Get complete information related to latest Titrator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Titrator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Titrator Tenders.
Tender For providing of custom bid for services - rate contract for maintenance, servicing & calibration of microprocessor based potentiometric titrator for tan analysis instrument (model: titroline 7000, make: si analytics) of chemical lab, ctps, dvc on oem/oes basis
Tender For bid to ras supply of auto titrator - auto titrator , amc charges for 1st yr , amc charges for 2nd yr , amc charges for 3rd yr , amc charges for 4th yr , amc charges for 5th yr
Tender For purchase of fire safety and fighting laboratory equipment for fts department - purchase of fire safety and fighting laboratory equipment for fts department, cleveland open cup (coc) apparatus standard compliance: astm d92 / is 1448 (part 69) test method: open cup flash and fire point determination test cup: brass, precision machined with heat resistant handle heater: electric heater (1000 w 10% nickel chromium) with variable control heating rate: 5 c per minute (as per standard) temperature range: (-6 to 400) c thermometer: astm 11c or equivalent flame applicator: gas test flame with fine control valve body: stainless steel housing display: analog / digital temperature indicator power supply: 230v ac, 50 hzsafety: overheat protection heat insulation, pensky-martens closed cup apparatus standard compliance: astm d93 / is 1448 (part 21) type: pensky-martens closed cup (motorized, digital type preferred) test cup: brass cup diameter: 50.7 50.8 mm capacity: minimum 70 ml stirring system: heater: electric heater 650 w 10% heating rate: 1 12 c/min adjustableignition:pilot flame with automatic shutter mechanismtemperature measurement:thermometer or digital sensor (ip-28c or astm)digital temperature displaypower supply:230v ac, 50 hzsafety: over-temperature cut-off flame safety control
Tender For supply of analysed oil samples and disposal record , boiler water analysis record , calibration record, carbon analyzer , calibration record, flame aas , calibration record, analytical balance , calibration record, mass spectrometer , calibration record, weight box, e1 , calibration record, gc, mp , calibration record, ion chromatograph , calibration record, kf titrator , calibration record, ftir , calibration record, conductivity meter , cooling water analysis record, landscape , calibration record, density meter, dma 58 , density meter calibration record , dissolved oxygen record , dm plant cpp analysis record , dm plant analysis record , calibration record, flame photo meter , calibration record, h2s gas bombs, ss sample containers , lab effluents discharge , monthly report for trade effluents , na2so4, recovery analysis record , ng heavy water analysis record , non returnable material dispatch record , oxygen 18 sample analysis record , observation book for kmno4 demand , pc and al analyzed samples disposal record , calibration record, ph meter , process liquids analysis record , raw material analysis record, h2so4 , raw material analysis record, naoh , raw material analysis record, na2s and nahs , raw material analysis record, hci , raw material analysis record, alum , raw material analysis record, libr , raw water treatment plant analysis record , rcu gas analysis record , seal and lube oils analysis record , system and purge gas analysis record , calibration record, turbidity meter , uv visible observation book , waste stripper average record , xu samples analysis record , bottom ash analysis record , boiler feed, dissolved oxygen, iron and copper record , flue gas analysis record , scc ltd. coal analysis record , spm analysis record , single ruled book
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r