Get complete information related to latest Track Transformer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Track Transformer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Track Transformer Tenders.
Tender For supply of transformer module primary voltage (pos no 224.2) as per clw spec no clw/es/3/0083 al t- b and abb document no- 3ehp590547r0001 . clw drg no- clw/es/3/sk1/0083 alt-b as per drg.no. c lw/es/3/sk1/0083 alt-b as per specn. clw spec no clw/es/3/0083 alt- b [ warranty period: 30 month s after the date of delivery ]
Tender For 100a hrc fuse link (low voltage fuse), din type, rated voltage 500v ac, breaking capacit y-100ka, suitable for use in secondary side of 60kva transformer & local main supply of lhb ac coaches, confirming to is: 13703 pt-2 & rdso specification no. rdso/pe/spec/ac/ 0184-2015 (rev.-1). accepted make & cat nos.: -as per sr. no. 8 & 34 of common bom of rdso letter no. el/7.1.108/mssbc dated 17.0 9.21 or any other make with prior approval of rdso. [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ]
Tender For 100a hrc fuse holder, suitable for use in 60 kva transformer secondary and l ocal main supply, rated voltage -500v ac, breaking capacity-100ka, as per sr. no. 8 of bom (b ill of material) of rdso specification no. rdso/pe/spec/ac/0184-2015 (rev-1) and conforming to rdso specification no. rdso/pe/spec/ac/0184-2015(rev-1). accepted make & cat no: as per s r. no. 8 and 34 of rdso letter no el/7.1.108/mssbc dated 17.09.21 (i.e. siemens make cat. no. - 3 nh30300rc, abb make cat no. - 1sca833001r2001, wohner cat no.-03760 make, bussman cat n o.- sb00pb, l&t make cat no. sk90405) or any other rdso approved make. [ warranty period: 3 0 months after the date of delivery ]
Tender For supply of outdoor type , plinth mounted, distribution transformer, minimum energy efficienc y level 3 of rating 500 kva, 3-phase, 11kv/415-240v,50hz, oil immersed, non-sealed type (transformer ta nk body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (ve ctor symbol- dyn11), onan cooled transformer, conforming to is 1180 (part1):2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest with condition that drain-cum-sampling valve. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 f) of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides bushing appropriate voltage and current ratings., low voltage side cable end box required. the high voltage bushings (3 nos.) shall conform to is/iec 60137. the low volt age bushings (4 nos.) shall conform to is 7421. off-circuit tap changer (applicable for all ratings above 20 0 kva) for variation of hv voltage from +5% to -10% in steps of 2.5%. following has to be submitted by su pplier along with supply of material: (i) type test report of transformer having same rating, make (& mode l if any) and design from nabl accredited lab as per is: 1180 (part 1) latest. (ii) routine test certificates as per is: 1180 (part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d) & (e) of is:11 80 (part 1) latest. supply of outdoor type , plinth mounted, distribution transformer, minimum energy effici ency level 3 of rating 500kva, 3-phase, 11kv/415-240v,50hz, oil immersed, non-sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star ( vector symbol- dyn11), onan cooled transformer, conforming to is 1180 (part1):2014 with amendment n os. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) late st with condition that drain-cum-sampling valve. oil temperature indicator & winding temperature indicato rs will be provided as per clause 20.2 f) of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides bushing appropriate voltage and current ratings., low volta ge side cable end box required. the high voltage bushings (3 nos.) shall conform to is/iec 60137. the low voltage bushings (4 nos.) shall conform to is 7421. off-circuit tap changer (applicable for all ratings above 200 kva) for variation of hv voltagefrom +5% to -10% in steps of 2.5%. following has to be submitted by s upplier along with supply of material: (i) type test report of transformer having same rating, make (& mod el if any) and design from nablaccredited lab as per is: 1180 (part 1) latest. (ii) routine test certificates a s per is: 1180 (part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d) & (e) of is:1 180 (part 1) latest. [ warranty period: 30 months after the date of delivery ]
