Get complete information related to latest Tone Tracer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tone Tracer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tone Tracer Tenders.
Tender For dismantling, pre testing, repairing, assembly, installation, testing and commissioning at site of 750 kva, 0.4 11kv generator transformer of machine no. 05 of bhola power house.
Tender For design, manufacturing, supply, delivery, installation, testing and commissioning of hydraulic power pack including heat exchanger and electrical control panel for operation of caisson, as replacement of existing machine by dismantling of old one, including 5 (five) years comprehensive maintenance contract (cmc) after expiry of 2 (two) years defect liability period (dlp) at lock entrance of haldia dock complex (hdc), syama prasad mookerjee port, kolkata (smpk).
Tender For supply delivery and replacement of spares for sub-station at mandalkuli water supply scheme , raipur block under bankura mechanical division, phe dte. - "control transformer supply80 va, 240 v / 110 v", "aux contractor supply (4 no 4 nc)make: siemens / abb, coil voltage: 110 v ac", "pcb relay card supply for avr as per existing circuit ", voltage controller potentiometer (1k) supply, "1100 va ups supply output power wattage 660w or equivalent , input-50 hz , wide input voltage range 145-290 v, 2x 7.2 ah (or equivalent) battery , provides 30-90 min power back upmake: apc, input: 230 v ac", "240 sq. mm. x 3 core, 11 kv grade, indoor type, heatshrinkable end termination kit supply ", "240 sq. mm., 11 kv grade, indoor type, heatshrinkable kit jointing charges", "avr throughout inspection and control operation checking and rectification by opening the cover , checking the throughout circuits with aux. contractor replacement charges, pcb relay card with voltage controller potentiometer replacement charges, control transformer replacement charges, old ups replacement and new ups installation charges fixing of heat srinkable kit & other as per direction . ", supply and delivery of following spares for battery charger panel:, supply of 65 ah smf vrla battery with 6 nos cell, polyproplene container make: exide, consisting of 9 nos. 12 v batteries (model-ep 65-12 or equivalent), "charges for old defective battery rack by disconnection all the electrical circuit and fitting fixing of the new battery rack fittings,connection of all batteries checking otesting for a certain period. ", "supply of 2.5 sq. mm x 4 core cu armored cable forbattery charger panel to 3 panel vcb , as per is-7098 (part-i )", gland supply for 2.5 sq mm x 4 core cu armored cable, laying charges of 2.5 sq. mm x 4 core cu armored cable, "charges for glanding & socketing for 2.5 sq mm x 4core cable for battery charger panel: as per direcrion of eic", "supply and delivery of following spares for 400 kva, 11 kv/433 v, transformer-1 & 2:", oti (4 inch. dia) supply make: ptci, "wti (4 inch. dia) supply make: ptci", oti replacement charges, wti replacement charges, "supply of 2.5 sq. mm x 10 core cu armored cable for 3panel vcb to transformer-1 & 2 as per is-7098 (part-i ) ", gland supply for 2.5 sq mm x 10 core cu armored cable, laying charges of 2.5 sq. mm x 10 core cu armored cable , supply of 2.5 sq mm cu pin lugs , supply of 2.5 sq mm cu fork lugs, "charges for glanding & socketing for 2.5 sq mm x 10core cable of 400 kva, 11 kv/433 v, transformer-1 & 2: as per direction of eic", supply and delivery of following spares for single panel vcb:, 240 sq. mm. x 3 core, 11 kv grade, indoor type, heat shrinkable end termination kit supply, 240 sq. mm., 11 kv grade, indoor type, heat shrinkable kit jointing charges, 200-watt space heater supply make: reco, 230 v , "thermostat supplymake: elcon gold, model: mm-106,range: 30? c - 110? c, 15 amp., 230 / 250 v ac", "3 nos. space heater along with 1 no. thermostatconnection wiring charges as per direction of eic", supply and delivery of following spares for 3- panel vcb: , "240 sq. mm. x 3 core, 11 kv grade, indoor type, heatshrinkable end termination kit supply", "240 sq. mm., 11 kv grade, indoor type, heat shrinkablekit jointing charges", 200-watt space heater supply make: reco, 230 v , "thermostat supplymake: elcon gold, model: mm-106,range: 30? c - 110? c, 15 amp., 230 / 250 v ac", 2.5 sq. mm. s/c, 1.1 kv grade control cable supply for space heater and thermostat wiring , "2 nos. space heater along with 1 nos. thermostatconnection wiring charges for each panel as per direction of eic", "3 nos. space heater along with 1 no. thermostatconnection wiring charges as per direction of eic", attending the fault at mandalkuli, bankura district with carrying different testing, servicing kit/machine like insulating resistance checking machine (1 kv, 2.5 kv, 5 kv) 3 phase variac, current injection machine/ kit, voltage
Tender For purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat a
