Get complete information related to latest Terminal Lugs Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Terminal Lugs Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Terminal Lugs Tenders.
Tender For supply of outdoor type , plinth mounted, distribution transformer, minimum energy efficienc y level 3 of rating 500 kva, 3-phase, 11kv/415-240v,50hz, oil immersed, non-sealed type (transformer ta nk body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (ve ctor symbol- dyn11), onan cooled transformer, conforming to is 1180 (part1):2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest with condition that drain-cum-sampling valve. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 f) of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides bushing appropriate voltage and current ratings., low voltage side cable end box required. the high voltage bushings (3 nos.) shall conform to is/iec 60137. the low volt age bushings (4 nos.) shall conform to is 7421. off-circuit tap changer (applicable for all ratings above 20 0 kva) for variation of hv voltage from +5% to -10% in steps of 2.5%. following has to be submitted by su pplier along with supply of material: (i) type test report of transformer having same rating, make (& mode l if any) and design from nabl accredited lab as per is: 1180 (part 1) latest. (ii) routine test certificates as per is: 1180 (part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d) & (e) of is:11 80 (part 1) latest. supply of outdoor type , plinth mounted, distribution transformer, minimum energy effici ency level 3 of rating 500kva, 3-phase, 11kv/415-240v,50hz, oil immersed, non-sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star ( vector symbol- dyn11), onan cooled transformer, conforming to is 1180 (part1):2014 with amendment n os. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) late st with condition that drain-cum-sampling valve. oil temperature indicator & winding temperature indicato rs will be provided as per clause 20.2 f) of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides bushing appropriate voltage and current ratings., low volta ge side cable end box required. the high voltage bushings (3 nos.) shall conform to is/iec 60137. the low voltage bushings (4 nos.) shall conform to is 7421. off-circuit tap changer (applicable for all ratings above 200 kva) for variation of hv voltagefrom +5% to -10% in steps of 2.5%. following has to be submitted by s upplier along with supply of material: (i) type test report of transformer having same rating, make (& mod el if any) and design from nablaccredited lab as per is: 1180 (part 1) latest. (ii) routine test certificates a s per is: 1180 (part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d) & (e) of is:1 180 (part 1) latest. [ warranty period: 30 months after the date of delivery ]
Tender For bid to ras repair of transformer 400 kva outdoor type at af stn memaura : : - disconnecting of hv or lv cable from transformer 400 kva 11or 0point433 kv at site and loading and unloading of transformer at both side s or s a of age i af memaura and repair work premises hiring of crane and transportation charges to workshop from agei af memaura complete all as specified and directedpoint make vishal transformers switchgears pvt ltd sm nopoint 1843089tr04 01 each job , taking down and dismantlingopening up unserviceable transformer step down outdoor type 110point433 kv capacity 400 kva including lifting of core taking out unserviceable burnt winding after dismantling core stampings and draining of transformer oil and storing in a suitable container desludging and cleaning thoroughly rewinding and reinsulating of transformer as per the requirement maintaining existing specificationsize including reassembling core stampings lowering wound core within transformer outer cell and refilling transformer oil after sludge removal of dielectric strength 50 kv at least replacement of silica gel of breather reassembling testing for satisfactory performance and installation and commissioning in the existing position complete all as directedpoint note materials required for winding and insulation shall be measured and paid separately as supply only 01 each job , m l for changing of old burnt copper coil by new dpc copper coils with complete including insulation material of distribution transformer of capacity 400 kva complete all as specified and directedpoint 107 kg , dismantling of unserviceable lt bushing of transformer of capacity 400 kva and supply and fix new bushing including brass stud nuts washers and rubber bush complete all as directed by the engineerinchargepoint 02 each set , dismantling of unserviceable 11 kv ht bushing of transformer of capacity 400 kva and supply fix new bushing including brass stud nuts washers and rubber bush complete all as directed by the engineerinchargepoint 01 each set , supply and pour new transformer oil in replacement of approved quality dielectric strength not less than 50 kv isi marked for filling in transformer for topping up complete all as specified and directedpoint 370 ltrs , schedule of credit for old us items will be the property of contractor
Tender For supply of electrical line materials under adp head for f.y. 2025-26 under esa, giridih. - electrical items :, gi wire no. 8 for earthing, gi wire no. 7/16, gi wire no. 10 for earthing, pg clamp for 150 mm2 conductor, aluminium end terminallugs 400 sq. mm, aluminium end terminallugs 300 sq. mm, connector pipe to panther, connector panther to panther, connector panther to ab switch, connector pipe to ab switch, connector dog to ab switch, connector wolf to wolf, connector wolf to ab switch, rod type earthing [25 mm dia ms rod 3 mtr. long]
Tender For supply of mt head e e 0 oil seal front hub , oil seal rear shaft axle , gear lever bushing kit , self starter , accelerator pedal with sensor , deleted clutch assy , assy fuel filter , air filter , ac belt , relay 40a , bearing assy front , kit pad assy front , sensor wheel speed rear , sensor wheel speed front , assy clutch m cyl , assy parking brake cable , combination switch , wiper blade rear , wiper blade front
Tender For supply of 8 ton hydraulic jack with handle , bushing , jet puller assy , flap , oil cooler assy , repair kit msp 362 hand control valve , priming pump hand , rubber hose , rubber hose water pump to t connector , centre bolt , de spanner 516 38 bsf , tube extension 1-14 od x 10 bg thick 1 , assy fog lamp frontyellow lens lh , assy fog lamp frontyellow lens rh , assembly door lock rh , tommy bar with square drive head for ope , pole screw , de spanner 1516x34 bsf , handle axes pick head 2 kg , bulb turn signal 12v21w , wrench for lifting spare wheel assy , assy wiper blade , bulb head lamp 208v 60x40 , assy rear view mirror outside lh luma , assy rear view mirror outside rh luma , grease gun , tin rectangular 5 ltrs , de spanner 19x22 , tyre inflating hose with nipple 5.70m lo , philips head screw driver 100 mm long ti , eng screw driver 1.2x8x150 , first aid kit , tool bag for wheel wrench , warning lamp 4 4 low , tool bag , elementprimary , bolt steel m-24x1.5x80mm long lh , ring spanner 10 11 metric , inserter remover tube valve die , chisel 2810-0199 , screw driver 12 300mm , de spanner 18 19 , bucket water canvas 6 , tyre inflator hose , bulb , funnel oil 152mm , funnel fuel garrage pattern , allen key 12mm af , insp lamp with 10m cable comp w single , black out head lamp , triangle kit ) /bid number : gem/2025/b/6484037 * /dated: 28-07-2025 & & / bid document 1 / 49