Tender For corrigendum : work of supply and application of spraythermalinsulation for turbines & turbine related various piping and valves of 250 mw units 3&4 of stps on as & when required basis.
Tender For supply of 8 point 5 tr air cooled ductable split airconditioner equipped with scroll or rotary compressor expansion valve for optimal refrigerant feed galvanized constuction finished in powder coat , supply and installation of gss ducting fabricated as per is 655 standards will all accessories 22 gauge , supply and installation of gss ducting fabricated as per is 655 standards will all accessories 24 gauge , supply and fixing of canvass connections for connecting the ducting and ductable indoor units , refrigerant piping interconnecting condensing unit and indoor units using 11 by 8 inch 5 by 8 inch copper pipes and suction lines duly insulated with 9 mm thick tubular foam , drain piping using hard pvc pipes from indoor units to the nearest drain point for each indoor unit 32mm , pvc insulated copper un armoured cable 3 core 1 point 5 sqmm , supply and fixing of aluminium grill or diffusers , ms color dampers , itc of ac units including nitrogen pressure testing vaccumisation of the units initial refrigerant charge along with lifting and shifting of machines and other ancillary works , ms angle work for out door units , ms angle work for indoor units duct supports etc , timer for each machine , thermalinsulation with 13 mm closed cell nitrile rubber , accoustic insulation with 10 mm thick open cell nitrile rubber , comprehensive amc charges for ducted ac units after completion of warranty first year , comprehensive amc charges for ducted ac unitsafter completion of warranty second year , comprehensive amc charges for ducted ac units after completion of warranty third year , comprehensive amc charges for ducted ac units after completion of warranty fourth year , comprehensive amc charges for ducted ac units after completion of warranty fifth year
Tender For supply and application of insulation materials on pipe, equipment for part a and part b as per standard specification by providing all required materials in connection with the composite work for setting upof hpg-2, butene-1 and psa units atlepetkata - legends / notes for insulation workstypes of insulation : ih = insulation for heat conservation it = insulation for steam traced lines is = insulation for personal safety ic = cold insulation for anti-condensation ie = insulation for electrically traced lines ij = insulation for jacketed lines ik = insulation for dual insulated lines basic line surface materials : cs = carbon steel (including lt carbon steel), as = alloy steel, ss = stainless steelnotes :1. for insulation type it,tracer size and tracer numbers shall be as per specification.2. insulation thickness for ic where insulation material is poly urethane foam (puf) / poly isocyanurate (pic) + cellular glass includes outer layer of 50mm of cellular glass and inner layer of balance thickness of puf/pic.3. insulation for ie consists of inner layer of rockwool and outer layer of puf / pic. the thicknesses have been specified as thk(i) and thk(o) for inner and outer layers respectively., part a, hot insulation (units)providing thermalinsulation including supply of all insulating and ancillary materials, vapour barrier, weather protective coverings, consumables and other necessary materials , testing of materials as required, including transportation of materials to work site, duly inspected by 3rd party inspector(llyods/bv/dnv or any other client approved party) at manufacturers shop & sample check/inspection at site by eil construction inspector, applying insulation on surfaces as specified including all preparatory work there on, binding, tying, lacing, stitching and/or otherwise securing , finishing with sheet cladding as per spec. , providing bolts, rivets, and self tapping screws wherever specified , providing inspection windows, end seals for flanges etc., colour coding and identification. providing steel scaffolding, all tools , tackles , equipments etc. , labour, supervision and completing the work in all respect, at all heights as per drawings , specifications and instructions of engineer-in-charge. (refer legend for applicable eil specification), insulation type : ih ; surface material : cs & as ; operating temp. range : upto 125 (deg c) ; insulation material : rockwool, pipes, nb 00.75 inches; thickness 25 mm, nb 01.00 inches; thickness 25 mm, nb 01.50 inches; thickness 25 mm, nb 02.00 inches; thickness 25 mm, nb 03.00 inches; thickness 25 mm, nb 04.00 inches; thickness 25 mm, nb 06.00 inches; thickness 25 mm, blind flange assemblies, nb 00.75 inches; thickness 25 mm, nb 02.00 inches; thickness 25 mm, valve assemblies, nb 00.75 inches; thickness 25 mm, insulation type : ih ; surface material : cs & as ; operating temp. range : 126 (deg c) to 350 (deg c) ; insulation material : rockwool, pipes, nb 00.50 inches; thickness 25 mm, nb 00.50 inches; thickness 40 mm, nb 00.75 inches; thickness 25 mm, nb 00.75 inches; thickness 40 mm, nb 00.75 inches; thickness 50 mm, nb 01.00 inches; thickness 25 mm, nb 01.00 inches; thickness 40 mm, nb 01.00 inches; thickness 50 mm, nb 01.50 inches; thickness 25 mm, nb 01.50 inches; thickness 40 mm, nb 01.50 inches; thickness 50 mm, nb 02.00 inches; thickness 25 mm, nb 02.00 inches; thickness 40 mm, nb 02.00 inches; thickness 50 mm, nb 02.00 inches; thickness 65 mm, nb 03.00 inches; thickness 25 mm, nb 03.00 inches; thickness 40 mm, nb 03.00 inches; thickness 50 mm, nb 03.00 inches; thickness 65 mm, nb 04.00 inches; thickness 25 mm, nb 04.00 inches; thickness 40 mm, nb 04.00 inches; thickness 65 mm, nb 06.00 inches; thickness 40 mm, nb 06.00 inches; thickness 65 mm, flange assemblies, nb 01.50 inches; thickness 25 mm, nb 01.50 inches; thickness 50 mm, nb 02.00 inches; thickness 25 mm, nb 02.00 inches; thickness 40 mm, nb 02.00 inches; thickness 50 mm, nb 03.00 inches; thickn
Tender For providing of custom bid for services - preparation of 14 nos steam boilers for their annual inspection after through cleaning and maintenence and thermalinsulation bare inspection for steam boiler no mr13665 terms and conditions scope of work and specification
Tender For corrigendum : work of application of thermalinsulation & aluminum cladding of various ducts, piping, valves and water wall for boiler unit 3 & 4 on as & when required basis.