Web Analytics Made Easy - StatCounter

Thermistor Relay Tenders

Get complete information related to latest Thermistor Relay Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Thermistor Relay Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Thermistor Relay Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45296673 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For replacement of defective s&t cables, decayed/worn-out location boxes, overaged track relays and other equipments in section of dste/kqr & aste/gmo.

CTN :45213467 Due date: 09 Jun, 202609 Jun, 2026 NA
Tender For corrigendum : tender for supply of bulb 24v 40w b15 , bulb 40w , glass globe joint , o ring joint , bulb 115 60w b22 , bulb 24 v 40 w b15 , bulb 24 v 40 w b15 , bulb quartz iode 120v 250w , optical class , optical glass joint , pressure switch sensing element for fplm34dtxnsn , pressure switch sensing element for fplm34dkxsn , pressure switch sensing element for fpm34dqxnsn , temperature switch sensing elements for fcm34dgnsn , temperature sensor type pt 100b with ss316ti heath , configurable electronic module with pcb for emi protections , programmable temperature detector with 110mm probe length , temperature sensor assembly without electotronic module lm 176 , temperature sensor assembly without electotronic module lm 196 , flowrate signal processing unit amesys internation , typr 14p limit switch with a 20 m cable , 24 v aquacel type l37 reserve battery , pressure transmitter 0 15 bar absolute g 1 4 female , proximity detector neb 12 18mg50 e2 , remote thermometer 100mm type form 0 to 100 deg g full , thermometer 0100mm type a 0 to 100 degree c fcapillary k 2 m , manual call point , smoke detector , input module , limit switch contact , 1 0 m maximum height fresh water tank 1 level gauge , absolute pressure switch , conduct electrode h20 detect device al threaded coupling , differential pressure switch sensing element , electronic for fmb52 , electronic insert fel54 relays dpdt , level transmitter fmb52 , level transmitter fmb52 , position detector end valve fresh air pipe cm e 14 g21 3 , posn detector end vv air pipe cm e 14 g21 3 , pressure switch sensing element , pressure switch sensing element , pressure switch sensing element , pressure switch sensing element , pressure swith sensing element , pressure 60l alimentary quality balloon horiz or vert , dc dc converter , relay 2rt10a 28vcc , relay 4rt10a 28vcc , relay tpr2 28vcc , relay 6rt10a 28vcc , relay 6rt10a 28vcc , fuse series psc type 6 6 urd 30 tt f 0200 , cartridge fuse ha22 type 6 3 32 6 3 a , cartridge fuse ha22 type 6 3 32 1 6 a , monostable relay 10a 28vdc type 4 i 10 b1 p 28 , berard acturator oa8 115b 60 hz 3ph marline ral7038 , 115v 24 vdc converter , relay2rt 10a 28vdc suppressed device saphir code rel005appar , relay4 rt 2a 28vdc dc p

Central Government/Public Sector

CTN :45177487 Due date: 28 May, 202628 May, 2026 NA
Tender For corrigendum : supply of site mx emlsn explsv, emlsn, as per reqt , emulsion booster, emulsion, as per reqt , detonating fuse 10gm s/meter, class -6, , cord relays 25 milli second , cord relays 50 milli seconds

CTN :45115903 Due date: 29 May, 202629 May, 2026 NA
Tender For corrigendum : supply of static protective relays (q3)

CTN :45115920 Due date: 29 May, 202629 May, 2026 NA
Tender For corrigendum : supply of static protective relays (q3)

Central Government/Public Sector

CTN :41505654 Due date: 04 Jun, 202604 Jun, 2026 NA
Tender For corrigendum : supply, erection, testing and commissioning of numerical relays at ntpc singrauli

corporations/Associations/Others

CTN :45189416 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For corrigendum : supply of various types of numerical protection relays

