Tender For supply, fitment, installation, commissioning and testing of electrical variable voltage variable frequency ac drive rating-15kw/11kw, 3-phase 380-480 vac 50/60 hz, dc power supply: 510-680 vdc (cimr- ad4a0031fma).nominal input current (nd):24 amp. nominal input current (hd): 31 amp. output power rating (nd):15kw.output power rating (hd):11kw.frequency control range: 0-400hz.motor power-15kw/11kw.emc filter class c2 integrated. braking of standstill by dc injection. salient features: operation mode selection ,dc injection braking and short circuit braking ,speed search ,delay timer, pid control ,dwellfunction ,energy saving, acceleration and deceleration times ,slip compensation, torque compensation ,carrier frequency, frequency upper/lower limit torque control ,jump frequency. main control functions: torque control , drop control speed/torque control switch, feed forward control, zero servo control, momentary power,loss ride- thru and speed search, over torque detection, torque limit. speed control range : v/f control 1:40, open loop vector control 1:200, open loop vector control for pm 1:20, closed loop vector control for pm 1:1500, v/f control with pg 1:40 ,closed loop vector control 1:1500, advanced open loop vector control for pm 1:100. output overload tolerance: nd rating: 120% of rated output current for 60s, hd rating: 150% of rated output current for 60 s (derating may be required for repetitive loads).protection design: ip00 open-chassis, ul type 1 enclosure. ambient temperature (open-chassis): 10 to +50 degree celsius. standard compliance: ul508c iec/en61800 iec/en61800-5-1 ,two safe disable inputs and 1edm output according to iso/en13849-1 cat.3 pld iec/en61508 sil2. make: yaskawa /schnieder /abb/siemens/mitshubishi/angel or similar. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For corrigendum : replacement of defective quad cable patch along with emergency control circuit,tss/sp/ssp communication and cable joints in daund - wadi section of solapurdivision in central railway.
Tender For supply of circuit breaker,local control-30 amp to dlw drg.no.40037997 alt.aa,and to dlw part no.18310242 for wdp4/wdg4 locos [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of pcb circuit kit (electronic control unit cum buzzer suitable) for system and service cls panel 30a and 60a. (spare part suitable for system and service make cls panel) make - system and service [ warranty period: 12 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of sitc of wall mounted type microprocessor based afd control panel , supplying, installation, testing and commissioning of 20w, 4 feet led batten tube , sf led type solar street light fitting , replacing the faulty capacitor , supplying and fixing of wall fan , supplying and fixing 32 a dp switch fuse unit , sf 16 32a rewirable type fuse unit , s f 16 32a neutral link , wiring for light point ,fan point, exhaust fan point, call bell point group a , wiring for circuit, submain wiring 2 x 1.5 sq.mm 1 x 1.5 sq.mm earth wire , wiring for circuit, submain wiring 2 x 2.5 sq.mm 1 x 2.5 sq.mm earth wire , supplying and fixing following way , single pole and neutral , sheet steel, mcb distribution board 8 way, double door , supply and fixing following 5a to 32a rating , 240v, 415v, 10ka, c curve miniature circuit breaker single pole , supplying and fixing single pole blanking plate , supplying and fixing following rating, double pole, 240 volts, isolator 40 amps , supplying and fixing following rating , double pole single phase and neutral ,240 v ,residual current circuit breaker rccb , supplying and fixing call bell buzzer , supplying and fixing pvc batten angle holder , supply and fixing following modular switch socket 5 6 a switch , supply and fixing following modular switch socket 3 pin 5 6 a socket outlet , supply and fixing following modular switch socket 15 16 amp switch , supply and fixing following modular switch socket 6 pin 15 16 amp socket outlet , supplying and fixing following size modules, gi box 4 module 125mmx75mm , supplying and fixing stepped type electronic fan regulator , providing and fixing 4.00 mm dia copper wire on surface * /bid number : gem/2026/b/7665815 + /dated: 15-06-2026 ' ' / bid document 1 / 25
Tender For e-tender for procurement of some consumable items for two years from the date of award of contract (aoc)- disposable surgeons full wrap around gown specification: the products should be eo sterilized & ready to use, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 18g - length-15cm/10cm/8cm/ 6cm/4cm) with seldinger technique, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 22g - length-15cm/10cm/8cm/6cm/4cm) with seldinger technique, blood pressure equipment, sphygmomanometer, digital with pulse recording and 100 reading memory, blood transfusion set, sterile, disposable • medical grade non toxic and dehp free tubing with 200 micron filter • clear, transparent, flexible molded drip chambers with fix fluid filters and bacteria retention air vent transparent spike for easy piercing • efficient roller