Get complete information related to latest Touch Screen Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Touch Screen Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Touch Screen Tenders.
Tender For bid to ras supply of 1527091540-8 port non poe 10/100/1000 mbps network switch make digisol/ d-link or equivalent , 1527283017- 24 port web managed poe+ layer2 switch for cctv camera; numb ers of 1g port= 24 nos. ; n , 1527283018- 8 port web managed poe+ layer2 switch for cctv camera; numbe r of 1g port= 8 nos. ; numb , 1527283021- 8 mp bullet ip camera having ir range: 30 mtrs; weather proo f standard: ip67; power sou , 1527283022- mp ptz ip camera having ir range: 175 mtrs, weather proof standard: ip67; optical zoom: , 527283023- 2 mp bulet camera having ir range: 80 mtrs; res. 1920x1080; weather proof standard: ip67; , 1527283024- 16 port giga poe switch having 2 giga up link port & 1 sfp p ort; built in power supply; , 1527283025- 4 port web managed poe+ layer2 switch for cctv camera; numbe r of 1g poe port= 4 nos. ; , 1527283026- 32 channel 4k nvr having 2 sata hdd (10tb each) port; suppor t multi brand camera; 1 x v , 1527283027- 16 channel 4k nvr having 2 sata hdd (10tb each) port; suppor t multi brand camera; 1 x v , 1527283028- 8 channel 4k nvr having 2 sata hdd (10tb each) port; support multi brand camera; 1 x vga , 1527283029- single mode full duplex auto sensed fiber media converter ha ing speed 1000 mbps; 1 rj45 , 1527283030- surveillance hard disk drive 8tb (make: wd, seagate, toshiba or equivalent any reputed m , 1527898028- hdd 6tb (make: wd/seagate)
Tender For corrigendum : tender for supply of specific instrument spares for 1 and 3 kg vffs packing machine : : - strainguage loadcell alluminium 10kg synapsis p.no-ebqj10100010000 detail specifications as per s.n. 1 of the specification document , camozzi double acting cylinder diameter 20x stroke 50 p.no-bcpbo1325120810 detail specifications as per s.n. 2 of the specification document , photomark 10-30vdc , 9.5 mm range , 3 mt cable tlu 11 datalogic , p.no-eaeb11000200000 detail specifications as per s.n. 3 of the specification document , photoelect diffuse reflective m18 , pnp , pa18csd04pasa-5m , p.no-eaka12 480000000 detail specifications as per s.n. 4 of the specification document , 4 channel temp cntrl ssr o/p , 12-24 vdc , rs485 , tm4-n2sb , p.no-eagr88451020000 detail specifications as per s.n. 5 of the specification document , slot sensor sr-21-ir , pnp/npn , no , wt 5mtr cable , data sensor , p.no-ebgf 15231110000 detail specifications as per s.n. 6 of the specification document , hmi 7 colour touchscreen , hmigxu3512/hmiet6400 , schneider , p.no-easeo3210100000 detail specifications as per s.n. 7 of the specification document , hmi 7 inch tft lcd touchscreen eth , 24vdc(dop-107mv) , delta , p.no-easb03111220000 detail specifications as per s.n. 8 of the specification document , plc exp modue , 42di/o , 24vdc , pnp tr , tm258lf42dt schneider , p.no-ebceo1100211600 detail specifications as per s.n. 9 of the specification document , plc expansion module , 12 tran output , tm5sdo12t , scheider , p.no-ebce02000111600 detail specifications as per s.n. 10 of the specification document , weight transmitter module si-01 for loadcell synapsis , p.no-eaao27020000000 detail specifications as per s.n. 11 of the specification document , plc m241 , 14di/10do 4hsc/4pto , eth , 24vdc , tm241cec24u , schneider , p.no-ebce01060821694 detail specifications as per s.n. 12 of the specification document , output module , tm3 , 160/p , 24vdc , tm3dq16tg , schneider , p.no-ebce38000211696 detail specifications as per s.n. 13 of the specification document , relay 4 relay module with 2 c/o each , din rail precise , p.no-ecdeo3000022100 detail specifications as per s.n. 14 of the specification document , modified vibrator controller for int ewf pj make , p.no-eaac25088000000 detail specifications as per s.n. 15 of the specification document , festo double acting cylinder dsnu-16-25 pa(19199) , p.no-bcpao1206120605 detail specifications as per s.n. 16 of the specification document , camozzi double acting cyl dia32xstroke 20 p.no 31f2a032a020 , p.no-bcpb13441221004 detail specifications as per s.n. 17 of the specification document , rod type sensor , p.no-a271100013ah99c detail specifications as per s.n. 18 of the specification document , photoelectric sensor model-bup-30-p , autonics , p.no-ebgg15522220000 detail specifications as per s.n. 19 of the specification document , camozzi-qnia32a10 single acting cyl-dia 32 stroke 10 , p.no-bcpb07412211002 detail specifications as per s.n. 20 of the specification document , knife for sprint plus , p.no-ao79977472ab990 detail specifications as per s.n. 21 of the specification document , camozzi 31m2a025a080 double act cyl magn dia25x80u-25-32 , p.no-bcpb13441120916 detail specifications as per s.n. 22 of the specification document
Tender For corrigendum : supply of system spares for work stations/large video screens of ucb - 2 tb portable external hard diskseagate make/hitachi/western digital , 1 tb portable external hard disk sea gate , optical mouse 3 button scrool , mouse pads of good quality of comfort make , compact disk,cd`s (moser bear) , dvdrws with cover,sony , battery,cmos , usb –make: dell ( normal keyboard ) , vga cords for desktop computers , network crimping tool (rj11&rj45) , pen drive,128gb , pen drive,256gb , nec ea244wmi-bk led monitor-24" display , hard disk 500gb ssd(internal) , hard disk 250gb ssd(internal)
