Tender For corrigendum : supply of e4253001 for numerical relays for ntpc lara project - e4253001 numerical relays crp 01-sg4935107006- numerical main-1 generator protection relay as per it-01 of ann-1 , 02-sg4935107014-accessories for sef _and_ ref as per it-02 of ann-1 , 03-sg4935107022- numerical main-2 generator protection relay as per it-03 of ann-1 , 04-sg4935107030-numerical transformer differential _3 wdg_ protection relay as per it-04 of ann-1 , 05-sg4935107049-numerical overall differential protection relay as per it-05 of ann-1 , 06-sg4935107057-numerical overcurrent _and_ ref protection relay as per it-06 of ann-1 , 07- sg4935107065-metrosil as per it-07 of ann-1 , 08- sg4935107073-stabilising resistor _0-5k_ as per it-08 of ann-1 , 09-sg4935107081-ethernet switch as per it-09 of ann-1 , 10-sg4935117001-numerical main-1 line distance protection relay _process bus_ as per it-10 of ann-1 , 11-sg4935117010-numerical main-2 line distance protection relay _process bus_ as per it-11 of ann-1 , 12-sg4935117028-numerical main-1 line differential protection relay _process bus_ as per it-12 of ann-1 , 13-sg4935117044-numerical main-2 line differential protection relay _process bus_ as per it-13 of ann-1 , 14-sg4935117117-numerical transformer differential _3 wdg_ protection relay _process bus_ as per it-14 of ann-1 , 15- sg4935117125-numerical overcurrent _and_ ref protection relay _process bus_ as per it-15 of ann-1 , 16-sg4935117133-numerical islanding relay _process bus_ as per it-16 of ann-1 , 17- sg4935117141-numerical lbb protection relay _process bus_ as per it-17 of ann-1 , 18- sg4935117150-numerical teed protection relay _process bus_ as per it-18 of ann-1 , 19- sg4935117168-metrosil as per it-19 of ann-1. , 20- sg4935117176-stabilising resistor _0-5k_ as per it-20 of ann-1 , 21-sg4935117184-numerical busbar protection process bus _new switchyard in present scope_ as per it-21 of ann-1 uom-set , 22- sg4935117192-bay control unit _process bus_ as per it-22 of ann-1 , 23-sg4935117206-panel along with merging unit _and_ switchgear control unit _process bus_ as per it-23 of ann-1 uom-set , 24- sg4935117214-ethernet switch _process bus_ as per it-24 of ann-1 , 25-sg4935117222- gateway_slash_networking panel as per it-25 of ann1 , 26-sg4935117230-ows _ccr_ as per it-26 of ann-1 uom-set , 27-sg4935117397-ews _cer_plus_crp_plus_ccr_ as per it-27 of ann-1 uom-set , 28-sg4935117249-laptop _scr_plus_ex_ as per it-28 of ann-1 , 29-sg4935117400-a4 printer _cer_plus_crp_plus_ccr_ as per it-29 of ann-1 , 30- sg4935117257-ows _scr_plus_ex_ as per it-30 of ann-1 uom-set , 31-sg4935117265-ews _scr_plus_ex_ as per it31 of ann-1 uom-set , 32-sg4935117273-a3 printer _scr_plus_ex_ as per it-32 of ann-1 , 33-sg4935117281- a4 printer _scr_plus_ex_ as per it-33 of ann-1 , 34- sg4935117370-dot matrix printer _scr_plus_ex_ as per it-34 of ann-1 , 35-sg4935117290-laptop _scr_plus_ex_ as per it-35 of ann-1 , 36-sg4935117303- 80 inch rear projection lvs as per it-36 of ann-1 uomset , 37-sg4935117311-inverter as per it-37 of ann-1 uom-set , 38-sg4935117320-network firewall as per it-38 of ann-1 uom-set , 39-sg4935114002-fo cable _in mtrs_ as per it-39 of ann-1 uom-meters , 40- sg4935117338-control room furniture as per it-40 of ann-1 uom-set , 41-sg4935117346-sas spares as per it-41 of ann-1 uom-set , 42-sg4935117354-training as per it-42 of ann-1 uom-set , 43-sg4935117389-amc as per it-43 of ann-1 uom-set
Tender For supply of providing and fixing of lightning conductor finial. , jointing copper or g.i. tape with another copper or g i tape , providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall , providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess , repairing rewinding of 1 hp capacity centrifugal pump , repairing rewinding of 2 hp capacity centrifugal pump , repairing rewinding of 3 hp capacity centrifugal pump set , repairin rewinding of 5 hp capacity centrifugal pump set , repairing rewinding of 1.5 hp capacity submersible pumpset , repairing rewinding of 2 hp capacity submersible pumpset , repairing rewinding of 3 hp capacity submersible pumpset , repairing rewinding of 5 hp capacity submersible pumpset , sitc of submersible pumpset of 2 hp water filled , sitc of submersible pumpset of 4 hp water filled , lifting and lowing of submersible or borewell pump upto 5 hp alongwith gi pipe , lifting and lowing of submersible or borewell pump upto 5 hp alongwith hdpe pipe , repairing rewinding of 2 hp sump pump set , repairing rewinding of 3 hp sump pump set , repairing rewinding of 5 hp sump pump , replacement of faulty foot valve of size 40 mm dia , replacement of faulty foot valve