Get complete information related to latest Tester Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tester Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tester Repair Tenders.
Tender For supply of refilling of oxygen cylinder , refilling of acetylene cylinder , repair of fuel injector tester , repair of portable welding machine , repair of gds 18 e impact wrench bosch
Tender For service of vacuum filter and supply of its spares and cluster nozzle - vacuum filter spares & service, s.s. screen having 625 holes/sq. inches. (salem make) (minimum weight 1.2 kg. each screen), brass zigzag strips (2 long), rubber hose pipe (2 " x 24"), mud scrapper 5"x10 mm x 6 ply (dunlop make) for 8 x 16 vaccum filter, araldite 1.8 kg. pack, m-seal 1 kg. packing (pidilite make), a) brass end strip, b) s.s. end strip, copper revit round head 5mm x 12mm, copper revit rounf head 5mm x 15mm, copper revit rounf head 5mm x 18mm, soft lead 8 mm wire, brass tube plate for 8x16 vaccum filter, ss electrode (no 12) 2.5 mm thick, roller for mud conveyor belt, ss clamp for binding rubber hose pipe 2 1/4"x24", s s bolt 1/4"x3/4", s.s. channel 16 long, monarch brass nozzles, m s shocket for monarch brass nozzles, junction box (s.s. sheet) from 3mm thick plate heavy duty, s.s. nipple for decking plate (as per sample), s.s. decking plate for 8x16 (as per our site vacuum filter), s. s. binding strip 3/4" x 2-1/4, s. s. pipe 1.5mm thick, size= 1/2 x 46 , s. s. pipe 1.5mm thick, size= 1/2" x 65 , s. s. pipe 1.5mm thick, size= 1/2" x 16.5 , s. s. pipe 1.5mm thick, size= 1/2 x 28 , s. s. pipe 1.5mm thick, size= 3/4 x 7, s. s. pipe 1.5mm thick, size= 3/4 x 6.5, s. s. pipe 1.5mm thick, size= 3/4 x 10, round head s.s. screw " x 3/4", s.s. electrodes (no. 10) thikness 3.15 mm, vacuum filter vacuum disc plate (brass/gun matel) complete set (left & right), s.s. gate valve (screw type) 2 size, s.s. electrodes (no. 8) 4mm size, servicing of vacuum filter, after dismantling of s.s. screens of vacuum filter no. 1, 2 & 3, cleaning of decking plates, conducting hydraulic testing of five way fitting connections and giving satisfactory leak proof trials of same and thereafter refitting of all the dismantled s.s. screens complete in all respect, fitting of new damaged five way fittings (complete with welding etc.) of vacuum filter no. 1, 2 & 3 and thereafter conducting satisfactory leak proof trials. (5 way fitting), replacement of damaged decking plate nipples of vacuum filter no. 1, 2 & 3 and welding with five ways fitting, thereafter conducting satisfactory leak proof trials., replacement of damaged end strips of vacuum filter with new strips complete in all respect and thereafter conducting satisfactory leak proof trials. half filter, replacement of damaged end strips of vacuum filter no. 3 with new strips complete in all respect and thereafter conducting satisfactory leak proof trials. full filter, replacement of damaged brass/s.s. channels (16 ft. lengthl) of vacuum filter with new s.s/ brass channels complete in all respect, replacement of damaged decking plate of vacuum filter with new decking plate complete in all respect., dismantling & fitting both end s.s. tube of filter with vacuum distribution plate in filter and satisfactory trial., grinding of tunion valve plate with bear plate of vacuum filter and sucessful trial at minimum of 450mm of vacuum at junction with rotation of drum., vacuum genration up to 400mm at vacuum disc (including testing of pipe line to be made), keeping in the condition of genration of vacuum at vacuum pump was more then 625mm., repair of 8 point lubricator of vacuum filters (including cost of all un-serviceable parts), 3/8" bsp, non return valve, angle type, working pressure 21 kg./sq.cm. (as per sample), m.s. plug 3/8", m.s. plug 1/2", m.s. tee 3/8", m.s. elbow 3/8", supply of five way clusterwith nozzlefor mill mist colling system (complete in all respect) as per existingscope of workits including five way fitting branch line and nozzle.1- material- thermoplastic equivalent2- guarantee- one full crushing season, spray nozzle for mist cooling system
Tender For supply of diagnosis break testerrepair and maintenance of vehicels , repair of pipe line als , rotter coil repaired , repair of pressure pipe line tata , brush box repaired
Tender For providing of testing service for on-board /commissioned equipment/ instrument related to plant - civil; crack width measurement in reinforcement concrete structures, leak testing facility; any other government approved labs /service providers