Tender For corrigendum : purchase of sports exercise physiology lab equipments - cardiopulmonary exercise testing system (including treadmill & cycle ergometer) (2 years warranty)(pac), portable telemetric metabolic analyzer for field and laboratory use.metabolic analyzer portable telemetric system for metabolic analysis should have the following specifications:designlatest generation, single body - weather and dust proof to suit our requirement of tough testing conditions. it should operate in standalone, holter and direct connection to pc modes.weight on subjectless than 1 kg including battery and ergonomically designed multi-size adjustable harnesstesting capabilitypulmonary gas exchange (vo2, vco2), vo2 max, sub-max vo2, thresholds (at, rcp), heartrate with hr belt, resting energy expenditure (ree, rmr), indirect calorimetry w/ face mask, substrates analysis (rq, %fat, %pro, %cho)analysis method breath by breathmotion sensorsinbuilt gps, altimeter, accelerometer (3d + 8g range), gyroscope (3d + 2000 o/s range) andmagnetometer/compass (3d + 1000 t range)wireless connectivitywireless data transmission: bluetooth 2.1 + edr class ii (range >900 meters line-of-sight)connectivityusb, audio, heart rate (aux), wireless device interface (bluetooth for integration with compatible optional peripherals like spo2, ecg etc.)data storagestorage: 512 mb flash > 2,000,000 breathsadditional: sd-hc card 32gb/fat32 - internal slot user accessibledisplay lcd: 3.5 lcd transflective colour - high visibility with led-backlit tfttouch-screen: resistive technology, that allows gloves and wet fingersanalysersoxygen: gfc 0-25% range, lifespan approximately 12 months (very easily user replaceable) response time 120 mscarbon-dioxide: digital ndir 0-10% range, response time 100 msbarometer: range -600 to +5500mflowmeter: bi-directional digital turbine ventilation range 0 to 300 l/min powerbattery: rechargeable li-ion smart battery w/ lcd charge status indicator. 2 packs backup battery: embedded to allow main battery replacement during testing without loss of datamain: 100-240v ac/dc adapter, for direct/main power supply and battery charging. essential accessories / consumablesthe system should be supplied with a compatible treadmill and ergo cycle as per specs below. list of standard items supplied and details of consumables including o2 sensor with their life span should be provided. a compatible laptop pc, colour deskjet printer, 3 litre calibration syringe & calibration gas mixture cylinder with regulator should be supplied with the systemquality assurancemust have european ce, us fda and iso certifications. treadmill running machine with user terminal (display & keyboard) stand- alone and remote control with cpet via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 300 kg (660 lbs) speed range: 0-25 km/h elevation: 0 to 28% reverse belt rotation motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v - belt, very quiet operation safety arch should be provided with harness of 5(five) different sizes (small to large) safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10 to +40 degrees c, humidity 30 to 70% display: touchscreen display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs para control software for pc must have ce certificationergo cycle functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat adjustment easy to control and calibr
Tender For corrigendum : purchase of sports physiotherapy lab equipments - focused shockwave therapy, the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touchscreen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high power laser thera, it should have class iv laser solid-state it should have inbuilt protocol for different indications laser wavelength should be 808nm & 980nm for 18w it should provide laser power up to 0.500mw to 18w pick power 18w (808 nm wavelength for 8w & 980 nm for 10w) the unit should have 7 touchscreen facility for use the unit should operating mode should be cw (continuous) or pulsed the unit supply with attachments: scanning laser applicator 500-550mw (class 3b) the unit supply with small and large attachments 1cm and 5cm should be provided to cover different areas the unit supply with dila (deep intratissue laser adapter) supply 2 pairs of laser protective goggles to be supplied warranty 2-year class iv laser therapy is a recent modality that is used to treat pain and promote healing of muscular tissue. the class iv deep intratissue laser therapy machine is european ce approved and is clinically proven to reduce inflammation, reduce pain and increase overall range of motion in a short therapy cycle. it is being used widely all musculoskeletal pain conditions, soft tissue injuries and a wide range of other clinical indication cdsceo device registration certificate unit supply with original trolley, combination therapy machine with vaccum, the unit should be 7 colour display with touch panel treatment encyclopaedia electrodiagnostic i/t curve number of built-in programmes 204 