either natural or man made or any boundary etc. (b) the rate is inclusive of all the materials equipment and labour required for during trenchless horizontal boring under the railway track. nothing extra shall be admissible on any account than the rate quoted above. (c) the pipeis to be laid underrailway track/road /culvert. all necessary arrangement are to be provideand all precautions are to be end is not deviated from the horizontal level line by more than 250mm in horizontal and vertical direction. (d) the rate shall be inclusive of direction and protection of underground utilities encountered during boring. (e) the payment for boring shall be made only when dwc/hdpe pipe are laid in the bore., concreting unschduled items in concrete of 1:3:6 ratio in cement, coarse sand and aggregate 25mm at different places in the yard and plastering top in fine plaster of 1:4 cement sand ratio. it also includes the excavation of earth as required at site and as per instruction of site incharge. the volume in cubic metres shall include the volume occupied by any ci foundation, trestle, ms angle or flat or gi pipe required to be embedded in the casting. cement coarse sand and aggregate 25mm are to be supplied by the contractor., earth work for excavation and refilling around location boxes and signals etc. where necessary including 50m lead and 1.5m lift. the lead is to be measured from centre of gravity of location to the centre of filling and lift from main ground level. the earth work should be well rammed including breaking of clods, levelling and dressing etc. as per instruction of engineer at site., brick work with well burnt bricks in foundations and plinths with cement and sand (ordinary) mixture of 1:4 ratio. all material is to be supplied by the contractor.