control for better flow control • molded “bulb type” injection site for extra medication • approximately 20 drops, l ml dw • sterilization by eto or more advance process. leur lock., bipap mask with bronchoscopy port along with accessories detachable & autoclavable vented / non vented swivel connector., blood cardioplegia device - adult - heat exchanger pleatal type. priming volume of heat exchanger : <30 ml . integrated heat exchanger with bubble trap. assemble with class vi implant tested tubing. high cooling eficiency. eassy set up and priming. outlet comnnection 1/4" built in bridge for choice of 100 % blood and 100 % cardiopledgia solution delivery., blower mister kit : comfortable hand grip with a 6.5" (16.5 cm) malleable stainless steel shaft for ease of positioning near the surgical site.the soft; silicon tip contains a plastic tube which carries saline to the tip ., burret set (100ml), c-arm cover 2 part materials-plastic, sterile pack, ready to use., catheter mount, collapseble catheter mount with bronchoscopy and suction port, cervical spinal locking plate assorted size with required screw, material – titanium, close suction with non returnable valve and terbojet clining system. sizes 10,12,14 fr., connector - straight assorted sizes - pvc material, sterile pack, coronary shunts assorted size : bevelled ultra-soft tip , obstruction -free flow path , large atraumatic sealing surface & flexible shaft., cvc3 fr. with anti kinking nitinol guide wire (paediatric)- 6cm/l0cm/15 cm with long shelf life >5 years. thermosensitive polyurethane double lumen paediatric cvc with accessories., cvp transducer : integrated unit for clinical accuracy. dual mode of flushing controlled squeeze and snap-tab. completely transparent for easy priming and debubbling with flushing of 3 cc / hr or without flush. easy zeroing. standard closed loop sampling kit / double. [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], cvp transducer compatible with arterial pulse contour monitor (disposable single use) [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], disposable sterile full gown with eye protection sterile disposable prepackaged, disposable ventilator circuit with single water trap. should be tidel volume range from 200 ml to 1500 ml. should be minimal deade space 55 ml. medical grade pe. connector 15/22 mm m/f for y piece, connector 15/22 mm m/f for ett & mask. standard length . 6ft. or expandable length., dome kit with flushing system. • should be single line monitoring dome. • should be measure invasive pressure., digital foetal doppler, eye drape • sheet size: 80 x 75 cm - 90 x 75 cm • adhesive area: 9 x 7 cm with 6 eye lid holders • drainage pouch of transparent pe film • eto (eo) sterile, face mask , disposable ,should be manufactured from non woven poly prop fabric ,should be 3 ply construction,should have high bacterial filtration efficiency ,should be cor ners, length of string should be 40 cmheat sealed to keep 3 layers together ,standard size 17.5 x 9 cm, colour green / blue ,th
Tender For e-tender for procurement of some consumable items for two years from the date of award of contract (aoc)- disposable surgeons full wrap around gown specification: the products should be eo sterilized & ready to use, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 18g - length-15cm/10cm/8cm/ 6cm/4cm) with seldinger technique, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 22g - length-15cm/10cm/8cm/6cm/4cm) with seldinger technique, blood pressure equipment, sphygmomanometer, digital with pulse recording and 100 reading memory, blood transfusion set, sterile, disposable • medical grade non toxic and dehp free tubing with 200 micron filter • clear, transparent, flexible molded drip chambers with fix fluid filters and bacteria retention air vent transparent spike for easy piercing • efficient roller control for better flow control • molded “bulb type” injection site for extra medication • approximately 20 drops, l ml dw • sterilization by eto or more advance process. leur lock., bipap mask with bronchoscopy port along with accessories detachable & autoclavable vented / non vented swivel connector., blood cardioplegia device - adult - heat exchanger pleatal type. priming volume of heat exchanger : <30 ml . integrated heat exchanger with bubble trap. assemble with class vi implant tested tubing. high cooling eficiency. eassy set up and priming. outlet comnnection 1/4" built in bridge for choice of 100 % blood and 100 % cardiopledgia solution delivery., blower mister kit : comfortable hand grip with a 6.5" (16.5 cm) malleable stainless steel shaft for ease of positioning near the surgical site.the soft; silicon tip contains a plastic tube which carries saline to the tip ., burret set (100ml), c-arm cover 2 part materials-plastic, sterile pack, ready to use., catheter mount, collapseble catheter mount with bronchoscopy and suction port, cervical spinal locking plate assorted size with required screw, material – titanium, close suction with non returnable valve and terbojet clining system. sizes 