Tender For supply of as per boq d d - main lt panel indoor type with fp ai high safety mode technology , apfc capacitor panel 1250 kvar indoor type with aluminium tp , vacuum circuit breaker panel 11 kva 800 amp and vcb panel , transformer 3500 kva input voltage 11 kv output voltage 415 v , earthing arrangement copper plate earthing with 50 kg of chemical earthing transformer - 3500 kva technical specification- 1- capacity : 3500 kva, 2- input voltage : 11 kv, 3- output voltage : 415 v, 4- number of phase : 3 phase 5- applicable standard : standard, 6- number of winding : 02 nos, 7- installation type : outdoor, 8- cooling type : onan, 9- terminal arrangement : bare, bushing for hv side & 10- cable box for lv side., 11- vector group : dyn 11, 12- ambient temperature : 50 c, 13- temperature rise of oil : 40 c, 14- temperature rise of winding : 45 c, 15- impedance : 6.25% (subject to +/-10% tolerance), 16- transformer oil : "a grade" tested & certified as per is:335 standard., 17- no load losses : as per is standard, 18- full load losses : as per is standard, 19- copper : pure electrolytic grade, 20- tapping mode 01 nos - rotary type off circuit tap changer (octc) with locking arrangement & tap indication., 21- basic insulation leve for hv : 75 kv peak / 28 kv rms, 22- basic insulation level for lv : - / 3 kv rms, 23- tapping range +5% to -5% in steps of 2.5% by off circuit tap changer (octc)., (a) earthing arrangement (1) copper plate earthing 600x600x6 mm with 50 kg of chemical compound depth around 10 meter with testing pit. (2) gi plate earthing 600x600x6 mm with 50 kg of chemical compound depth around 4 meter with testing pit. (3) copper strips 50*6 (4) gi strips 50*6 make premium, (b) cables and accessories (1) 3 c x 240 sqmm al armoured ht cable (2) joint kit (3) 3.5 c x 400 sqmm al ) /bid number : gem/2025/b/6768705 * /dated: 17-10-2025 & & / bid document 1 / 19
Tender For supply of terminal bushing along with terminal stud for 3.3kv bbc, italy make mp307 motor type: equny500pa6 as per attached specification and drawing material of construction: epoxy resin, terminal bushing for 3.3kv, crompton motor mk3301, mk3901/2/3/4/5, frame -khmac500, 560, terminal stud for 415v ngef make mp401 motor type:eamw 280m4h1ex as per attached specification and drawing material of construction- copper, terminal bushing for 415v ngef make mp401 motor type:eamw 280m4h1ex as per attached specification and drawing material of construction: epoxy resin, terminal bushing along with terminal stud for 3.3kv kirloskar make xg301 motor frame-empa560hcspl, as per attached specification and drawing material of construction: epoxy resin, insulater ekv 5025 for hv switch board mfgr and ven: ngef bangalore fo r amm:(e).
Tender For supply of mine line acb vcb tsu gate end box d d - fixed contact breaker 400a 11 06 04b , fixed contact for isolator 200a 05 01 03 , glass fuse with holder bogf , ct for ol lat1005 , current transformer for ol lat3005 , current transformer for ol lat4005 , isolator micro switch assembly 05 05 00 , earth leakage relay 50 750ma with time lag with cbct elm7lat s 80m , glass fuse with holder bogfh , cover bolts 000110a , cover bolts 000110h , indicating lamps lab9acb , overload assembly breaker 30a 100 a 11 01 00a , incoiming gland g1 , shunt trip coils 11 09 03 , push button actuator for el test boes2 , core balance transformer cbt80m , power cable for 400 a for breaker chamber ic and og set iccb4 , fault imposing relay without base booen3r , power cable for 300 a for breaker chamber ic and og set iccb3 , core balance transformer cbt70m , terminal bushing with insulator dmc incoiming 8 mm x 25 mm t5 , no volt coil assly under voltage assly with moulding 11 04 00a , current transformer for ammeter 120 300 5 5 , thermal overload relay 12 00 21 , potential transformer ds1 , on delay timer 135 30 on , aux contactor 220v ac boca2dn1229 , indiciating lamp with pcb mouting lab9 geb , on off rev isolator 300a k4r , resistance 139 geb , current trasfoemr for o l 15va 120 200 5 15 , on off isolator 400 a k4s , on off rev isolator 