Get complete information related to latest Thermal Sensor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Thermal Sensor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Thermal Sensor Tenders.
Tender For implementation of cyber security measures in scada system for 25kv & 2x25kv single phase 50hz ac traction power supply over kr line of waltair division.
Tender For supply, installation, testing and commissioning of aerosol based fire suppression system in emu mc and tc as per the technical requirement specified in annexure -g 1 of rdso specification rdso/pe/spec/ac/0192-2018 (rev.1) or rcf edml 0184 (type-i, correction -1) or latest. one set of aerosol unit consist of three items - (i) fire extinguishing generator 100 gms (1 nos.), (ii) thermalsensor (1 nos.) , (iii) mounting bracket with associated hardware(1 nos.) note: action temperature in sn.04 of specs. no. rdso/pe/spec/ac/0192-2018 (rev-1) annexure-g1 and rcf edml 0184 (type-1, correction-1) to be read as 68-72 degrees celsius as per rdso letter no. el/7.1.108/sbc/main dtd. 06.08.25 [ warranty period: 30 months after the date of delivery ] ]
Tender For providing cctv system with ai features cameras for the security measures in the premises of honorable chief minister residence cauvery and home office krishna at k.k.road, bengaluru.
Tender For supply of condensed aerosol based fire detection & suppression system & associated accessories for three phase memu tc, as per drawing: edml0184,type-i.corr-1, packing instruction: as per standard packing.one set will consist of - (aerosol canister - 02 nos.. sensing actuation mechanism - 02 no.. installation bracket - 02 no.) the setting of the thermalsensor should be in accordance with the latest railway board guidelines. (remarks - 1) each set of condensed aerosolbased suppression system comprissing of (i) fire extinguishing generator of minimum 100 gms (02 nos) (ii) thermalsensor (02nos) (iii) mounting brackets with associated hardware (02 nos) as per drawing no.edml0184. 2) the setting of the thermalsensor should be in accordance with the latest railway board guidelines.) [ warranty period: 30 months after the date of delivery ]
Tender For supply of condensed aerosol based fire detection & suppression system & associated accessories for three phase memu dmc, as per drawing: edml0184,type-i.corr-1, packing instruction: as per standard packing.one set will consist of - (aerosol canister - 08 nos.. sensing actuation mechanism - 08 no.. installation bracket - 08 no.) the setting of the thermalsensor should be in accordance with the latest railway board guidelines. (remarks - 1) each set of condensed aerosol based suppression system comprissing of (i) fire extinguishing generator of minimum 100 gms (08 nos) (ii) thermalsensor (08 nos) (iii) mounting brackets with associated hardware (08 nos) as per drawing no.edml0184, 2) the setting of the thermalsensor should be in accordance with the latest railway board guidelines.) [ warranty period: 30 months after the date of delivery ]
Tender For tender for supply of sitc and maintenance of addressable fire alarm and detection system at uco bank - supplying , installing , testing and commissioning approved make microprocessor based multi-loop , networkable addressable 02 loop fire alarm control panel with minimum 10 inch 1024x600 resolution lcd with touch capability , including audible and visible feedback , backlit by a long life , solid-state lcd. it shall also include a full qwerty-style keypad on the color , touchscreen display. the display shall have the ability to scroll events by type (i.e. fire alarm , supervisory alarm , trouble , etc) using the touchscreen with customizable buttons , 10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops. , supplying , installing , testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the fire panel cpu for operation. modbus over tcp/ip , meets ul 864 , 10th edition requirements , supports two modbus masters & monitored 10 cpu nodes . failure of fire panel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed , the mimic annunciator for the fire alarm control panels (facp). this provides the facp with remote , serially-connected display. a five inch touchscreen display provides system status , point information , and event counters. the display shows two events simultaneously , and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge , silence , reset and drill. , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermalsensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved. , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermalsensor with photoelectric signal in an effort to react hastily in the event of a fire situation. , supplying , installing , testing and commissioning approved make addressable manual call point ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved. , supplying , installing , testing and commi
Tender For bid to ras bid to ras bid to ras corrigendum : supply of procurement of laboratory equipment c c -digital infiltrometer , digital flow meter , digital tensiometer , multi slot divisor , coshocton wheel silt sampler , digital pan evaporimeter , surface velocity radar , hewkeye mini eco sounder , portable suspended solid analyzer with accessories , bed load sampler , parshall flume , h flume , rainfall simulator , sieve shaker with sieves , spectro radiometer , lysimeter , digital et gauge , portable cod colorimeter meter , bod analyser with mst magnetic stirrer , ammonia ion-selective electrode , free residual chlorine kit , cod digester , kjeldahl instrument , bouyoucos hydrometer , tdr soil moisture sensor with access tube , remote sensing drone with multi spectral and thermalsensors