Tender For supply of chemical - microtiter plates , racked micro tips 10 , racked micro tips 200 , racked micro tips 1000 , microtips with filter 100 , carboy with stopcock , macro tips 5 , macro tips 10 , macro tip box 10 , macro tip box 5 , microcentrifuge tube point 5 , microcentrifuge tube 2 , 96 place reversible rack for microcentrifuge tubes , test tube basket with cover , test tube basket with cover 180030 , tong for beaker and flask , hiindicator ph paper la 312 , hiindicator ph paper la 318 , hiindicator ph paper la 321 , hiindicator ph paper la323 , spatula 10 inch , saptula 6 inch , spatula micro , pipette controller , pipette rack horizontal , pipette stand , micropestle , nitrile gloves medium , nitrile gloves large , hand protector grip , test tube stand 20 places , test tube slank rack stand 40 places , draining tray
Tender For corrigendum : supply of air compressor spares - neuron ii controller , oil filter eelment , air filter eelment , coup. elemet rotex , air lube plus , element separator , auto drain , single ph. preventer
Tender For empanelment of agencies for supply of laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoridemeter: ph/ise benchtop meter with electrode stable, universal power adapter, literature, pc cable, meter test certificate electrode: ionplus fluoride and nitrate combination ion selective electrode, 1m cable, waterproof bnc benchtop ion meter (ise) along with fluoride, nitrate #electrode range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 relative accuracy 0.002 calibration points up to 5 calibration editing yes #mv/ rmv orp range 2500.0 mv resolution 0.1 relative accuracy 0.2 mv or 0.05 % of reading whichever is greater eh orp mode yes ise range 0 to 19999 resolution up to 3 significant digits relative accuracy 0.2 mv or 0.05 % of reading whichever is greater units ppm, m, mg/l, %, ppb, none calibration points up to 5 calibration editing yes calibration features timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability #temperature range -5 to 105 c, 23 to 221 f resolution 0.1 relative accuracy 0.1 offset calibration 1-point datalogging memory 2000 with time and date stamp log function manual, ready (include auto-read ), timed log edit delete individual points, group of points or all inputs ph electrode bnc, reference pin atc probe 8-pin mini-din #output rs232, usb power ac adapter included universal, 100-240 vac battery power optional 4 aas battery life 800 hrs, fluoride electrode of ion metersame make that of the ion meter, manifold filtration assembly* wide range of pumps and filtration flasks * high quality components * easily exchangeable elements *maintenance-free * low noise * added filters for enhanced pump longevity * filtration base with silicon stopper, cap & aluminium clamp connecting silicon tube technical specification for filtration flask set # high-pressure resistant tube # fiberglass filter membranes (47mm / 0.1 m) # ptfe disc filter #normal liquid filtration * specification for filtration glass set #suction bottle capacity(ml) 1000 ml # filter diameter(mm) 47/50 mm # * specification for filter flask * material: statinless steel 304, capacity: 300 ml (100 ml each) [ unit should consist of 3 flask so that 3 sample can be filtered simultanelously without any issue] # effective filtration area(cm2) = 9.6 cm2, outlet connector(mm) = 8 mm * specification for vaccum flask: #flow rate of the pump(l/min) = 17 l/minultimate vacuum(mbar) = 150 mbar # oil free, maintainance free, built in thermal protection to shut off when over heated., auto cut heater for distill water plant so that when water level decreases the heater is switch off automatically, voltage stabilizer capacity- 3 kva servo stabilizer 5 star rating, heating mantle (single station) should have digital energy regulator with multiple step power regulation automatic spill detection and saftey shutdown in built precision temperature control technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 420 degree celcius. accuracy: plus minus 1.0 degree celcius, power consumption : 150 w, heating mantle (combined unit) material of construction heating block: made with grade epoxy painted chemical resistant coating, aluminum block with 6 thermo wells for processing 6 different samples at a time. #racks: ss 316 # glassware: teflon coated # temperature range ambient + 10 deg c to 450 deg c # stability of temperature better than 0.5 deg c # controller consist of digital read out of temperature and time with 4 programmable ramps for each method. # number of programmable methods 20 numbers. # heating powers 1000w # heating position minimum 6 position # digestion time range -1 to 999 minutes # the system should have facility of acoustic signal at the end of completion of cycle to notify the operator. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint. # th
Tender For corrigendum : providing and installation of electrical accessories and allieds works at shaspur pwss, block-rampurhat-ii under bolpur mechanical division - supply, delivery at site and storage of wall mounted made of sheet steel fabricated 2 mm for load bearing & 1.6mm for non load bearing, indoor type, dust & vermin proof, lp-54 degree of protection, powder coated painted with rubber gaskets cover, front lockable hinged door with all switchgear and other items duly wired up and tested as per specification: incomer: (a) 100 amps, tpn mccb with adjustable ol, 36 ka, e/f, auto phase corrector & necessary accessories with suitable spd (i.e., ammeter, voltmeter, cts & switches), outgoing:- (b) 7.5 hp to 12.5 hp, tp star-delta starter with other accessories - 1 nos., (suitable size capacitor bank to improve pf from o.85 to 0.98) (c) yard lighting feeder with necessary accessories & time switch(digital) - 1 no. (d) 3phase actuator valve starter with other accessories -1 nos., (e) 2 hp ,3 ph,415v,clorinator feeder with necessary accessories & level controller-1 no., (f) 32a mccb fdr for iep/misc purpose-1no., (g) 32a mccb for in house light-1no.,(e) plc feeder with necessary accessories-1no.( all spare & components as per vendor list of phed), supply and delivery at site of 15 kva, 3phase, oil cooled type servo motor operated copper wound line voltage corrector conforming to is-9815 (pt.-1)- 1994 suitable for un-balanced input voltage with following specification including first filling oil as per is-335 where applicable.a) input voltage:- 3 phase, main supply may or may not be balanced with respect to phase to phase- 200v-500v phase to neutral-115v-290v.b) output voltage:-3 phase balanced output voltage. phase to phase- 400vor 415v 1%, phase to neutral- 230v-240v 1% (provision should be made to adjust the variation of output voltage per phase by a variable pot oil within 5% of output).c) line regulation:- out put voltage should remain well with 1% of set voltage (from minimum to maximum i.e. either 400v. or 415v. supply variation).d) load regulation : output voltage should remain neutral well within 1% of set voltage be ( from no load to full load ) i.e. either 400v. or 415v.e) correction speed:- better than 35 volt / second.f) efficiency:- better than 95% on full load.g) cut off limit (minimum &maximum ) by limit switch with audio & visual.h) metering indication:- by selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available.i) lamp indication :- for input & output should be provided. ( 3 lamps per side ).j) mcb protection: for input side.k) load protection : hrc fuse on each output phase should be availablel) output over shoot:- beyond 210v to . 255v /phase in case of manual mode & voltage protection :auto mode operation.m) visual indication for under voltage & over voltage of output.n) manual mode:- up & down correction with o / p voltage over shoot protection. beyond 210 v-255 v. per phase.o) nature of cooling:- oil cooled system.p) electric current over load protection .q) circuit for delay output .r) input high voltage cut-off above 500 v.s) mode of operation:- auto/manual with a provision to restore the normal working of the unit standby operation should be available in case of any electronic failure in auto mode., installation of mcc panel along with main switch, changeover, busbar chamber, cut out etc. all electrical equipment within the pump house, drawing of cable properly on suitable size gi cable tray on wall / as per direction of eic as per layout & ie rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fixing of materials for taking power within the pump house from wbsedcl end as per direction of eic. [for ph no - i, ii & iii], installation of above