Tender For corrigendum : supply of stacked antennas with necessary fixing or mounting kits , rf cable with n type male connectors , vhf receiver active multicoupler 08 port , surge protector for rf cable , rf pigtail with n type male and female connector ends , rf pigtail with n type male connectors at both end , rf n type 8 port female to female patch panel , 50 ohm 5w dummy loads , 50 ohm 10 db attenuators , 50 ohm 20 db attenuators , portable vswr metre or rf power reflection metre with forward and reverse elements , rf adaptors kit , rf n type female to female convertor , rf n type male to female convertor , rf n type male to male convertor , rf cables crimping tool , vhf battery 12v 100ah , vhf battery charger , dc power cable , 3 core 2.5 sq mm power cable , 2 pole isolator , dc 24 v anti over discharge charging controller protection board , rj45 patch panel , esd workbench , esd mats , self supporting ladder , power drill machine with toolkit , adjustable dc regulated power supply 0-48v , multimeter average responding type , krone punching tool , rj45 and rj11 crimping tool , screwdriver set , lan tester , allen key set , installation,testing and commissioning works
Tender For corrigendum : dehydration and filtration of transformer oil of 132/33 kv, 20/25 mva,emco make old power transformer, at 132 kv gss rapp, rawatbhata(dist chittorgarh) along with man power and high vacuum filter machine and oil testing kit having 100 kv capacity
Tender For corrigendum : supply of lcd kvm switch with integrated mouse and keyboard , rackmount power strip iec c13 , laptop , desktop pc - cpu without monitor , monitors , monitor arm , antivirus license -for 15 pcs and 4 laptops , firewall , hub -rj45 , wi- fi router , displays - tv with stand , hdmi cables , wireless printer cum scanner , windows server operating system , ntp server with integrated gps clock , photocopy machine , wireless presentation system , ms office - for 15 pcs and 4 laptops , installation, testing and commissioning of acdm lab , onsite support engineer - total duration of three year , server (q2) , layer - 3 core switch (q2) , layer 2 access switch (v2) (q2) , networking / server rack (q2) , cat 6 patch cord (q2)
Tender For corrigendum : procurement of lab instruments for chemical lab of ogcd, dtps, htps, kasimpur - sension5 portable conductivity meter specification range:#conductivity s/cm 0 to 19.99; 200 to 1999#conductivity ms/cm 2 to 19.99; 20 to 199.9#tds: 0 to 50,000 mg/l as nacl salinity: 0 to 42 g/l (ppt)#temperature: -10.0 to 105.0 c#resolution:#conductivity 0.01; 1.0#conductivity ms/cm 0.01; 0.1#tds: 0 .00-199.9 mg/l 0.1mg/l 2 00-1999 mg/l 1 mg/l 2 .00 -19.99 g/l 0.01 g/l 2 0-50 g/l 0.1g/l #salinity: 0.1 g/l (ppt)#temperature: 0.1 c#accuracy:#conductivity: 0.5% in the first 3 ranges, 1% at highest range #td of full scale #salinity: 0.1 ppt (-2 to 35 c) #temperature: 0.1 c# , make-hach, ph meter probe (ph meter sension ph3) cat no-lzw5010t.92.0002 make hachdetails in photograph enclosed in tender document, manual sieves shaker (with sieves set - mesh size-50,+100,+200) any standard make details in photograph enclosed in tender document, centrifugal machine for oil testing, any standard maketube capacity:no.12-24:size 15 mlshould have a digital timerbody should be made of strong fabricated & corrosion resistant steel.control panel- for start/stop switch, dynamic brakes, step less speed regulator with zero start switch & speed indicator with timer and protective fuses.door interlock.maintenance free brushless drive motor with exact speed preselection and display. speed range 100 to3000 rpm and above, accuracy 1 rpm. details in photograph enclosed in tender document, orset appratus (complete set), any standard make details in photograph enclosed in tender document, ph 2700 ph meter specification #ph range -2.000 to 20.000 ph #resolution 0.1 / 0.01 / 0.001 ph #accuracy 0.002 ph + 1 lsd #cal. points up to 6 preset or 5 custom #buffer sets usa, nist, din, user 1, user 2, custom #or range 2000.0 mv #rel. mv range 2000.0 mv on 0.1 mv# accuracy 0.2 mv #temperature,range (meter) 0.0 to 100.0 c / 32.0 to 212.0 f #resolution 0.1 c / 0.1 f #accuracy 0.3 c / 0.5 f #compensation atc / mtc #power requirements 9 v dc adapter, 1.3 a (100/240 vac, smps)# make- eutech
Tender For supply, installation, testing and commissioning of movable continuous renal replacement therapy (crrt) machine for the department(s) of general medicine and critical care medicine skims. - equipment, rate of main equipment, inclusive of all levies, such as transportation charges, installation charges, power/ups except gst), cmc, cmc amountfor ist year except gst, cmc amiount for 2nd year except gst, cmc amount for 3rd year except gst, cmc amount for 4th year except gst, cmc amount for 5th year except gst, consumables, rrt kits (cassette + filter) per annum requirement, crrt fluid (5 liter/bag) per annum requirement