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; sl no 1 installation of dummy flange of size 1200mm to 1400 mm in rcb isolation damper lines for testing of dampers which involves unbolting, removal of r..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; sl no 2 carrying out pneumatic leak test of rcb isolation dampers of size 1200mm to1400mm which involves removal of duct section/ manhole for accessing of..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; sl no 3 carrying out in-situ service of rcb isolation dampers of size 1200mm to1400mm which involves replacement of gaskets/seals/adjusting disc travel; a..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; sl no 4 removal of dummy flange of size 1200mm to 1400mm in rcb isolation damper lines after testing of dampers which involves unbolting, removal of dummy..,repair, main
Tender For supply of as per boq itmes e e - supply of 2.00 ton hi wall split air conditioner, inverter type, 5-star eneray rated as per latest 2026 bee guidelines, havingiseer value ranging from 5.6 with cooling6.25 kw and rated power input for cooling 1500-1650 w complete in all respects theac shall be provided with high effciency inverter rotary compressor with acoutic jacket, factory charged with eco fiendly r-32refrigerent and 100% copper condenser coil with protecive anti-corrosion coating (e.g hydrophillic blue/ shieldblu+). the unitshall have airflow of approximately 900-1050 cfm (wet), indoor unit noise level around 38-43 db (low/ medium), and shall besuitable for stabilizer free operation on wide voltage range of 100-290 v. the ac shall be equipped with pm 2.5 filter, anti dustfilter and anti microbial filters for improved indoor air quality, along with smart features such as ai modes (true ai/ i sence) andconvenience features including hidden display, auto restart, self diagnosis and 4 way swing. the item shall include supply ofindoor and outdoor units, wall mounted stand for outdoor unit, standared copper piping with insulation, drain piping,interconnecting elcetical wiring, vacuum evacuation, leak testing, complete installation, testing and commissiong, all as permanufacture's specifications , supply of 1.5 ton hi wall split air conditioner, inverter type, 5-star eneray rated as per latest 2026 bee guidelines, having iseer value ranging from 5.6 with cooling 5-5.2 kw and rated power input for cooling 1200-1250 w w complete in all response, the ac shall be provided with high effciency inverter rotary compressor with acoutic jacket, factory charged with eco fiendly r-32 refrigerent and 100% copper condenser coil with protecive anti-corrosion coating (e.g hydrophillic blue/ shieldblu+). the unit shall have airflow of approximately 650-760 cfm (wet), indoor unit noise level around 38-43 db (low/ medium), and shall be suitable for stabilizer free operation on wide voltage range of 100-290 v. the ac shall be equipped with pm 2.5 filter, anti dust filter and anti microbial filters for improved indoor air quality, along with smart features such as al modes (true al/ i sence) and convenience features including hidden display, auto restart, self diagnosis and 4 way swing. the item shall include supply of indoor and outdoor units, wall mounted stand for outdoor unit, standared copper piping with insulation, drain piping, interconnecting elcetical wiring, all as per manufacture's specifications., supply of 1200 mm sweep bldc ceiling fan, complete with brushless dc motor suitable for operation on 230 volts, 50 hz, single phase ac supply, having minimum air delivery 210 cmm, power consumption not exceeding 35 watts at full speed, service value minimum 6.5 m³/min/w, provided with electronic remote regulator (5 speed) with timer and sleep mode, aerodynamic aluminium blades (3 nos), copper wound motor, double ball bearing, in-built surge protection up to 4 kv, suitable for inverter operation with wide operating voltage range 140-285 volts, complete with 250 mm down rod, canopy, shackle assembly, safety pin, nut bolts, rubber bush, ceiling hook and connecting to existing point wiring including testing and commissioning complete all as specified and directed., supply of 25 litre capacity electric storage water heater (geyser), vertical type, suitable for operation on 230 volts, 50 hz, single phase ac supply, complete with 2000 watts copper/incoloy heating element, adjustable thermostat (30°c to 75°c), automatic thermal cut-out, multi-function safety valve, non-return valve, pressure relief valve, glass lined / vitreous enamel coated inner tank suitable for working pressure minimum 8 bar, high density puf insulation, rust proof abs/crca powder coated outer body, ipx4 protection, isi marked conforming to is 2082, complete with wall mounting brackets, anchor fasteners, inlet & outlet connections, connecting to existing cold and hot water pipe