CTN :45271786 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For rate contract for supply of material required for repair/maintenance /restoration of 33kv lines and 33/11kv receiving stations in respect of std-iv kalakote, for the year 2026-27 or till next contract. - 33 kv & 11 kv cable kits indoor/outdoor (make hot set or any other reputed make conforming to relevant is specifications) a) cable kits 33 kv single core heat shrinkable indoor 630 mm2, b) cable kits 33 kv single core heat shrinkable indoor 300 mm2, c) cable kits 33 kv single core heat shrinkable outdoor 630 mm2, d) cable kits 33 kv single core heat shrinkable outdoor 300 mm2, e) cable kits 11 kv single core heat shrinkable indoor 630 mm2, f) cable kits 11 kv single core heat shrinkable outdoor 630 mm2, g) cable kits 11 kv 3 core heat shrinkable indoor 400 mm2, h) cable kits 11 kv 3 core heat shrinkable indoor 300 mm2, i) cable kits 11 kv 3 core heat shrinkable indoor 240 mm2, j) cable kits 11 kv 3 core heat shrinkable indoor 185 mm2, k) cable kits 11 kv 3 core heat shrinkable indoor 120 mm2, l) cable kits 11 kv 3 core heat shrinkable outdoor 400 mm2, m) cable kits 11 kv 3 core heat shrinkable outdoor 300 mm2, n) cable kits 11 kv 3 core heat shrinkable outdoor 240 mm2, o) cable kits 11 kv 3 core heat shrinkable outdoor 185 mm2, p) cable kits 11 kv 3 core heat shrinkable outdoor 120 mm2, q) cable kits 11 kv 3 core (straight through joint), heat shrinkable 120 mm2, r) cable kits 11 kv 3 core (straight through joint), heat shrinkable 185 mm2, s) cable kits 11 kv 3 core (straight through joint), heat shrinkable 240 mm2, t) cable kits 11 kv 3 core (straight through joint), heat shrinkable 300 mm2, u) cable kits 11 kv 3 core (straight through joint), heat shrinkable 400 mm2, v) cable kits 11 kv single core (straight through joint), heat shrinkable 630 mm2, w) cable kits 33 kv single core (straight through joint), heat shrinkable 630 mm2, 11 kv cts of different ratios, make mei/ bicco lawrie / crompton greaves / bhel/ er/ ssg/ alstorm for 11 kv ocb/ vcb panelsi) 800/400/5-5, ii) 750/375/5-5, iii) 600/300/5-5, iv) 400/200/5-5, v) 300/150/5-5, vi) 150/75/5-5, spares for power transformersa) breather for 6.3 mva 33/11 kv transformer (2 kg), b) breather for 1.6 mva 33/11 kv transformer (kg), c) breather for 3.15 mva 33/11 kv transformer (kg), d) breather for 10 mva 33/11 kv transformer (3 kg), e) breather for 5 mva 33/11 kv transformer (2 kg), f) 20 mm lt bush rod for 33/11 kv transformer, g) 12 mm lt bush rod for 33/11 kv transformer, h) 20 mm copper bush rod assembly for 33/11 kv, 10 mva power transformer with oil seal, i) 12 mm copper bush rod assembly for 33/11 kv, 6.3 mva power transformer with oil seal, j) silica gel, k) oil seal for 33/11 kv power transformer, l) adaptor for bush rod extension for 33/11 kv power transformers, relays a) numerical relay (24-50 v) 3 o/c and 1 e/f relay of different make .(scada compatible), b) numerical relay (24-50 v) 3 o/c and 1 e/f relay of different make.(non-scada compatible), c) master trip relay 24-50 v ,of different make, 33 kv & 11 kv insulators make iec, bhel, rastriya, top line, tcpl or any other reputed make conforming to relevant is specification a) 33 kv pin insulator with pins (porcelain type), b) 33kv pin insulators for panther conductor with pins (polymer type), c) 33kv pin insulators for wolf conductor with pins (polymer type), d) 33kv pin insulators for dog conductor with pins (polymer type), e) 33 kv g.i. pins, f) 11 kv pin insulator (polymer type) with pins, g) 11 kv pin insulator (porcelain type) with pins, h) 11 kv g.i. pins, i) 11 kv disc insulator (b & s type) 70 kn (porcelain type), i) 11 kv disc insulator (b & s type) 120 kn (porcelain type), j) 33kv disc insulators (polymer type), k) 33 kv post insulator, l) 22 kv post insulator, m) 11 kv post insulator, n) drive insulator of sorts, o) shackle insulator, p) 11 kv guy insulator, q) 33 kv guy insulator, 33 kv tension fittings for acsr dog conductor, b&s 3 u-bolts type, 33 kv tension fittings for acsr wolf

