Get complete information related to latest Thermal Scanner Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Thermal Scanner Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Thermal Scanner Tenders.
Tender For (thermalscanner) supply and commissioning of thermal imaging camera conforming to rdso spec. i/spc/ohe/tips/1031 dec-2023 or latest each unit consisting of (1) infrared thermal imaging camera with integrated digital camera,voice recording with headphone, auto cold and hot spot recognition, data downloading and printing facility, battery with mains charger, carry case and calibration certificate (2) camera optics should include suitable hfov and vfox suitable for measurement, imaging, monitoring and storing (3) fpa of more than 320 x 240 pixel. (4) telephoto lens 9 deg. x 7 deg. lens of better. (5) camera suitable for measurement of temperatures ranging from -20 to +500 deg. c or better. (6) camera shall have other features detailed in rdso spec. to features similar to model 875-2ipart no. 05630875 v3 g1 of make- testo, fluke, flir, bosch, infratecgmbh, toshiniwal or similer, [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of thermalscanner-thermal imaging camera with object temperature range: -20 degree c to 400 degree c (-4 degree f to 752 degree f) resolution: 160 x 120 pixels (19,200 pixels total)connectivity: wi-fi enabled, battery type: rechargeable built-in lithium-ion battery operating time: up to 4 hours, thermal sensitivity of 0.06 degree celsius, image detector type uncooled focal plane array (fpa)vox/asi/bst/silicon [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : this is regarding the procurement of five (05) thermalscanners for deployment at designated points of entry (poes) under the pradhan mantri ayushman bharat health infrastructure mission (pm-abhim).
Tender For supply of multi process control trainer setup for instrumentation engineering lab under mhrd scheme - purchase of multiprocess control trainer setup for instrumentation engineering lab under mhrd scheme - multiprocess control trainer set up, multiprocess control trainer set up - specifications:- setup must contain flow, pressure, level, temperature loops also derived loops like cascade and feedforward loops. temperature loop must be independent. setups consist of a circulating closed loop water plant or circulating water system including control valve, tanks, independent pumps and necessary valves including bypass valves and rotameters. using this we can be able to do flow control loop with pid,level control loop with pid,and pressure control pid, as independent experiments.the setup must include the following:1.one linear characteristics diaphragm operated control valve with 15mm stroke 1/2-inch size, type: high-capacity globe seat leakage class (as per ansi/fci 70.2).2.measuring tank with volumetric measurement scale and 1000mm level, in of 25 ltr capacity. sump tank min of 40 ltr capacity. all tanks made of ss304, with sight glass, and finished with mat steel finish.3.2 no s smart dp transmitter for flow and level measurement with hart protocol, display and keys integrated for calibration,0-1000mmh2o measurement range,0.01% accuracy, international iso certified ce approved make,24v supply,4-20ma output, loop powered.4,1nos of magnetic flowmeter with display and keys integrated for calibration,0-2000lph measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, international iso certified ce approved make,24v supply,4-20ma output to measure flow as a independent loop.5,. smart pressure transmitter and temperature transmitters with hart protocol, display and keys integrated for calibration, pressure transmitter 0-10bar measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, temperature transmitter 0-250 rtd type international iso certified ce approved make,24v supply,4-20ma output, loop powered.6, pressure tank of 24 liters with necessary valves for pressure loop.7.1nos orifice plate (ss304) and assembly grade with flange 1/2-inch size for flow measurement.8.2 nos pumps 0.5hp, ss centrifugal pump, minimum 1-inch pipeline of ss or high-pressure withstanding plastic with plastic welding.9. rotameters 2nos 1 inch size flow: 200-2000 l/h,ss thread, clear acrylic type.10, plc control station with 4 analogue inputs and one analogue output with necessary digital inputs and outputs to operate all loops directly from panel side.plc must have ethernet connectivity with supported protocols profinet and modbus tcpip.11.required all pneumatic components to full fill the process loops such as fr,needle valves etc.12,i to p converter 4-20ma to 3-15psi with 1/4" process connection with proper copper copper tubing.13, loop including flow pid control, level pid control, pressure pid control, cascade control (level flow), ratio control (flow flow).14.all loops can be operated using a scada system and independent