Web Analytics Made Easy - StatCounter

Toughened Glass Tenders

Get complete information related to latest Toughened Glass Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Toughened Glass Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Toughened Glass Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45728531 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supply of toughened glass floor spring bottom and top [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45737698 Due date: 05 Aug, 202605 Aug, 2026 NA
Tender For supply of led rechargeable flood light 50 watt having die cast aluminium enclosure & ms epoxy coated structure, designed for max efficiency /rugged construction with toughened glass & water proof protection ip65, highly reliable lithium ion battery with battery backup of 4 hours in normal mode, 8 hours in low mode & 2 hours in turbo mode. high power industrial, service value 50000 hours, cri > 80%, cct 6500k, heatresistance and toughened glass, thermal management design for nest thermal life with metal mounting bracket, adjustable beam light direction & ac charger with one-year warranty. preferred make -mimic, wipro, philips, fos, oreva.or equivalent. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45732005 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For supply of bus type window assembly with sliding shutter for non-ac coaches glass set as per drg no. judw/mech/19-695. item no.3 (sliding glass shutter 5 mm toughened glass lh)-qty 1 no., item no.4 (sliding glass shutter 5 mm toughened glass rh)-qty 1 no. & item no. 5 (fixed glass shutter 5 mm toughened frosted glass)-qty 1 no. is required in 1 set, material specification as per is:2553 as mentioned in drg. no. judw/mech/19-695 [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

State Government

CTN :45734816 Due date: 16 Jul, 202616 Jul, 2026 1.14 Lacs
Tender For re-invite-providing and fixing toughened glass door at entry in department of microbiology at iind floor cbt building mdu rohtak

corporations/Associations/Others

CTN :45484915 Due date: 03 Jul, 202603 Jul, 2026 1.06 Crore
Tender For corrigendum : supply of front liminated glass flate , front liminated glass curved , toughened glass flate , toughened glass curved , window glass flate , window glass curved

State Government

CTN :45722922 Due date: 15 Jul, 202615 Jul, 2026 2.45 Lacs
Tender For supply of urchages sanitation material - alum, sanitizer, painting brush 4'', painting brush 6'', sgsv pipe (ceramic pipe 2.50x8), aggregate mix, iron rods (all sizes), iron nails (all sizes), iron angle, iron flat bar, cement sheet (8 ft long), steel mosquito mesh (3 x 1/2 width), chain-link fencing mesh (5 ft width), iron sheet (16 mm), iron pipes (all types), toughened glass (2.6 x 2 ft size), steel tap, kangaroo hp-45 large stapler

Central Government/Public Sector

CTN :45709067 Due date: 18 Jul, 202618 Jul, 2026 45.00 Lacs
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be

corporations/Associations/Others

CTN :45647769 Due date: 02 Jul, 202602 Jul, 2026 71.65 Lacs
Tender For corrigendum : maintenance and toughened glass partition/electrical /camc of it and furniture work at ekn , new delhi

Central Government And Public Sector

CTN :45728544 Due date: 16 Jul, 202616 Jul, 2026 NA
Tender For supply and fitment of all new toughened glass with rubber bit in three numbers 40/15ton eot crane (in sms) of their operators cabin at rail wheel plant/bela. (note: 03 set glass consists 60 nos. of glasses.) make: vitra tuff or similar note:- as per detailed specification given in annexure- a, rough measurement is for reference only. firm has to develop detail drawing and final measurement of the item as per sample and furnish along with supply of material. [ warranty period: 12 months after the date of delivery ]]

CTN :45678586 Due date: 08 Jul, 202608 Jul, 2026 5
Tender For corrigendum : supply of toughened glass visitor segregation system 10 mm , toughened glass access door 8 mm , door hardware channel rollers handles and accessories , frosted privacy film on glass surface , mdf finishing components and rafters , aluminium door with hydraulic door , artificial grass foot mat 40 mm , four seater work station rectangular , acrylic appointment board , installation fitting commissioning consumables and finishing
 Loading, Please wait...

Connect us via What's Up