200a k3r , isolator 3 p on off k3 , vcb shunt trip coil 50 05 00 , potential tranformer 3 point 3kv htptl1 , earth leakage 50 750ma and 750ma 2a dual setting with time lag with cbct elm7dlat s 80m , control relay 110v 135 110 , indicating lamp lab9 tsu ht , vcb closing coil 50 10 00 , neutral monitoring relay with resitance nrmr , bullet pin 3 point 3kv bobp3 , voltmeter 600 for tsu lt 130 v 0 600 sotlt , core balance transformer cbt90m , hrc ht pt fuse boabwna , aux contactor mcra022a7 , vacuum interrupterbevoo53 , ht bushing htta3 point 3 , reset push button contact element no nc boes1 , earth leakage 50 750ma and 750ma 2a dual setting with time lag elm7dlat s , hv bushing httc , multicore bushing mcb9 , current trasformer bo400 5ctr , test off run selector switch bosrp137b , aux. transformer single phase ptfx , auxiliary contactor with coil boca2dn1229 , current transfomer 60 5 15va120 60 5 15 , current transfomer120 100 5 15 , ht bushing with stud 3 point 3 kv htta 3 point 3 , ht hrc pt fusebossabwna , indicator panellab9 3 point 3kv , miniature circuit breaker bosp6 , overload relay magnatic olr3 , resistance 06 05 08 , vacuum contactor 3 point 3 kv bevoo61 3 point 3 , current transfomer coil 110 v dc indigenous bevoo49 , copper terminals with dmc bushingt5 , no actuator boes2 , nc actuatorboes3 , isolator handle h9 , hrc fuse 16 amp 138 16 , hrc fuse 63 amp 138 63 , earth leakage 50 750ma with time lag elm7lat s
Tender For auction sale of depot non ferrous scrap - scrap non ferrous copper components consisting of flexible shunt & mobile contact lever assly for epc, shunt for c-145, finger contact & flexible shunt for reverser 1500 amps, tips with silver & without silver, connection plate, bushing stud, palm clamp of different type of transformer conventional loco bushing. bus bar, rps link patti, rf link patti, l clamp, earthing shunt conventional loco bushing, differents copper parts of equipments with or without silver attachment, set of contact ring for tap changer n-32 (one set consist 02 item 02 nos), all the released item of rs (shunting resistance) of conventional loco such as bus bar, rps link patti, rf link pattati, l clamp, sl pg clamp, roof insulator copper clamp, venting tube pipe, vcb d/b side copper patti, earthing shunt released, unserviceable defective a0-a1, a7,a8 bushing, a3, a4 bushing rf link patti, gr contact segment, gr connecting terminal unserviciable & defective released from a.c. loco. total weight = 3.150 mts approx. (silver weight = 1.16 kg. copper wight = 3148.84 kg) for custodian information ss-11- nkj/trs/scnf/25-26/18, dt 29/09/2025 ds-8 note no.-020701 date 01/10/2025. mode of delivery by actual weight only.
Tender For supply of set of 36 kv hv bushing for a34 terminal of loco transformer as per elw drg. no. elw/bsl/3/f91.053 and elw/bsl/2/94. 092 (one set consists of 10 items 11 nos.)
Tender For supply of outdoor type , plinth mounted, distribution transformer, minimum energy efficiency level 3 of rating 250 kva, 3-phase, 11kv/415-240v,50hz, oil immersed, non sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled transformer, conforming to is 1180 (part1):2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest with condition that drain-cum-sampling valve. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 f) of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides bushing appropriate voltage and current ratings., low voltage side cable end box required . the high voltage bushings (3 nos.) shall conform to is/ iec 60137. the low voltage bushings (4 nos.) shall conform to is 7421. off-circuit tap changer (applicable for all ratings above 200 kva) for variation of hv voltage from +5% to -10% in steps of 2.5%. following has to be submitted by supplier along with supply of material: (i) type test report of transformer having same rating, make (& model if any) and design from nabl accredited lab as per is: 1180 (part 1) latest. (ii) routine test certificates as per is: 1180 (part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d) & (e) of is:1180 (part 1) latest.