pushbutton control includes trend of all analogue signals and pid tuning. scada direct profinet connectivity to plc and computer with intel i5 processor, 8gb ddr3 ram,1tb sata hdd,licenced windows 11 professional.15, required a standalone software application that must be installed on pc in which it can used to control and monitor all the functions used in scada. the application must contain process parameter trend graph plot for to study about process loops.16.the whole system setup must be in ms powder coated standalone mobile table with lockable castor wheels. all the components used be industrial. copper tubing for air connection, pressure gauges 4inches 3nos, electrical wiring connection to be flexible for to connect field devices. panel with switches, indicator, test points with banana connectors as required, multistrand wire with proper insulated lugs, ferruling & neat wire dressing & clam
Tender For ece lab items dept use - eliminator transformer (step-down) kitinput - 220v - 240v ac, 50 hz, output-2v to 12v dc, 0-2 a ripple: 5mv, strain gauge trainer kitmetal foil strain gauge mounted on beam/cantilever strain measurement under applied load wheatstone bridge arrangementsignal conditioning and amplification circuitinstrumentation amplifiers, 3 digit display of strain / output voltage zero and gain adjustment controlsprovision for applying calibrated loads regulated power supply, 230 v ac, 50 hz table-top trainer with labeled paneltest points to measure the signalsbuilt in power supplies and wooden closed cabinet supplied with patch cords and experiment manual, temperature measurement kitsensors: rtd (pt-100), thermocouple (fe-k/j-type), and/or thermistor (ntc).display: 3 digit led/lcd digital display (typically 200mv fsd). temperature source: portable water kettle or heater block.signal conditioning: on-board circuitry for amplification, linearization, and cold junction compensation.test points: multiple 2mm/4mm banana sockets for monitoring input/output signals.power supply: 230v ac, 50hz, single-phase.accessories: includes a glass thermometer, ntc thermistor probe 10k, k-type thermocouple probe, patch cords, and instruction manual., sim reader trainer kitsim compatibility supports 2g 3g 4g lte sim cards,sim reader mode: reading writing gsm sim card data, imsi, ki codes, phonebook interface usb 2.0 or rs 232 serial port for pc communication.clock frequencies: selectable frequencies 3.579 mhz, 7.159 mhz, 14.318 mhz for sim card operation.power supply: onboard smps 12v 2a or 5v dc with overload protection. hardware components:6-pin or 8 pin sim card socket.led indicators for power, sim reset, and data activity.optional lcd 128x64 and keypad 20 keys for standalone operation. software tools support for at commands gsm etsi 07.0707.05, sim manager utilities, and data logger functionality. common trainer kit featuresfault simulation ability to create faults e.g., sim not detected, vcc failure for troubleshooting.test points: multiple test points e.g., 55 nos for observing signals sim rst, clk, i o via oscilloscope.construction tested glass epoxy pcb, often housed in a study educational case., dual output regulated dc variable power supplydual output regulated power supply- input voltage: 230v/50hzac- output voltage: (0 30v)dc- output current: (0 2a)dc- protection circuit: over voltage and over current protection, short-circuit protection- high efficiency: greater than 85%- low ripple and noise: less than 50 mv, lvdt sensor trainer kitac mains power supply : 230v 10%, 50hzfixed regulated dc power supply : +5v, 12v 500matransducer : lvdtlvdt displacement : 20mm (40mm total)displacement scale : linear 20mmdisplacement display (mm) : red color 3 digit led displayexcitation frequency : 4khzexcitation voltage : ac variable 5v, dc digital voltmeter - 3 digit led/lcd display, measurement range: 0 20 v dc, accuracy: class 0.5( 0.5 % full-scale), dc ammeter digital - 3 digit led/lcd display, measurement range: 0 5 a dc, accuracy: class 0.5 ( 0.5 % full-scale)
Tender For thermalscanner cum thermal imaging camera with following features 1) object temperature range: -20 degree c to 400 degree c (-4 degree f to 752 degree f) 2) resolution: 160 x 120 pixels (19,200 pixels total) 3) connectivity: wi-fi enabled, 4) battery type: rechargeable built-in lithium ion battery operating time: up to 4 hours. 5) thermal sensitivity of 0.06 degree celsius, image detector type uncooled focal plane array (fpa) 6) make : vox/asi thermal /bst/ agile flir - c5 /fluke. 7) the supply must be accompany with oem calibration certificate traceable to nabl lab. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of thermalscanner-thermal imaging camera as per specification annexutre-i attached. make: : flir - c5 wifi, meco, motwane, fluke , rishab , testo, tipl, kusam-meco or similar. [ warranty period: 30 months after the date of delivery ]