number of user programs 150 number of compatible 2 ultrasound heads electrotherapy parmenter 2 channel electrotherapies max constant current inpatients circuit cc mode- 10. galvanic current 40 ma diadynamic, pules, current 60 ma interferential, kotz, current, unipolar sing surge -100ma tens and sp-tens current 140 ma tonolysis 100 ma microcurrents 1000 a max. voltage in patients circuite (cv mode)-140 v treatment timer 30s 60 min. the unit ultrasound head amplitude- max. 8w for 4cm head working in continuous mode the unit ultrasound head max 12w for cm working in pules mode ultrasound therapy parameter operation frequency- ultrasound head with acoustic working frequency of 1mhz & 3.5mhz with the effective radiation area 4cm effective radiating area- 4cm max ultrasound intensity -continuous /pulse mode 2/3w/cm frequency in pules mode- 16 hz/48 hz/100 hz 24. duty factor in pulse mode 5-75%, step 5% thermal effect 2-year warranty ce european or fda usa certified with iso medical device certifications cdsceo device registration certificate unit supply with original trolley and gel bottle stand and vacuum cup stand with electrode, low frequency electro magnetic therapy, 7 colour touchscreen peration mode: program/manual a sensory indicator of the magnetic field activity- magnetic stripes treatments in dual mode setting the frequency range of the magnetic field with an accuracy of 0,01 hz using the on- screen keyboard illustrated encyclopa
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - stirrer- the stirrer should be made up of ceramic coated aluminium alloy top with digital speed and temperature control. the stirring speed should be 50-1500 rpm or better. the stirrer should be operational up to a temperature range of 300oc with an accuracy of 1.0oc and ip 42 protection class. the input power should be 600 w or above. the stirrer should be supplied with hemispheric bowl (100 ml= 1 no; 250 ml= 1 no) to replace oil baths and mantles in order to perform clean and safe analysis with round bottom flasks.warranty must be one year., electronic balance- the electronic balance should have a maximum weighing capacity of 200 g or more with a resolution and repeatability of 0.1 mg, and a response time of 5 sec or better. the system should have automatic internal calibration with touchscreen display. the system should have internal database capacity of 2500 or more with multiuser password protection feature. warranty must be one year., vaccum pump - the pump should be operational at a maximum power of 65 w or more with a max. vaccum of 99 mbar or more. the pump should be fitted withvacuum and filter cartridge., hot air oven- the inner chamber should be made of stainlesssteel and the outer chamber should be m.s powdercoated. the maximum capacity of the oven shouldbe 100 ml or more. the operational temperatureshould be between ambient to 250oc or more witha temperature accuracy of 1o c. pid based digitaltemperature control., double distillation unit- the unit should be pyrogen free with a distillation water output capacity of 1.5 l/h. the minimum cooling water requirement should be 1lt/min. auto-power cut facility in case of halted supply of water., circulating oil bath- the oil bath should be made up of stainless steel with 4 digit 7 segment led display for temperature and time. the bath should have s.s perforated tray for holding flasks. the bath should have a capacity to accommodate flask of 1l. the working temperature range should be +5 to 240oc (0.1oc increment) with a temperature stability of 1oc, water bath- the water bath should have a capacity of 20 l within built water level sensor. the bath should be made up of stainless steel and supplied with 8 concentric rings. the bath should have digital temperature control with pt100 sensor. the system should have stirring capability with ptfe magnetic bars., ph/ condutivity meter - operational between a ph range of -2 to 16.00 with a resolution of 0.01 ph and an accuracy of 0.02 ph. 5 points calibration. the ec range shouldbe in between 0.00 to 29.99 s/cm, uv cabinet- operational at two uv wavelengths (254 and 365 nm). the cabinet should also be equipped with one visible light. the external body should be coated with ms powder/epoxy., flame photometer- application: the flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flametemperature. these metals include na+, k+, ca2+, ba2+ and li2+.specification requirementmeasuring range na+: 0 to 99.9 ppm k+:0 to 99.9 ppm ca 2+ :0-99.9 ppmli 2+: 0 to 99.99 ppmsensitivity na+= 0.1 ppmk+ = 0.1 ppmspecificity less than 0.5% interference when concentrations are equal to test sample concentrationsgas control-adjustable with knobsignition system-auto ignition systemflame failure-auto detectiongas cut off-automaticreproducibility-less than 1% coefficient of variation for 20 consecutive samplesusing 10 ppm na set as maximum standardlinearity-less than 1%display led, 12.5 mm (1/2")fuel supply-high-grade propane/butane mixture regulated at approximately30 psiair supply-6 l/min at 12 psi; oil and moisture freerecorder-output 0.05 to 5 v (switchable)operating manuals, service manuals, other manuals should provide user, technical and maintenance manuals in english language list of equipment and procedures required