10,12,14 fr., connector - straight assorted sizes - pvc material, sterile pack, coronary shunts assorted size : bevelled ultra-soft tip , obstruction -free flow path , large atraumatic sealing surface & flexible shaft., cvc3 fr. with anti kinking nitinol guide wire (paediatric)- 6cm/l0cm/15 cm with long shelf life >5 years. thermosensitive polyurethane double lumen paediatric cvc with accessories., cvp transducer : integrated unit for clinical accuracy. dual mode of flushing controlled squeeze and snap-tab. completely transparent for easy priming and debubbling with flushing of 3 cc / hr or without flush. easy zeroing. standard closed loop sampling kit / double. [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], cvp transducer compatible with arterial pulse contour monitor (disposable single use) [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], disposable sterile full gown with eye protection sterile disposable prepackaged, disposable ventilator circuit with single water trap. should be tidel volume range from 200 ml to 1500 ml. should be minimal deade space 55 ml. medical grade pe. connector 15/22 mm m/f for y piece, connector 15/22 mm m/f for ett & mask. standard length . 6ft. or expandable length., dome kit with flushing system. • should be single line monitoring dome. • should be measure invasive pressure., digital foetal doppler, eye drape • sheet size: 80 x 75 cm - 90 x 75 cm • adhesive area: 9 x 7 cm with 6 eye lid holders • drainage pouch of transparent pe film • eto (eo) sterile, face mask , disposable ,should be manufactured from non woven poly prop fabric ,should be 3 ply construction,should have high bacterial filtration efficiency ,should be cor ners, length of string should be 40 cmheat sealed to keep 3 layers together ,standard size 17.5 x 9 cm, colour green / blue ,th
Tender For alteration in existing electronic interlocking (ei) system at noh, szn, mala, sgand pp stations in connection to modified calling on control circuit and modifiedpoint detection circuit and preparation of integrated cable route plan of various sand t cables laid in station and block section in izn division
Tender For purchase of tanche - lab equipments for eee and ece department - purchase - lab equipments for eee department electronics lab, single phase to single phase cyclo converter kit single-phase bridge cycloconverter power devices: scr/triac based input supply: 230 v ac, 50 hz step-down isolation transformer 230 v / 12 v output: 12 15 v ac, frequency: 0 25 hz (adjustable),firing angle control circuit and frequency control circuit to be provided built-in resistive load, terminals to be brought on ms panel with necessary symbols and circuits, pwm based step down dc chopper using mosfet/igbt kitpwm based step-down dc chopper (buck converter) power device : power mosfet / igbt based switching circuit input supply : 24 v dc to 110 v dc or derived from 230 v ac mains through rectifier unit output voltage :(0 to vin) variable dc output current : up to 5 a dc maximum with suitable load resistor (r load) pwm duty cycle control provided pwm generation and control circuit inbuilt gate driver circuit provided, single phase single pulse / sinusoidal pwm inverter using mosfet/igbt kittype : single phase pwm inverter trainer power device : mosfet / igbt based inverter circuit input supply : 12 24 v dc output voltage : 30 v rms ac output phase : single phase output frequency : 0 50 hz variable output power : 100 w single pulse pwm operation sinusoidal pwm (spwm) operation variable frequency control pwm generation and firing control circuit inbuilt gate driver circuit provided test points provided for waveform observation and analysis built-in resistive load provision, on / off control of lamp using solid state relay kittype : solid state relay (ssr) trainer kit control/input voltage : 12 v / 24 v dc or up to 30 v dc output load voltage : 230 v ac, single phase load control : on/off control of ac lamp load solid state relay based switching circuit opto-isolated input control built-in ac lamp load manual on/off switching arrangement led indication for input and output status, speed control of ac motor using vfd drive module with ac motortype : variable frequency drive (vfd) module input supply : 415 v ac, three phase, 50 hz output : three phase variable voltage and variable frequency ac output 1 hpthree phase squirrel cage induction motor415 v ac 50 hz &1440 rpm control technique : pwm / spwm based control frequency range : 0 50 hz variable digital display for frequency and operating parameters start / stop and forward / reverse control, acceleration and deceleration control facility powder coated ms control panel tabletop / floor mounted laboratory type setup clearly labelled circuit diagram and control switches proper insulated terminals and earthing arrangement, purchase - lab equipments for eee department electrical machines lab, three phase transformertype: three phase transformer, rating: 3 kva input voltage: 415 v ac, 3-phase, output voltage: 230 v ac, 3-phase frequency: 50 hz winding