Get complete information related to latest Torniquet Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Torniquet Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Torniquet Tenders.
Tender For supply of tac med items b b - junctional torniquet , non rigid litter foldable stretcher , pelvic stabilization device , pocket bag valve mask collapsible ambu bag , hypothermia blanket with heat packs , first aid kit , bfna kit
Tender For supply of srphc82278027-crt- p pulse generator for delivery of cardiac resynchronization therapy. system should include a current generation crt pulse generator compatible with bipolar steroid-eluting atrial and ventricular leads and a biploar left ventricular lead (coronary sinus ). should provide independently programmable right and left ventricular pulse outputs and interventricular delay ( with the choices of right ventricular alone, leftventricular alone or biventricular pacing as well as the choice of which ventricle is to bepaced first with optimization of delay for pacing of other ventricle ). should have features like negative av hysteresis and triggered modes for continuous delivery of crt. should have advanced features for detection and management and prevention of atrialtachycardias and atrial fibrillation as well as detailed data storage of all arrhythmias and therapy as well as trends over time. should have features for management of atrial fibrillation including mode switch, ventricular rate management etc., pulse generator should be suitable for use with either an endocardial lv lead or an epimyocardial lead for lv stimulation. lv leads should have optimal features for introduction, positioning and fixation and documented low displacement rates. safety and efficacy of the system should be well documented. unit: number. ]
Tender For supply of 34020 - esmarch torniquet - size 6" 1. latex & latex free(polyisoprene), 2.can be sterilized (gamma or eto) 3.length minimum 10feet 4.sterile packed. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : e-tender for the supply of various implants and consumables for department of orthopaedic of r.g. kar mch - periprosthetic proximal femoral plate and binding cable set (made of titanium)(rates for each sub item must be given, cummulative lowest bidder will be treated as l1 bidder), periprosthetic proximal femoral plate with screw -full set (made of titanium), binding cable (made of titanium), pelvic reconstruction plates and quadrilateral butress plates set (made of lvm)(rates for each sub item must be given, cummulative lowest bidder will be treated as l1 bidder), pelvic reconstruction plates with screw full instrument set (made of lvm), pelvic quadrilateral butress plates with screw full instrument set(made of lvm), 4mm arthroscope 70degree with trocar and cannula, single cuff torniquet machine, osteochondral autograft transfer system (oats)-full set, total elbow arthroplasty-full instrument set, cone for tka, reciprocating saw handpiece (battery operated) with battery and charger
Tender For supply of srphc82278027-crt- p pulse generator for delivery of cardiac resynchronization therapy. system should include a current generation crt pulse generator compatible with bipolar steroid-eluting atrial and ventricular leads and a biploar left ventricular lead (coronary sinus ). should provide independently programmable right and left ventricular pulse outputs and interventricular delay ( with the choices of right ventricular alone, leftventricular alone or biventricular pacing as well as the choice of which ventricle is to bepaced first with optimization of delay for pacing of other ventricle ). should have features like negative av hysteresis and triggered modes for continuous delivery of crt. should have advanced features for detection and management and prevention of atrialtachycardias and atrial fibrillation as well as detailed data storage of all arrhythmias and therapy as well as trends over time. should have features for management of atrial fibrillation including mode switch, ventricular rate management etc., pulse generator should be suitable for use with either an endocardial lv lead or an epimyocardial lead for lv stimulation. lv leads should have optimal features for introduction, positioning and fixation and documented low displacement rates. safety and efficacy of the system should be well documented. unit: number. ]
Tender For bid to ras supply of combat gauge 10 x 10 cm quikclot , chitosan hemostatic dressing 8 x 8 cm , israeli bandage 4 inch , chest seal hyfin , needle for pneumothorax , cat torniquet gen 7 , cervical collar , waterjel burn dressing 10 x 10 , leg traction splint , survival blanket large , light weight portable emergency stretcher , gsw dressing mk 300 7.6 cm 300 cm