Get complete information related to latest Test Apparatus Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Test Apparatus Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Test Apparatus Tenders.
Tender For bid to ras supply of mme lab equipment : : -composite wall thermal conductivity apparatus , reynolds apparatus ss tank , pipe friction or pressure drop ss tank , fluidized bed pressure drop apparatus , packed bed pressure drop apparatus , orifice meter , bernoulli s apparatus , mercury , digital erichsen cupping machine , jominy end quench testapparatus
Tender For purchase of lab equipments for civil department - venturimeter and orifice meter apparatus (as per notice invaiting tender), pipe friction apparatus with all accessories (as per notice invaiting tender), centrifugal pump testing rig with all accessories (as per notice invaiting tender), aggregate impact testing machine (as per notice invaiting tender), reciprocating pump testing rig with all accessories (as per notice invaiting tender), flow table testapparatus (as per notice invaiting tender)
Tender For refer tender notice - purchase of non consumable item in material testing lab for civil department - torsion testing machine (code e006)function: conducts torsion and twist tests on materials. such as metal wires, tubes, and sheetstorque measurement : pendulum dynamometer systemtorque application : geared motor through a gearboxtorque range : adjustablematerial tested :metal wires, tubes, sheet materialsfloor-mounted electromechanical type,230 v ac, 50 hz power supply,digital display, sand replacement testapparatus (or) core cutter devices(code e014)metal tray / base platesquare metal tray with a central hole (e.g., 300 mm 300 mm with 100 mm hole).another common size: 450 mm square, 50 mm deep with 200 mm central hole for larger kits seamless steel cylinder with no sharp edges.common size: 100 mm internal diameter, 127 175 mm length (varies by kit). mkpequipments.com +1wall thickness ~3 mm (industrial products), total station with all accessories(code e022)leica flexline ts10 reflectorless total station angle accuracy: 1 5 (smaller values = higher precision). magnification: ~28x 30x optical zoom. distance range:with prism: 2,000 m 6,000 m+reflectorless: 600 m 2,000 m typical. battery backup: ~12 36 hrs field operation., rockwell cum brinell hardness testing machine with intentor set box(code e031)min initial test force :10kgf, total test force range : 60kgf,100kgf,150 kgf, max. height of specimen :215 mmmin distance from indenter center tomachine wall :132 mm accessories:steel ballpreferred indentor 1/16" preferred steel ball: 1/16"and with all standard accessories to run the machine
Tender For state plan-state plan 2025-2026-procurements of equipments for wtps-supply and installation of water quality testing equipments at wtps under ws section 1 attingal-general civil work-general civil work - purchase of jar testapparatus, od229090/2025-2026:supply and installation of the jar testapparatus must meet the following specifications. no. of. stirrers -6 minimum, rpm- 25 to 200 rpm or better, capacity of single stirrer unit-, control—digital control (digital timer & rpm counter), stirrer paddle material (with appropriate corrosion protective coating) - stainless steel, power single phase (220 - 240 volts), illumination—fluorescent tube such that illumination should not contribute heat to the system and entire equipment must have a minimum warranty period of two years, purchase of ph meter, od229087/2025-2026:supply and installation of bench top ph meter must with the following specifications: (a) regarding ph: the range must be between 0.00 to 14.00 ph or better, the resolution 0.01 or better, the accuracy 0.02 ph or better, the calibration points should be atleast 3 points, buffer option should be suitable for standard buffers. (b) regarding mv: range 0 to 1999 mv, resolution 1 mv or better, accuracy mv or better (c) regarding temperature: range 0.0 to 99 degrees celsius or better, resolution should be 0.1 degrees celsius or better, and accuracy of 0.5 degrees celsius or better. (d) the electrode of the ph meter must be a single junction, body plastic/unbreakable material, gel-filled electrode, and atc probe, and the electrode stand should also be provided by the supplier. (e) ph meter must also have lcd/led display, a dual display of ph or mv with temperature, with auto buffer recognition, offset/slope should be displayed, power 230v 10%, must provide a minimum of 100 ml of buffer solutions of ph 7.0, ph 4.0, and ph 9.2. the supplier must provide all accessories for smooth functioning of the equipment and a hard copy of the user manual with instrument specifications. the ph meter must have a minimum warranty of one year for the meter and a minimum of six months for the electrode. the calibration at the time of the installation must be done by the supplier., purchase of conductivity-tds meter, od229088/2025-2026:supply and installation of conductivity - tds meter with conductivity range of at least 0.1 s to100 ms, resolution : 0.001 s and tds range of 0.1 ppm to 100 ppt , temperature : 0 degree celsius to 1000 degree celsius (auto / manual), readout : 7 digits led (3 digits for temp. and 4 digits for cond./tds), printer interface for 80 column d.m. printer with minimum one year warranty