material: copper wound insulation class: class b or higher duty: continuous duty suitable for laboratory usebench/floor, dc stepper motor drive kit with stepper motorinput supply : 230 v ac, 50 hz stepper motor : permanent magnet / hybrid type with suitable driver circuits. motor operating voltage : 12 24 v dc variable speed control forward and reverse direction control full step and half step operation manual / automatic pulse generation facility built-in regulated dc power supply led indication for phase sequence and status test points provided for waveform observation start / stop control switches to be provided overload and short circuit protection to be provided mounted on compact powder coated cabinet with printed circuit diagram proper insulated terminals and interconnecting leads to be provided patch chords for interconnection., dc servo motor drive kit with servo motorinput supply : 230 v ac, 50 hz servo motor type : dc servo motor with feedback arrangement motor operating voltage : 12 24 v dc controller type : microcontroller based servo drive contr
Tender For purchase of ece department lab electronics equipments - equipments for ece, dual output regulated dc variable power supplyinput voltage : 230v/50hz acoutput voltage :(0-30)v dcoutput current :(0-2)a dcprotection circuit : over voltage, over current, and short-circuit protectionhigh efficiency : greater than 85%low ripple and noise : less than 50 mvdigital display, function (signal) generatorspecs:frequency range : 0.1hz to 5mhzdisplay :4 to 6 digit led displayoutput waveforms : sine, triangle, square, pulse, rampamplitude :0-20 vpprise time :100 nsdistortion : 1% within specified frequency rangepower supply : 230v ac 10% , 50-60 hzoutput amplifier protection : short circuit and 15voverload protectiondc offset: 0 to 10 v adjustableattenuation: 0 to -60 db, decade resistance box range : 1 to 1m rotary switch selection with 6 dialssteps : 1 , 10 , 100 , 1k , 10 k , 1m accuracy : 1%, decade capacitance box range : 100 pf to 100 frotary switch selection with 6 dialsmaximum voltage : 350vaccuracy : 1%, decade inductance box range : 10 h to 10 hrotary switch selection with 6 dialslow-loss inductorsaccuracy : 1%, sim reader trainer kitpower supply :operates on 230v ac 10%, 50hz mains supplybuilt-in regulated smps power supplyoperating dc supply : 5v/12v with overload and short-circuit protectionsim card interface :supports gsm sim cards compatible with 2g / 3g / 4g / 5g networkssim card read/write interfacesupports sim card initialization, authentication and communication functionscompatible with standard 6-pin / 8-pin sim card socketscommunication interface :usb 2.0 interface for pc communicationrs-232 serial communication interfaceuart communication facility for embedded system interfacingsim operating parameters :selectable sim clock frequencies3.579 mhz7.159 mhz14.318 mhzsim supply voltage selection facilitysim reset and activation controlsupported protocols and standards :gsm etsi 07.07 and etsi 07.05 at command supportiso/iec 7816 smart card communication supportsim communication command monitoring facilityhardware features :on-board sim card socketled indication for :power statussim detectionreset activityuser manualutility software cd / downloadable software packagedata transmission/receptionbuilt-in keypad for standalone operation.lcd display module (128 64) for menu and status display.on-board microcontroller-based control section.software support:at command execution and monitoring software.sim manager utility software.data logging and communication terminal utility.pc-based gui software for sim data communication experiments.trainer features:fault simulation facility for troubleshooting experiments.simulation of faults such as:sim not detectedclock failurevcc failurereset failuremultiple on-board test points for signal observation.test points for:sim rstsim_clksim iovccuart tx/rxsuitable for cro/dso signal monitoring.glass epoxy pcb with educational block diagram layout.compact tabletop enclosed cabinet design.construction:front panel with printed block diagram.banana test points and patching facility.standard accessories:gsm sim trainer unit.usb communication cable.rs-232 communication cable.power cord., microwave test bench with reflex klystron oscillatormicrowave source :relex klystron tube with klystron mountoperating frequency in x-band (8.2ghz to 12.4ghz)electronic tuning through repeller voltage controlsuitable for cw microwave generationklystron powersupply:regulated klystron power supply unitbuilt-in modulation facilityoverload and short circuit protectionoperates on 230v ac 10%, 50hz mains supplywaveguide components:isolator variable attenuatorfrequency meterslotted line section with tunable probecrystal detector mountmatched loadmovable short / terminationwaveguide stands and accessoriesmeasurement unit:solid state vswr meter with high sensitivityswr measurement facilitysuitable for detector output monitoringtechnical specification :frequency range : 8.2 ghz to 12.4 ghzwaveguide types : wr-90detector type : crys