Central Government/Public Sector

CTN :45275204 Due date: 29 May, 202629 May, 2026 NA
Tender For corrigendum : procurement of abb relays for ntpc vindhyachal

State Government

CTN :45275642 Due date: 02 Jun, 202602 Jun, 2026 3.07 Lacs
Tender For repairing and overhauling of one no twin lobe air blower assembly and renovation of 2 nos outgoing motor (blower ) feeder of lt pdb with supply, fitting and fixing spares at sludge pump house under swtp, kmda. - supply,installation,testing and commisioning of following items for hoisting system/ blower and gear box as mentioned below as per direction including cost of materials, machinaries , manpower, cutting,machining,aligning,anchoring,welding,finishing,consumables, carriage and all overheads with all leads and lifts complete as per specification (without painting), i) base frame (ms), ii) shaft/pin with key ways made of ss-304, iii) gear& pinion (forged steel), supply and fixing the 3way c.i v grooved pulley with complete mechanism key way suitable to en-24, 60 mm dia/ as per sample of shaft end., a) motor driving, b) blower driving, supply of gear oil as per direction of engineer in charge., supply of grease, supply and delivery of the following bearing (make: skf):, i) 22312e/c3/ as per sample. (for blower), supply and fixing of tough v belts (make: fenner/power boom / v guard/benq/ecodrive) of the following size c 98/ as per sample., supply fitting fixing of ss (aisi304) bolts,nut & washer i) dia 10 mm to 20 mm a) length upto 75 mm, refixing of impeller of blower after dynamic balancing in workshop as per is rule after dismantling the same., dismantling the 25/30 h.p (18.5 kw)//30 h.p squirrel cage motor from its foundation by opening mounting bolts and disconnection of cables from terminal box and open the v belts for repairing purpose (in condition), preliminary checking of the whole motor (lt sq. cage im) and testing of i.r. value, load currents, leakage factor of stator & rotor, terminal lead joints of stator connection ends, insulation of glass fibre terminal bar, double cage rotor end rings and all of motor bars and bar joints, housing of d.e. & nde shield bearing housing etc. before work to detect fault., complete servicing and heat varnishing of 415volt, 3 phase l.t. sq. cage induction motor after cleaning the stator and heating it up periodically and varnishing by dr. beck s graded insulating varnish to obtain stable ir value, cleaning up the rotor, including heating for demoisturisation, lacker coating on the surface of rotor stampings, cleaning and ro priming on the end shield covers, bearing housing and complete the necessary repairing works as per direction of e.i.c.upto 75kw lt sq. cage im ], re fixing the 25/30h.p star/delta squirrel cage motor over its foundation by mean of mounting bolts & nuts, washer complete connection of existing led of cable at the terminal box and wear the v belts with proper alignment in respect to i.d. fan (12000 cu m/hr capacity)/ blower by adjusting the side rail for smooth running., finishing the end of terminal leads by s & f dowells copper sockets properly supplying tapes, petrollium jelly etc. 6 nos.upto 75kw lt sq. cage im., cost of mechanical work viz. shaft truness, checking key way looping of holes grinding and polishing etc. upto 75kw lt sq. cage im., inspection checking/testing and servicing of the existing starter panel, all terminal connection, contactors, relays etc as per desired technical specification including man and minor materials for proper functioning as per direction of eic., supply and fixing of 240/230 volt, 50 hz, t.p., power contactor (make: l & /abb/schneider/ simence/ ge) having contact block of the following range.32-55amp, supply & fixing of 230/240v, led indicating lamp make :ae/kappa/imp) blue/ white color., supply & fixing of 230/240v, led indicating lamp make :ae/kappa/imp) other than blue/ white color., supply and delivery of thermal overload relays (make: l & t/abb/schneider/simence/ ge/minilec) of the following range:a) 0.2-0.33/ 0.3-0,5/ 0.45-0.75, mn2, supply of ammeter selector switch current in each phase with off, 4 pos. 90 angle ofthrow (off-r-y-b) , supply and fixing of analog ammeter ranging
 Loading, Please wait...

Connect us via What's Up