Tender For purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat a
Tender For corrigendum : supply of dvr spares for ms bhel make generator - module 69203nb1aa un0662av1 32 channel digital input output card item number -1 , module 69203sv1aa un0665av1 32 channel alarm indication card item number -2 , module 69203yb1aa uns 2661av1command input item number -3 , test point module ce69138840 un0094a item number -4 , pulse final stage assembly ce69138930 un0097a item number -5 , memory card 69203yv1aa ct370av1 old code ed7470400389 item number -6 , potential separating stage card ce69136570 un0099a old code cn9090365702 item number -7 , module 48v dc 69203ib1ba nc4661av2 16 channel binary input output item number -8 , module 69203ob1aa unc4662av1 16 channel binary output item number -9 , cont 500vac or 600vdc 4no and 4nc coil 220vdc item number -10 , surge suppressor diode 150v or 250v dc 3tx74023jy1 item number -11 , switch rotary 16p 2pos 16a and 440v item number -12 , transformer 575v to 110v 200va ynyn0 z 4percent 4kv 50hz 1minute insulation b item number -13 , lamp pi green with cluster led lens assembly item number -14 , switch pb selector act black 3sb50002ab 01 item number -15 , switch rotary 4 pole 4 position 6amp and 440v item number -16 , interface module rm 09 04b item number -17 , receptacle 22 pole ms3102r 28 11 p item number -18 , power term fix arrgt item number -19 , disconnecting and testing type clip on terminal item number -20 , clip on switch gear terminal size 6 table 1 item number -21 , numeric type 3 phase over current relay with lcd display ct input 1a auxiliary supply 220v plus10 percent minus15 percent vac item number -22 , transformer ct winding primary 5va and 1a item number - 23 , relay lacng 220vdc 7no and 7nc psu14 2x item number -24 , transformer dry 4 kva 3phase 575v to 165v dyn11 z 4 percent 4kv 50hz for 1minute item number -25 , transformer 4kva 3phase ynyn0 415 to 165v item number -26 , transformer control 100va 220v to 240v and 220v item number -27 , ct single core wound primary ratio 5a to 1a rating 20va alt code sa0653941706 item number -28 , temperature surveillance u nit apr103 item number -29
Tender For supply of frequency converter drive, atv 71, 30 kw, input - 3 ac, 380-450 v, with graphical display terminal, , frequency converter drive input voltage 415v, 3 phase, 50hz, frequency range 0-1000hz, input current 40
Tender For supply of automatic weather station , software with license , peripheral equipment , data terminal-display with printer , installation materials and accessories , system cables-cable assemblies-connector , on board spares , special tools and test equipment , documentation , service of engineer , training