Tender For supply of fuses , rheostat sliding type , capacitors , various electronic components , various lamps , plug socket piano switch , cables , bus bar with brackets , rubber mat , electrician helmet , rcc pole with accessories , safety belt , ohm meter series type shunt type portable box type , digital multi meter , a.c. voltmeter m.i. analog, portable box type housed in bakelite , milli voltmeter centre zero analog, , ammeter mc analog, portable box type housed in bakelite case , ac ammeter mi, analog, portable box type housed in bakelite case , kilo wattmeter analog , digital wattmeter , a.c. energy meter , power factor meter digital , frequency meter , magnetic flux meter , lux meter , tachometer , tong tester clamp meter , megger , 3- point d.c. starter , 4- point d.c. starter , wheat stone bridge with galvanometer and battery , single phase variable auto , phase sequence indicator , growler , ac starters , oscilloscope dual trace , function generator , soldering iron , temperature controlled soldering , discrete component trainer , linear i.c. trainer , digital i.c. trainer , domestic appliances , oil testing kit , inverter with battery , voltage stabilizer , dc power supply , battery charger , current transformer , potential transformer , solar panel with battery , d.c. shunt generator with control panel , motor- generator ac to dc , d.c. compound generator with control panel including fitted rheostat, voltmeter, ammeter and breaker , dc series motor coupled with spring balance load , dc shunt motor , dc compound motor with starter , motor generatordc to ac set consisting , ac squirrel cage motor with star delta , ac phase-wound slip ring motor with starter switch , universal motor with starterswitch , synchronous motor with accessories like starter, excitation , thyristor igbt controlled d.c. motor drive with tacho-generator , thyristorigbt controlled a.c. motor drive with , single phase transformer, core type, air cooled , three phase transformer, shell type oil cooled with delta star , electrical machine trainer , diesel generator set with changeover switch over cut , used dc generators-series, shunt and compound type for overh , pillar electric drill machine motorized , motorised bench grinder , a.c. series type motor , single phase capacitor motor with , manual motor coil winding machine , ceiling fan coil winding machine , primary current injection set , stepper motor with digital controller , shaded pole motor , smart meter , ev charger , ev charger home , wiring board , metal rack , black boardwhite board , fire extinguisher co2 , fire buckets
Tender For supply of electrical lab equipment - digital multimeter , stop watch digital , connecting leads , 4mm to 4mm double point patch chord for inter-connection leng 15 inches , alligator clips , dc ammeters (0-1,2,5,... 10 amps (internal shunt) (select any on range) , wattmeter 0-75w , wattmeter 0-150w , rheostat various ranges , rheostat 300 ohms / 2 amp , rheostat 100 ohms / 5 amp , rheostat 50 ohms / 5 amp , rheostat 250 ohms / 3 amp , rheostat 10 ohms / 10 amp , resister inductor capacitor of different value (ohm.k ohm,mh,mf 10 each (set of 30) , auto transformer 1kva , lcr impedance apparatus with bakelite panel & round meters , wires , circuit kit for verification of superposition theorem , circuit kit for verification of thevenin's theorem , circuit kit for verification of norton's theorem , circuit kit for verification of maximum power transfer theorem , kelvin bridge (industrial) with dc source & galvanometer kelvin's double bridge designed 20000 6 120,000 bridge test kit compact, pottable kelvin double bridge designed , dc potentiometer kit with 12v d.c standard cell , ammeter 0-5a , ammeter 0-10a , voltmeter 0-300v , voltmeter 0-600v , single phase & three phase energy meter testing kit , rheostat various ranges , rheostat 300 ohms / 2 amp , rheostat 100 ohms / 5 amp , rheostat 50 ohms / 5 amp , rheostat 250 ohms / 3 amp , rheostat 10 ohms / 10 amp , dc shunt generator along with dc motor as prime mover with control panel , dc series generator along with dc motor as prime mover with control panel , dc shunt motor 3hp 220v 1500rpm with control panel with control panel , dc. shunt motor mechanical braking arrangement with control panel , dc series motor 3hp 220v 1500rpm with mechanical braking arrangement with control panel , three point dc motor starter 0-220v 0-10a , four point dc motor starter 0-220v 0-10a , dc voltmeter 0-230v dc , dc ammeter 0-10a , single phase transformer 230/230v,230/115v,3kva with tapping at 10%,25%,50% and 75% housed in steel box with educational type terminals provided with control panel for o.c and s.c test) consists of the following accessories. , 230/230v, 230/115v, 3kva with tapping at 10%, 25%, 50% and 75% housed in steel box with educational type terminals provided with control panel. (for o.c. and s.c. test) consists of the following accessories.a) mcb (16a, 600v) – 1 pc b) fuse 10a - 1pc c) analog ammeter (0-1a) – 1 pc d) analog ammeter (0-5a) – 1 рсе) analog voltmeter (0-50a) (0-300v) – 1 pc each f) wattmeter 