Get complete information related to latest Terminal Pad Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Terminal Pad Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Terminal Pad Tenders.
Tender For supply of bimetallic terminal connector suitable for 25 mm dia, aluminium tubular bus bar to terminalpad of 3.3 kv isolator/ct with copper palm copper cu etp cw004l and aluminium barrel aluminium al 99.5cable connector temperature resilience, corrosion resistance confirming to is: 5561-1970 with maximum temperature rise of 90 degree elsius. material shall be confirmed to designation a6 of is: 61 7-1959. breakingresistance for barrel 85 n/m sq m and for palm 225 n/m sq m with stretching a5% for barrel must be for palm 35. (nabl certificate shall be submitted along with the offer) [ warranty period: 30 months after the date of delivery ] ]
Tender For running maintenance of plc system - running preventive and breakdown maintenance of plc control system with electrical drives all control and instrumentation system of ash handling , replacement new erection of impulse line , replacement new erection of instrument fitting adopter nut tails elbow connector etc , overhauling b 501 and b 601 ss cock valve , overhauling repairing of junction boxes , servicing recalibration erection of fuzi yokogava rosemount etc transmitters , overhauling and recalibration new erection of digital indicators , overhauling and recalibration erection of flow meter conductivity meter , complete overhauling erection of level switches , replacement of pressure switch gauge vibration switch , removal testing erection commissioning calibration of temp gauges switches thermocouple , replacement erection overhauling cleaning of union isolating valveforged body valve , blowing of tapping points of different pressure transmitters switches , fabrication repairing of instruments plateform , laying patrolling of instrumentation cable , servicing and maintenance of air conditioner , cleaning of control room plc system , repairing of ups , service replacement of faulty butterfly valves along with act , servicing replacement of faulty diaphragm type valves , changing spindle gland of root valves , cleaning blowing by air of impulse lines , attend leakage from steam water air line , replace gauges switches of pressure temp , testing caliberation of pressure gauges , testing calibration of pressure switches , testing calibration of temp gauges , testing calibration of temp switches , replacement of thermocouples , cleaning servicing of terminal block in compressor house swas system , changing of ss root valves , servicing of 10mm hp lp 3way manifold valves , replace of 10mm hp lp 3way mfold valves , removal choking replace of impulse line , erection replacement of pvc armored compensate cable , replacement of universal digital indicator , servicing replacement of faulty 4way valve with actuator , replacement remounting of smps 24 v dc , dismantling replacement of combination timerof compressor , servicing of sampling cooler dhx18 sco2 , servicing of sampling cooler dhx12 sco2 , servicing of sampling cooler dhx06 sco1 , miscellaneous mechanical febrication , maintenance of actuator of butterfly valve , maintenance and upkeep of terminal box of motor of actuators in cw pump , maintenance re erection of butterfly valve actuator motor , revisioning and upkeep of marp dcs panel , revisioning testing of various type of switches of local control panel , maintenance revisioning upkeep and testing of 415 v power supply module , maintenance upkeep and repair of junction box of butterfly valve , servicing of mov motors actuators and limit switch assembly , checking cleaning and cable dressing mov motor , overhauling cleaning reconditioning of various size batteries , load test once in six months for various size battery of ups installed for 5x200mw , replacement of damaged switches mcb in acdb panel , cleaning painting of the wooden battery stands , maintenance of window type split type ac , gas charging of ac , rewinding of burnt fan motor
Tender For auction sale of others - scrap non ferros brass items consiste of defective & worn out smgr, pipeline adapter, plunger, coupling vcb gauge, smgr cylinder cap, mg/6/6 valve, mg 4/4 valve, connection rod, control block, gun metal valve, aluminium bus bar )n type, o type, p type) connection link, arching horn, phge middle piece, phgr cylinder, smgr cylinder top cap, defective worn out isolating 3 way cock hom, three way ball valve acb dj part, clamp for terminal base & brush holder for hitachi tm, brush holder insulator for hitachi tm, smgr pipeline, smgr cylinderical cover, smgr piston rod, rps fuse putti, rps fuse link patti, hrc fuse 100 amp link, hrc fuse side link, hrc fuse side plate, strainer, legris cock, wsm tank, smgr push rod, hom isolating cock, rps fuse, mph impeller, cp safty valve, pantograph push rod end & differents brass part of equipment with or without ms attachment released from ac loco. weight= 1.571 mts (brass= 1.4544 mts, copper= 0.0234 mts, ferrous= 0.092 mts, insulation= 0.0017 mts). for custodian information ss-11 no. nkj/trs/scf/26-27/10 dt. 01.06.2026. ds-8 note no. 020725 dt. 01.06.2026. mode of delivery by actual weight only. (remark- 1. sale condition "as is where is basis" & uniform sale condition for e-auction is applicable. 2. the purchaser of the awarded lot are advised not to wait for last date of fdp considering the forthcoming mansoon season. all efforts should be made to lift the lot as early as possible.)
Tender For supply of regid bimetallic terminal connector suitable for 50 mm dia, alluminium tubular bus bar to terminalpad of 25 kv isolater/ct conforming to rdsos drg.no.re/33/p/11090 oras per drawing no. eti/psi/p/11090 or latest consisting of part no.11091 & 11092" complete with connector body and clamping piece. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of rigid terminal connector suitable for 20 dia aluminum conductor to terminalpad of 25 kv pt type-i and type-ii and isolator. (ri no.11121 & 11122) rdso spec: ti/spc/ohe/fittings/0130-10/13-rev-1 or latest, rdso drw: eti psi p 11120 or latest. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of rigid type bimetallic connector suitable for 50 dia aluminum tubular bus bar to terminalpad of 25 kv isolator/ct. (11091 & 11092) rdso spec: ti/spc/ohe/fittings/0130-10/13-rev-1 or latest, rdso drw: eti psi p 11090 or latest. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of terminalpad for under frame (modified) as per icf drg no.gs 7-1-007 alt.'p' [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of expansion type terminal connector to suit 50 mm dia al busbar to terminalpad of circuit breaker as per rdso drg. no. eti/psi/p/11060 rev e [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For corrigendum : supply of bimetallic rigid terminal connector to suit 50 mm dia al busbar to terminalpad of current transformer (ri no.11090) as per rdso drawing no. eti/psi/p/11090 rev c. [ warranty period: 30 monthsafter the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]