of size 50 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 20 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 40 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 50 mm dia , replacement of nrv with new nrv made up of brass of size 40 mm dia , replacement of nrv with new nrv made up of brass of size 50 mm dia , supplying and fixing 20 mm dia b class medium g.i pipe , supplying and fixing 40 mm dia b class medium g.i pipe , supplying and fixing 50 mm dia b class medium g.i pipe , supplying and fixing 20 mm dia heavy duty upvc pipe , supplying and fixing 40 mm dia heavy duty upvc pipe , supplying and fixing 50 mm dia heavy duty upvc pipe , replacement 3 pole power contactors type mnx 12 , replacement 3 pole power contactors type mnx22 , replacement of mounting add on aux. contact block suitable for 9 a to 30 a , replacement of thermaloverloadrelay suitable for mnx contactor range from 0.2 a to 23 a , supplying of 3 x 2.5 sq. mm aluminum conductor cable of 1.1kv grade , supplying of 4 x 16 sq. mm aluminum conductor cable of 1.1kv grade , supplying of 3.5 x 35 sq. mm aluminum conductor cable of 1.1kv grade , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size upto 35 sq.mm on cable tray , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm on cable tray , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm on cable tray , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size //bid details 3 / 138 upto 35 sq. mm on wall surface , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm on wall surface , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm on wall surface , s and m end termination with brass compression gland and aluminium lugs for 2 x 6 sq.mm al cable. , s and
Tender For supply of providing and fixing of lightning conductor finial. , jointing copper or g.i. tape with another copper or g i tape , providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall , providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess , repairing rewinding of 1 hp capacity centrifugal pump , repairing rewinding of 2 hp capacity centrifugal pump , repairing rewinding of 3 hp capacity centrifugal pump set , repairin rewinding of 5 hp capacity centrifugal pump set , repairing rewinding of 1.5 hp capacity submersible pumpset , repairing rewinding of 2 hp capacity submersible pumpset , repairing rewinding of 3 hp capacity submersible pumpset , repairing rewinding of 5 hp capacity submersible pumpset , sitc of submersible pumpset of 2 hp water filled , sitc of submersible pumpset of 4 hp water filled , lifting and lowing of submersible or borewell pump upto 5 hp alongwith gi pipe , lifting and lowing of submersible or borewell pump upto 5 hp alongwith hdpe pipe , repairing rewinding of 2 hp sump pump set , repairing rewinding of 3 hp sump pump set , repairing rewinding of 5 hp sump pump , replacement of faulty foot valve of size 40 mm dia , replacement of faulty foot valve of size 50 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 20 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 40 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 50 mm dia , replacement of nrv with new nrv made up of brass of size 40 mm dia , replacement of nrv with new nrv made up of brass of size 50 mm dia , supplying and fixing 20 mm dia b class medium g.i pipe , supplying and fixing 40 mm dia b class medium g.i pipe , supplying and fixing 50 mm dia b class medium g.i pipe , supplying and fixing 20 mm dia heavy duty upvc pipe , supplying and fixing 40 mm dia heavy duty upvc pipe , supplying and fixing 50 mm dia heavy duty upvc pipe , replacement 3 pole power contactors type mnx 12 , replacement 3 pole power contactors type mnx22 , replacement of mounting add on aux. contact block suitable for 9 a to 30 a , replacement of thermaloverloadrelay suitable for mnx contactor range from 0.2 a to 23 a , supplying of 3 x 2.5 sq. mm aluminum conductor cable of 1.1kv grade , supplying of 4 x 16 sq. mm aluminum conductor cable of 1.1kv grade , supplying of 3.5 x 35 sq. mm aluminum conductor cable of 1.1kv grade , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size upto 35 sq.mm on cable tray , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm on cable tray , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm on cable tray , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size //bid details 3 / 138 upto 35 sq. mm on wall surface , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm on wall surface , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm on wall surface , s and m end termination with brass compression gland and aluminium lugs for 2 x 6 sq.mm al cable. , s and