1/2a, 150/300v g) wattmeter 5/10a, 75/150v h) 1-loading rheostat , 3 phase transformer 400/230v y connected 10a , single phase transformer 220v/110v, 13.62/27.25a 3kva , experimental kit for overcurrent relay idmt type relay idmt type; realy test kit (current injection unit). one number of 230v ac @ 50hz ac input with power on/off switch , air circuit breaker trainer kit patch cordes 4mm (heavy duty) 1meter lengh. high voltage test point are provided with 4mm safery sockets. the trainer is housed in metal cabinet short circuit projection with the mcb.. size of the trainer set 20"x30". , miniature circuit breaker (mocb) trainer kit minimum oil circuit breaker (mocb) trainer kit , specification: alternator , of 3ph, y connected 415v, skya, (mg -sct) , 0.8 pf, 50hz -. dc regulated power suply 0-30v, 2 amp with digital voltmeter and ammeter , miniature circuit breaker (mcb) trainer kit alphanumeric 16x2 big font lcd for better visibility isolated power supply using transformer in built variable current injection facility transparent mcb's to understand internal architecture and its working inbuilt timer, current & temperature in lcd mcbs are mounted with tempetature sensor for current temperature analysis equipped with supply indication lamp , sf6 (sulphur hexa fuoride circuit breaker trainer kit) 440volts, 3 phase 4 wire 50hz, , vacuum circuit breaker trainer kit 11kv, 800a, draw out version, motor operated spring charging with electrical and manual operation provision
Tender For supply of electrician screwdriver thin stem insulated handle , knife double bladed electrician , neon tester , blow lamp brass , crimping tool , wire cutter and stripper , copper bit soldering iron , de soldering gun , contactor & auxiliary contacts , contactor & auxiliary contacts. , limit switch , rotary switch , cut out relays , reverse current , over current , under voltage , pin type, shackle type, egg type & suspension type insulators including hardware fitting , hydrometer , portable electric drill machine , load bank ( lamp / heater type) , laboratory type induction coil , out side micrometer , knife switch dpdt fitted with fuse terminals , knife switch tpdt fitted with fuse terminals , earth plate , earth electrode , mccb , elcb , rccb , fuses , rheostat (sliding type) , capacitors , various lamps , bus bar with brackets , rubber mat , electrician helmet , safety belt , ohm meter; series type & shunt type, portable box type , digital multi meter , a. c. voltmeter m. i. analog, portable box type housed in bakelite case , milli voltmeter centre zero analog, portable box type housed in bakelite case , ammeter mc analog, portable box type housed in bakelite case , ac ammeter mi, analog, portable box type housed in bakelite case , kilo wattmeter analog , digital wattmeter , a. c. energy meter , power factor meter digital , frequency meter , magnetic flux meter , lux meter , tachometer , tong tester / clamp meter , megger , 3- point d. c. starter , 4- point d. c. starter , wheat stone bridge with galvanometer and battery , single phase variable auto transformer , phase sequence indicator , growler , resistance type starter , direct online starter , star delta starter- manual , star delta starter semi automatic , star delta starter fully automatic , star delta starter - soft starter , auto transformer type , oscilloscope dual trace , function generator , soldering iron , temperature controlled soldering iron , discrete component trainer , linear i. c. trainer , digital i. c. trainer , electric induction plate , electric kettle , electric iron , immersion heater , a. c. ceiling fan and ac table fan , geyser (storage type) , mixture & grinder , washing machine semi-automatic , motor pump set , inverter with battery , voltage stabilizer , dc power supply , battery charger , current transformer , potential transformer , solar panel with battery , ink jet/ laser printer , dc compound motor with starter and switch , thyristor /igbt controlled d. c. motor drive with tacho-generator feedback arrangement , thyristor/igbt controlled a. c. motor drive with , electrical machine trainer , used dc generators- series, shunt and compound type for overhauling practice , motorised bench grinder , ceiling fan coil winding machine , primary current injection set , stepper motor with digital controller , shaded pole motor , smart meter , ev charger , ev charger (home) , portable double telescopic ladder , 3- ph variac , rotary hammer drill, 1-ph , lcr meter , manual motor coil winding machine
Tender For supply of high voltage bushing 35kv, 600a of type elastimold 750s1 suitable for 25kv 3-phase loco m ain transformer as per abb id no. hstn 420783 p0001. [ warranty period: 30 months after the date of d elivery ]